The FLUKA Monte Carlo code coupled with the local effect model for biological calculations in carbon ion therapy
Open accessThe DOI matches its Crossref record.
Abstract
Clinical Monte Carlo (MC) calculations for carbon ion therapy have to provide absorbed and RBE-weighted dose. The latter is defined as the product of the dose and the relative biological effectiveness (RBE). At the GSI Helmholtzzentrum für Schwerionenforschung as well as at the Heidelberg Ion Therapy Center (HIT), the RBE values are calculated according to the local effect model (LEM). In this paper, we describe the approach followed for coupling the FLUKA MC code with the LEM and its application to dose and RBE-weighted dose calculations for a superimposition of two opposed (12)C ion fields as applied in therapeutic irradiations. The obtained results are compared with the available experimental data of CHO (Chinese hamster ovary) cell survival and the outcomes of the GSI analytical treatment planning code TRiP98. Some discrepancies have been observed between the analytical and MC calculations of absorbed physical dose profiles, which can be explained by the differences between the laterally integrated depth-dose distributions in water used as input basic data in TRiP98 and the FLUKA recalculated ones. On the other hand, taking into account the differences in the physical beam modeling, the FLUKA-based biological calculations of the CHO cell survival profiles are found in good agreement with the experimental data as well with the TRiP98 predictions. The developed approach that combines the MC transport/interaction capability with the same biological model as in the treatment planning system (TPS) will be used at HIT to support validation/improvement of both dose and RBE-weighted dose calculations performed by the analytical TPS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
The FLUKA Code: An Accurate Simulation Tool for Particle Therapy
Battistoni, G., Bauer, J., Boehlen, T. T., Cerutti, F., Chin, M. P. W., Dos Santos Augusto, R., Ferrari, A., Ortega, P. G., Kozłowska, W., Magro, G., et al. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00116 · Cited by 272
Self-citationStewart, R. D., Streitmatter, S. W., Argento, D. C., Kirkby, C., Goorley, J. T., Moffitt, G., Jevremovic, T., & Sandison, G. A. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/21/8249 · Cited by 103
Carante, M. P., Aricò, G., Ferrari, A., Kozlowska, W., Mairani, A., & Ballarini, F. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab490f · Cited by 23
Self-citationIn vivo validation of the BIANCA biophysical model: benchmarking against rat spinal cord RBE data
Carante, M. P., Aricò, G., Ferrari, A., Karger, C. P., Kozlowska, W., Mairani, A., Sala, P., & Ballarini, F. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21113973 · Cited by 21
Self-citation
Metadata
- Authors
- Mairani, A., Brons, S., Cerutti, F., Fassò, A., Ferrari, A., Krämer, M., Parodi, K., Scholz, M., & Sommerer, F.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2010-07-20
- Volume
- 55
- Issue
- 15
- Pages
- 4273-4289
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2058598384
- Cited by
- 104
- References
- 0
- FWCI
- 7.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The FLUKA Monte Carlo code coupled with the local effect model for biological calculations in carbon ion therapy. https://app.cochat.ai/papers/10.1088/0031-9155/55/15/006
- The paper
- Mairani, A., Brons, S., Cerutti, F., Fassò, A., Ferrari, A., Krämer, M., Parodi, K., Scholz, M., & Sommerer, F. (2010). The FLUKA Monte Carlo code coupled with the local effect model for biological calculations in carbon ion therapy. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/55/15/006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.