The DOI matches its Crossref record.
Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility
Open accessAbstract
Reliable treatment planning of highly conformal scanned ion beam therapy demands accurate tools for the determination and characterization of the individual pencil-like beams building up the integral dose delivery and related mixed radiation field. At present, clinically practicable inverse treatment planning systems (TPSs) can only rely on fast-performing analytical algorithms. However, the rapidly emerging though more computationally intensive Monte Carlo (MC) methods can be employed to complement analytical TPS, e.g., via accurate calculations of the input beam-model data, together with a considerable reduction of the measuring time. Here we present the work done for the application of the FLUKA MC code to support several aspects of scanned ion beam delivery and treatment planning at the Heidelberg Ion Beam Therapy Center (HIT). Emphasis is given to the generation of the accelerator library and of experimentally validated TPS input basic data which are now in clinical use for proton and carbon ion therapy. Additionally, MC dose calculations of planned treatments in water are shown to represent a valuable tool for supporting treatment plan verification in comparison to dosimetric measurements. This paper can thus provide useful information and guidelines for the start-up and clinical operation of forthcoming ion beam therapy facilities similar to HIT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Development of the open-source dose calculation and optimization toolkit matRad
Wieser, H.-P., Cisternas, E., Wahl, N., Ulrich, S., Stadler, A., Mescher, H., Müller, L.-R., Klinge, T., Gabrys, H., Burigo, L., et al. (2017) · Medical Physics · doi:10.1002/mp.12251 · Cited by 325
Self-citationThe FLUKA Code: An Accurate Simulation Tool for Particle Therapy
Battistoni, G., Bauer, J., Boehlen, T. T., Cerutti, F., Chin, M. P. W., Dos Santos Augusto, R., Ferrari, A., Ortega, P. G., Kozłowska, W., Magro, G., et al. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00116 · Cited by 272
Self-citationCarante, M. P., Aricò, G., Ferrari, A., Kozlowska, W., Mairani, A., & Ballarini, F. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab490f · Cited by 23
Self-citation
Metadata
- Authors
- Parodi, K., Mairani, A., Brons, S., Hasch, B. G., Sommerer, F., Naumann, J., Jäkel, O., Haberer, T., & Debus, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-05-23
- Volume
- 57
- Issue
- 12
- Pages
- 3759-3784
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2077172984
- Cited by
- 221
- References
- 0
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility. https://app.cochat.ai/papers/10.1088/0031-9155/57/12/3759
- The paper
- Parodi, K., Mairani, A., Brons, S., Hasch, B. G., Sommerer, F., Naumann, J., Jäkel, O., Haberer, T., & Debus, J. (2012). Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/57/12/3759
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.