Improved total variation-based CT image reconstruction applied to clinical data

Ritschl, Ludwig, Bergner, Frank, Fleischmann, Christof, Kachelrieß, Marc·2011·Physics in Medicine and Biology

Abstract

In computed tomography there are different situations where reconstruction has to be performed with limited raw data. In the past few years it has been shown that algorithms which are based on compressed sensing theory are able to handle incomplete datasets quite well. As a cost function these algorithms use the ℓ(1)-norm of the image after it has been transformed by a sparsifying transformation. This yields to an inequality-constrained convex optimization problem. Due to the large size of the optimization problem some heuristic optimization algorithms have been proposed in the past few years. The most popular way is optimizing the raw data and sparsity cost functions separately in an alternating manner. In this paper we will follow this strategy and present a new method to adapt these optimization steps. Compared to existing methods which perform similarly, the proposed method needs no a priori knowledge about the raw data consistency. It is ensured that the algorithm converges to the lowest possible value of the raw data cost function, while holding the sparsity constraint at a low value. This is achieved by transferring the step-size determination of both optimization procedures into the raw data domain, where they are adapted to each other. To evaluate the algorithm, we process measured clinical datasets. To cover a wide field of possible applications, we focus on the problems of angular undersampling, data lost due to metal implants, limited view angle tomography and interior tomography. In all cases the presented method reaches convergence within less than 25 iteration steps, while using a constant set of algorithm control parameters. The image artifacts caused by incomplete raw data are mostly removed without introducing new effects like staircasing. All scenarios are compared to an existing implementation of the ASD-POCS algorithm, which realizes the step-size adaption in a different way. Additional prior information as proposed by the PICCS algorithm can be incorporated easily into the optimization process.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/56/6/003

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Metadata

Authors
Ritschl, L., Bergner, F., Fleischmann, C., & Kachelrieß, M.
Venue
Physics in Medicine and Biology
Published
2011-02-16
Volume
56
Issue
6
Pages
1545-1561
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2071099763
Cited by
306
References
19
FWCI
31.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved total variation-based CT image reconstruction applied to clinical data. https://app.cochat.ai/papers/10.1088/0031-9155/56/6/003
The paper
Ritschl, L., Bergner, F., Fleischmann, C., & Kachelrieß, M. (2011). Improved total variation-based CT image reconstruction applied to clinical data. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/56/6/003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.