Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

In Vivo Validation of the BIANCA Biophysical Model: Benchmarking against Rat Spinal Cord RBE Data

Open access
Carante, Mario P., Aricò, Giulia, Ferrari, Alfredo, Karger, Christian P., Kozlowska, Wioletta, Mairani, Andrea, Sala, Paola, Ballarini, Francesca · 2020 · International Journal of Molecular Sciences

Abstract

(1) Background: Cancer ion therapy is constantly growing thanks to its increased precision and, for heavy ions, its increased biological effectiveness (RBE) with respect to conventional photon therapy. The complex dependence of RBE on many factors demands biophysical modeling. Up to now, only the Local Effect Model (LEM), the Microdosimetric Kinetic Model (MKM), and the “mixed-beam” model are used in clinics. (2) Methods: In this work, the BIANCA biophysical model, after extensive benchmarking in vitro, was applied to develop a database predicting cell survival for different ions, energies, and doses. Following interface with the FLUKA Monte Carlo transport code, for the first time, BIANCA was benchmarked against in vivo data obtained by C-ion or proton irradiation of the rat spinal cord. The latter is a well-established model for CNS (central nervous system) late effects, which, in turn, are the main dose-limiting factors for head-and-neck tumors. Furthermore, these data have been considered to validate the LEM version applied in clinics. (3) Results: Although further benchmarking is desirable, the agreement between simulations and data suggests that BIANCA can predict RBE for C-ion or proton treatment of head-and-neck tumors. In particular, the agreement with proton data may be relevant if the current assumption of a constant proton RBE of 1.1 is revised. (4) Conclusions: This work provides the basis for future benchmarking against patient data, as well as the development of other databases for specific tumor types and/or normal tissues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ijms21113973

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Relative biological effectiveness–Linear Energy Transfer (RBE-LET) relationship calculated by BIANCA for chordoma cell survival following irradiation with monochromatic carbon beams at 1 Gy (upper curve) or 2 Gy (lower curve) Carbon dose.
Figure 1 Relative biological effectiveness–Linear Energy Transfer (RBE-LET) relationship calculated by BIANCA for chordoma cell survival following irradiation with monochromatic carbon beams at 1 Gy (upper curve) or 2 Gy (lower curve) Carbon dose.CC BY · PubMed Central
Figure 2 RBE as a function of carbon ion dose for irradiation of the rat spinal cord in the SOBP (upper line and filled data points) or in the entrance plateau (lower line and open data points). The lines are predictions by BIANCA, the points are experimental data taken from [10].
Figure 2 RBE as a function of carbon ion dose for irradiation of the rat spinal cord in the SOBP (upper line and filled data points) or in the entrance plateau (lower line and open data points). The lines are predictions by BIANCA, the points are experimental data taken from [10].CC BY · PubMed Central
Figure 3 RBE as a function of dose-averaged LET for single-fraction (panel a) or two-fraction (panel b) irradiation of the rat spinal cord at different positions within the carbon-ion Spread-Out Bragg Peak (SOBP). The lines are predictions obtained by BIANCA, the points are experimental data taken from [12,14] (panel a), or [13] (panel b). In panel a, at 99 keV/µm the higher experimental value is from a repetition experiment [14] and is considered as more reliable.
Figure 3 RBE as a function of dose-averaged LET for single-fraction (panel a) or two-fraction (panel b) irradiation of the rat spinal cord at different positions within the carbon-ion Spread-Out Bragg Peak (SOBP). The lines are predictions obtained by BIANCA, the points are experimental data taken from [12,14] (panel a), or [13] (panel b). In panel a, at 99 keV/µm the higher experimental value is from a repetition experiment [14] and is considered as more reliable.CC BY · PubMed Central
Figure 4 RBE as a function of depth for single-fraction (panel a) or two-fraction (panel b) proton irradiation of the rat spinal cord. The lines are predictions by BIANCA, the points are experimental data taken from [15].
Figure 4 RBE as a function of depth for single-fraction (panel a) or two-fraction (panel b) proton irradiation of the rat spinal cord. The lines are predictions by BIANCA, the points are experimental data taken from [15].CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Cited by

See all 21

Metadata

Authors
Carante, M. P., Aricò, G., Ferrari, A., Karger, C. P., Kozlowska, W., Mairani, A., Sala, P., & Ballarini, F.
Affiliations
  • Istituto Nazionale di Fisica Nucleare (IT)
  • European Organization for Nuclear Research (CH)
  • German Cancer Research Center (DE)
  • CERN—European Organization for Nuclear Research, 1211 Geneva, Switzerland
  • HIT (Heidelberg Ion-Beam Therapy Center), 69120 Heidelberg, Germany
Corresponding author
Ballarini, Francesca
Venue
International Journal of Molecular Sciences
Publisher
MDPI AG
Published
2020-06-01
Volume
21
Issue
11
Pages
3973
ISSN
1422-0067 (ISSN-L)
OpenAlex
W3030411233
Cited by
21
References
43
Citations by year
2026: 3 · 2024: 6 · 2023: 3 · 2022: 5 · 2021: 3 · 2020: 1
FWCI
1.69
Type
journal article
Language
en
Open access
Locations
  • International Journal of Molecular Sciences (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • CERN Document Server (European Organization for Nuclear Research) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Instituto Nazionale di Fisica Nucleare (MC-INFN/FLUKA)
  • European Commission (Marie Sklodowska-Curie grant agreement No 675265)
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
Keywords
relative biological effectiveness, carbon ion radiotherapy, proton therapy, rat spinal cord, head and neck cancer, local effect model, FLUKA Monte Carlo simulation, heavy ion radiotherapy
MeSH terms
Animals, Carbon, Cell Survival, Central Nervous System, Chordoma, Cricetulus, Cricetinae, Head and Neck Neoplasms, Humans, Kinetics, Monte Carlo Method, Radiometry, Relative Biological Effectiveness, Spinal Cord, Databases, Factual, CHO Cells, Rats, Proton Therapy, Heavy Ion Radiotherapy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo Validation of the BIANCA Biophysical Model: Benchmarking against Rat Spinal Cord RBE Data. https://app.cochat.ai/papers/10.3390/ijms21113973
The paper
Carante, M. P., Aricò, G., Ferrari, A., Karger, C. P., Kozlowska, W., Mairani, A., Sala, P., & Ballarini, F. (2020). In Vivo Validation of the BIANCA Biophysical Model: Benchmarking against Rat Spinal Cord RBE Data. International Journal of Molecular Sciences. https://doi.org/10.3390/ijms21113973

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.