Investigation of depth dependent changes in cerebral haemodynamics during face perception in infants
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Near-infrared spectroscopy has been used to record oxygenation changes in the visual cortex of 4 month old infants. Our in-house topography system, with 30 channels and 3 different source-detector separations, recorded changes in the concentration of oxy-, deoxy- and total haemoglobin (HbO2, HHb and HbT) in response to visual stimuli (face, scrambled visual noise and cartoons as rest). The aim of this work was to demonstrate the capability of the system to spatially localize functional activation and study the possibility of depth discrimination in the haemodynamic response. The group data show both face stimulation and visual noise stimulation induced significant increases in HbO2 from rest, but the increase in HbO2 with face stimulation was not significantly different from that seen with visual noise stimulation. The face stimuli induced increases in HbO2 were spread across a greater area across all depths than visual noise induced changes. In results from a single subject there was a significant increase of HbO2 in the inferior area of the visual cortex in response to both types of stimuli, and a larger number of channels (source-detector pairs) showed HbO2 increase to face stimuli, especially at the greatest depth. Activation maps were obtained using 3D reconstruction methods on multi source-detector separation optical topography data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Specialization of Neural Mechanisms Underlying Face Recognition in Human Infants
Haan, M. D., Pascalis, O., & Johnson, M. H. (2002) · Journal of Cognitive Neuroscience · doi:10.1162/089892902317236849 · Cited by 553
Self-citation“Newborns' Preference for Face-Relevant Stimuli: Effects of Contrast Polarity”
Farroni, T., Johnson, M. H., Menon, E., Zulian, L., Faraguna, D., & Csibra, G. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502205102 · Cited by 467
Self-citationHalit, H., de Haan, M., & Johnson, M. H. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00076-4 · Cited by 338
Self-citationAslin, R. N., & Mehler, J. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1854672 · Cited by 148
Cited by
Lloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Self-citationNear-infrared spectroscopy: A report from the McDonnell infant methodology consortium
Gervain, J., Mehler, J., Werker, J. F., Nelson, C. A., Csibra, G., Lloyd-Fox, S., Shukla, M., & Aslin, R. N. (2011) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2010.07.004 · Cited by 363
Self-citationThe Developmental Origins of Voice Processing in the Human Brain
Grossmann, T., Oberecker, R., Koch, S. P., & Friederici, A. D. (2010) · Neuron · doi:10.1016/j.neuron.2010.03.001 · Cited by 310
“…in magenta, and the channel that showed increased sensitivity to happy prosody is marked in blue on the head model. at which the source of this activation is located (see Blasi et al., 2007, for NIRS methodology that allows for the measurement of depth-dependent hemodynamic responses in infants).”
Social perception in infancy: A near infrared spectroscopy study
Lloyd-Fox, S., Blasi, A., Volein, A., Everdell, N., Elwell, C. E., & Johnson, M. H. (2009) · Child Development · doi:10.1111/j.1467-8624.2009.01312.x · Cited by 217
“More complex stimuli have now been investigated using a range of different multichannel NIRS optical topography systems (i.e., Blasi et al., 2007; Otsuka et al., 2007; Peñ a et al., 2003; Shimada & Hiraki, 2006).”
BackgroundInfluentialSelf-citationThe Evolution of Social Orienting: Evidence from Chicks (Gallus gallus) and Human Newborns
Rosa Salva, O., Farroni, T., Regolin, L., Vallortigara, G., & Johnson, M. H. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018802 · Cited by 149
Self-citation
Metadata
- Authors
- Blasi, A., Fox, S., Everdell, N., Volein, A., Tucker, L., Csibra, G., Gibson, A. P., Hebden, J. C., Johnson, M. H., & Elwell, C. E.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-11-08
- Volume
- 52
- Issue
- 23
- Pages
- 6849-6864
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2056468786
- Cited by
- 63
- References
- 5
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation of depth dependent changes in cerebral haemodynamics during face perception in infants. https://app.cochat.ai/papers/10.1088/0031-9155/52/23/005
- The paper
- Blasi, A., Fox, S., Everdell, N., Volein, A., Tucker, L., Csibra, G., Gibson, A. P., Hebden, J. C., Johnson, M. H., & Elwell, C. E. (2007). Investigation of depth dependent changes in cerebral haemodynamics during face perception in infants. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/52/23/005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.