Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms
The DOI matches its Crossref record.
Abstract
The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to 100 GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication. For the calculation, the radiation and tissue weighting factors, w(R) and w(T), respectively, as revised in ICRP Publication 103 were employed. The conversion coefficients for effective dose equivalents derived using the radiation quality factors of both Q(L) and Q(y) relationships were also estimated, utilizing the functions for calculating the probability densities of the absorbed dose in terms of LET (L) and lineal energy (y), respectively, implemented in PHITS. By comparing these data with the corresponding data for the effective dose, we found that the numerical compatibilities of the revised w(R) with the Q(L) and Q(y) relationships are fairly established. The calculated data of these dose conversion coefficients are indispensable for constructing the radiation protection systems based on the new recommendations given in ICRP103 for aircrews and astronauts, as well as for workers in accelerators and nuclear facilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Particle and Heavy Ion Transport code System, PHITS, version 2.52
Sato, T., Niita, K., Matsuda, N., Hashimoto, S., Iwamoto, Y., Noda, S., Ogawa, T., Iwase, H., Nakashima, H., Fukahori, T., et al. (2013) · Journal of Nuclear Science and Technology · doi:10.1080/00223131.2013.814553 · Cited by 853
Self-citationConversion Coefficients for Radiological Protection Quantities for External Radiation Exposures
Petoussi-Henss, N., Bolch, W. E., Eckerman, K. F., Endo, A., Hertel, N., Hunt, J., Pelliccioni, M., Schlattl, H., & Zankl, M. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2011.10.001 · Cited by 721
Self-citationICRP Publication 123: Assessment of Radiation Exposure of Astronauts in Space
Dietze, G., Bartlett, D. T., Cool, D. A., Cucinotta, F. A., Jia, X., McAulay, I. R., Pelliccioni, M., Petrov, V., Reitz, G., & Sato, T. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2013.05.004 · Cited by 239
Self-citationRadiation dose to the global flying population
Alvarez, L. E., Eastham, S. D., & Barrett, S. R. H. (2016) · Journal of Radiological Protection · doi:10.1088/0952-4746/36/1/93 · Cited by 13
Description of Transport Codes for Space Radiation Shielding
Kim, M.-H. Y., Wilson, J. W., & Cucinotta, F. A. (2012) · Health Physics · doi:10.1097/hp.0b013e318266732f · Cited by 8
“Applications have been made with the most popular Monte Carlo transport codes [MCNPX (McKinney et al. 2006), HETC-HEDS (Townsend et al. 2005), GEANT4 (Adams et al. 2007), PHITS (Sato et al. 2009), FLUKA (Ballarini et al. 2007), and SHIELD (Denisov et al. 2010)].”
Method
Metadata
- Authors
- Sato, T., Endo, A., Zankl, M., Petoussi-Henss, N., & Niita, K.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2009-03-05
- Volume
- 54
- Issue
- 7
- Pages
- 1997-2014
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2094573591
- Cited by
- 86
- References
- 0
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms. https://app.cochat.ai/papers/10.1088/0031-9155/54/7/009
- The paper
- Sato, T., Endo, A., Zankl, M., Petoussi-Henss, N., & Niita, K. (2009). Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/54/7/009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.