The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
In Vivo Validation of the BIANCA Biophysical Model: Benchmarking against Rat Spinal Cord RBE Data
Open accessAbstract
(1) Background: Cancer ion therapy is constantly growing thanks to its increased precision and, for heavy ions, its increased biological effectiveness (RBE) with respect to conventional photon therapy. The complex dependence of RBE on many factors demands biophysical modeling. Up to now, only the Local Effect Model (LEM), the Microdosimetric Kinetic Model (MKM), and the “mixed-beam” model are used in clinics. (2) Methods: In this work, the BIANCA biophysical model, after extensive benchmarking in vitro, was applied to develop a database predicting cell survival for different ions, energies, and doses. Following interface with the FLUKA Monte Carlo transport code, for the first time, BIANCA was benchmarked against in vivo data obtained by C-ion or proton irradiation of the rat spinal cord. The latter is a well-established model for CNS (central nervous system) late effects, which, in turn, are the main dose-limiting factors for head-and-neck tumors. Furthermore, these data have been considered to validate the LEM version applied in clinics. (3) Results: Although further benchmarking is desirable, the agreement between simulations and data suggests that BIANCA can predict RBE for C-ion or proton treatment of head-and-neck tumors. In particular, the agreement with proton data may be relevant if the current assumption of a constant proton RBE of 1.1 is revised. (4) Conclusions: This work provides the basis for future benchmarking against patient data, as well as the development of other databases for specific tumor types and/or normal tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 RBE as a function of carbon ion dose for irradiation of the rat spinal cord in the SOBP (upper line and filled data points) or in the entrance plateau (lower line and open data points). The lines are predictions by BIANCA, the points are experimental data taken from [10].](https://figures.cochat.ai/paper-figures/fe857d2cc4474adf8fc9e93204d697da/in-vivo-validation-of-the-bianca-biophysical-model-benchmarking-against-rat-figure-2.jpg)
![Figure 3 RBE as a function of dose-averaged LET for single-fraction (panel a) or two-fraction (panel b) irradiation of the rat spinal cord at different positions within the carbon-ion Spread-Out Bragg Peak (SOBP). The lines are predictions obtained by BIANCA, the points are experimental data taken from [12,14] (panel a), or [13] (panel b). In panel a, at 99 keV/µm the higher experimental value is from a repetition experiment [14] and is considered as more reliable.](https://figures.cochat.ai/paper-figures/a1e28c7ddb8242dab27aef222ce34cf0/in-vivo-validation-of-the-bianca-biophysical-model-benchmarking-against-rat-figure-3.jpg)
![Figure 4 RBE as a function of depth for single-fraction (panel a) or two-fraction (panel b) proton irradiation of the rat spinal cord. The lines are predictions by BIANCA, the points are experimental data taken from [15].](https://figures.cochat.ai/paper-figures/5e251cd145b54edb8793f18f4dd9f2e8/in-vivo-validation-of-the-bianca-biophysical-model-benchmarking-against-rat-figure-4.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536
Self-citationThe FLUKA Code: Developments and Challenges for High Energy and Medical Applications
Böhlen, T. T., Cerutti, F., Chin, M. P. W., Fassò, A., Ferrari, A., Ortega, P. G., Mairani, A., Sala, P. R., Smirnov, G., & Vlachoudis, V. (2014) · Nuclear Data Sheets · doi:10.1016/j.nds.2014.07.049 · Cited by 1,758
Self-citationPaganetti, H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r419 · Cited by 915
Proton therapy – Present and future
Mohan, R., & Grosshans, D. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.11.006 · Cited by 608
Computation of cell survival in heavy ion beams for therapy
Scholz, M., Kellerer, A. M., Kraft-Weyrather, W., & Kraft, G. (1997) · Radiation and Environmental Biophysics · doi:10.1007/s004110050055 · Cited by 464
Irradiation of Mixed Beam and Design of Spread-Out Bragg Peak for Heavy-Ion Radiotherapy
Kanai, T., Furusawa, Y., Fukutsu, K., Itsukaichi, H., Eguchi-Kasai, K., & Ohara, H. (1997) · Radiation Research · doi:10.2307/3579446 · Cited by 422
Elsässer, T., Weyrather, W. K., Friedrich, T., Durante, M., Iancu, G., Krämer, M., Kragl, G., Brons, S., Winter, M., Weber, K.-J., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.05.014 · Cited by 351
Cornforth, M. N., & Bedford, J. S. (1987) · Radiation Research · doi:10.2307/3576926 · Cited by 332
Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model
Inaniwa, T., Furukawa, T., Kase, Y., Matsufuji, N., Toshito, T., Matsumoto, Y., Furusawa, Y., & Noda, K. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/008 · Cited by 328
Proton vs carbon ion beams in the definitive radiation treatment of cancer patients
Suit, H., DeLaney, T., Goldberg, S., Paganetti, H., Clasie, B., Gerweck, L., Niemierko, A., Hall, E., Flanz, J., Hallman, J., et al. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.01.015 · Cited by 290
Cited by
The FLUKA code: Overview and new developments
Ballarini, F., Batkov, K. E., Battistoni, G., Bisogni, M. G., Böhlen, T. T., Campanella, M., Carante, M. P., Chen, D., Gregorio, A. D., Degtiarenko, P., et al. (2024) · EPJ Nuclear Sciences & Technologies · doi:10.1051/epjn/2024015 · Cited by 70
Self-citationThe RBE in ion beam radiotherapy: In vivo studies and clinical application
Karger, C. P., Glowa, C., Peschke, P., & Kraft-Weyrather, W. (2021) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2020.12.001 · Cited by 45
Self-citationA Mission to Mars: Prediction of GCR Doses and Comparison with Astronaut Dose Limits
Ramos, R. L., Carante, M. P., FERRARI, A., SALA, P. R., Vercesi, V. I., & Ballarini, F. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24032328 · Cited by 37
Self-citationRamos, R. L., Embriaco, A., Carante, M. P., Ferrari, A., Sala, P., Vercesi, V., & Ballarini, F. (2022) · Journal of Radiological Protection · doi:10.1088/1361-6498/ac6991 · Cited by 17
Self-citationCarante, M. P., Embriaco, A., Aricò, G., Ferrari, A., Mairani, A., Mein, S., Ramos, R., Sala, P., & Ballarini, F. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac25d4 · Cited by 15
Self-citation
Metadata
- Authors
- Carante, M. P., Aricò, G., Ferrari, A., Karger, C. P., Kozlowska, W., Mairani, A., Sala, P., & Ballarini, F.
- Affiliations
- Istituto Nazionale di Fisica Nucleare (IT)
- European Organization for Nuclear Research (CH)
- German Cancer Research Center (DE)
- CERN—European Organization for Nuclear Research, 1211 Geneva, Switzerland
- HIT (Heidelberg Ion-Beam Therapy Center), 69120 Heidelberg, Germany
- Corresponding author
- Ballarini, Francesca
- ORCID
- Venue
- International Journal of Molecular Sciences
- Publisher
- MDPI AG
- Published
- 2020-06-01
- Volume
- 21
- Issue
- 11
- Pages
- 3973
- ISSN
- 1422-0067 (ISSN-L)
- PMC
- PMC7312044
- OpenAlex
- W3030411233
- Semantic Scholar
- 881ed9e9684e53c518da1e0cef37473e9622e5f0
- Cited by
- 21
- References
- 43
- Citations by year
- 2026: 3 · 2024: 6 · 2023: 3 · 2022: 5 · 2021: 3 · 2020: 1
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- International Journal of Molecular Sciences (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Instituto Nazionale di Fisica Nucleare (MC-INFN/FLUKA)
- European Commission (Marie Sklodowska-Curie grant agreement No 675265)
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Keywords
- relative biological effectiveness, carbon ion radiotherapy, proton therapy, rat spinal cord, head and neck cancer, local effect model, FLUKA Monte Carlo simulation, heavy ion radiotherapy
- MeSH terms
- Animals, Carbon, Cell Survival, Central Nervous System, Chordoma, Cricetulus, Cricetinae, Head and Neck Neoplasms, Humans, Kinetics, Monte Carlo Method, Radiometry, Relative Biological Effectiveness, Spinal Cord, Databases, Factual, CHO Cells, Rats, Proton Therapy, Heavy Ion Radiotherapy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Validation of the BIANCA Biophysical Model: Benchmarking against Rat Spinal Cord RBE Data. https://app.cochat.ai/papers/10.3390/ijms21113973
- The paper
- Carante, M. P., Aricò, G., Ferrari, A., Karger, C. P., Kozlowska, W., Mairani, A., Sala, P., & Ballarini, F. (2020). In Vivo Validation of the BIANCA Biophysical Model: Benchmarking against Rat Spinal Cord RBE Data. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms21113973
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.