Improved total variation-based CT image reconstruction applied to clinical data
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
In computed tomography there are different situations where reconstruction has to be performed with limited raw data. In the past few years it has been shown that algorithms which are based on compressed sensing theory are able to handle incomplete datasets quite well. As a cost function these algorithms use the ℓ(1)-norm of the image after it has been transformed by a sparsifying transformation. This yields to an inequality-constrained convex optimization problem. Due to the large size of the optimization problem some heuristic optimization algorithms have been proposed in the past few years. The most popular way is optimizing the raw data and sparsity cost functions separately in an alternating manner. In this paper we will follow this strategy and present a new method to adapt these optimization steps. Compared to existing methods which perform similarly, the proposed method needs no a priori knowledge about the raw data consistency. It is ensured that the algorithm converges to the lowest possible value of the raw data cost function, while holding the sparsity constraint at a low value. This is achieved by transferring the step-size determination of both optimization procedures into the raw data domain, where they are adapted to each other. To evaluate the algorithm, we process measured clinical datasets. To cover a wide field of possible applications, we focus on the problems of angular undersampling, data lost due to metal implants, limited view angle tomography and interior tomography. In all cases the presented method reaches convergence within less than 25 iteration steps, while using a constant set of algorithm control parameters. The image artifacts caused by incomplete raw data are mostly removed without introducing new effects like staircasing. All scenarios are compared to an existing implementation of the ASD-POCS algorithm, which realizes the step-size adaption in a different way. Additional prior information as proposed by the PICCS algorithm can be incorporated easily into the optimization process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Andersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2006-00155 · Cited by 1,091
NESTA: A Fast and Accurate First-Order Method for Sparse Recovery
Becker, S., Bobin, J., & Candès, E. J. (2009) · Cited by 897
NESTA: A Fast and Accurate First-Order Method for Sparse Recovery
Becker, S., Bobin, J., & Candès, E. J. (2011) · SIAM Journal on Imaging Sciences · doi:10.1137/090756855 · Cited by 848
Reduction of CT artifacts caused by metallic implants.
Kalender, W. A., Hebel, R., & Ebersberger, J. (1987) · Radiology · doi:10.1148/radiology.164.2.3602406 · Cited by 751
Compressed sensing based interior tomography
Yu, H., & Wang, G. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/014 · Cited by 519
An Improved Algorithm for Reprojecting Rays through Pixel Images
Joseph, P. M. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307572 · Cited by 375
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
Bian, J., Siewerdsen, J. H., Han, X., Sidky, E. Y., Prince, J. L., Pelizzari, C. A., & Pan, X. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/001 · Cited by 373
Ohnesorge, B., Flohr, T., Schwarz, K., Heiken, J. P., & Bae, K. T. (2000) · Medical Physics · doi:10.1118/1.598855 · Cited by 248
Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro‐CT
Song, J., Liu, Q. H., Johnson, G. A., & Badea, C. T. (2007) · Medical Physics · doi:10.1118/1.2795830 · Cited by 183
Sidky, E. Y., Pan, X., Reiser, I. S., Nishikawa, R. M., Moore, R. H., & Kopans, D. B. (2009) · Medical Physics · doi:10.1118/1.3232211 · Cited by 181
Censor, Y., & Elfving, T. (2002) · SIAM Journal on Matrix Analysis and Applications · doi:10.1137/s089547980138705x · Cited by 162
Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography
Persson, M., Bone, D., & Elmqvist, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/318 · Cited by 161
Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware
Kachelrieß, M., Knaup, M., & Bockenbach, O. (2007) · Medical Physics · doi:10.1118/1.2710328 · Cited by 96
Self-citation
Cited by
Deep learning in optical metrology: a review
Zuo, C., Qian, J., Feng, S., Yin, W., Li, Y., Fan, P., Han, J., Qian, K., & Chen, Q. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00714-x · Cited by 711
Low-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Zhang, L., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Sidky, E. Y., Jørgensen, J. H., & Pan, X. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/10/3065 · Cited by 360
Compressed sensing electron tomography
Leary, R., Saghi, Z., Midgley, P. A., & Holland, D. J. (2013) · Ultramicroscopy · doi:10.1016/j.ultramic.2013.03.019 · Cited by 281
An Introduction to Sparse Stochastic Processes
Unser, M., & Tafti, P. D. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107415805 · Cited by 184
Metadata
- Authors
- Ritschl, L., Bergner, F., Fleischmann, C., & Kachelrieß, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-02-16
- Volume
- 56
- Issue
- 6
- Pages
- 1545-1561
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2071099763
- Cited by
- 306
- References
- 19
- FWCI
- 31.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.