Effects of cold sphere walls in PET phantom measurements on the volume reproducing threshold

Hofheinz, F, Dittrich, S, Pötzsch, C, Hoff, J van den · 2010 · Physics in Medicine and Biology
Cited by 111

The DOI matches its Crossref record.

Abstract

We studied quantitatively the effects of the discontinuity introduced in an otherwise homogeneous background by the cold walls of the standard spherical glass inserts commonly used in phantom measurements for calibration of threshold-based approaches to volumetric evaluation of PET investigations. We concentrated especially on the question of threshold-based volume determination. We computed analytically the convolution of an isotropic Gaussian point-spread function with the insert geometry (hot sphere + cold wall + warm background) and derived the theoretical background dependence of the volume reproducing threshold. This analysis shows a clear wall-related reduction of the optimal threshold with increasing background. The predictions of our theoretical analysis were verified in phantom measurements at background fractions between 0 and 0.29. Defining the background-corrected relative threshold [formula: see text] (T(abs): absolute volume reproducing threshold, A: measured activity at centre, B: background), we find that for a wall-less sphere T is independent of the background level. In the presence of cold walls, T drops (for not too small spheres, where recovery at the centre approaches 100%) from about 43% at B/A = 0 to about 25% at B/A = 0.5. Applying these thresholds to wall-less spheres leads to sizeable overestimates of the true volumes (43% at B/A = 0.5 for a sphere of 6 ml volume). We conclude that phantom measurements with standard sphere inserts for calibration of optimal thresholding algorithms introduce a systematic bias if performed at finite background levels. The observed background dependence is an artefact of the measurement procedure and does not reflect the conditions present in actual patient investigations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/55/4/013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 111

Metadata

Authors
Hofheinz, F., Dittrich, S., Pötzsch, C., & Hoff, J. V. D.
Venue
Physics in Medicine and Biology
Published
2010-01-28
Volume
55
Issue
4
Pages
1099-1113
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W1980291386
Cited by
111
References
0
FWCI
6.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of cold sphere walls in PET phantom measurements on the volume reproducing threshold. https://app.cochat.ai/papers/10.1088/0031-9155/55/4/013
The paper
Hofheinz, F., Dittrich, S., Pötzsch, C., & Hoff, J. V. D. (2010). Effects of cold sphere walls in PET phantom measurements on the volume reproducing threshold. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/55/4/013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.