Range uncertainty in proton therapy due to variable biological effectiveness
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Traditionally, dose in proton radiotherapy is prescribed as Gy(RBE) by scaling up the physical dose by 10%. The relative biological effectiveness (RBE) of protons is considered to vary with dose-averaged linear energy transfer (LET(d)), dose (d) and (α/β)(x). The increase of RBE with depth causes a shift of the falloff of the beam, i.e. a change of the beam range. The magnitude of this shift will depend on dose and (α/β)(x). The aim of this project was to quantify the dependence of the range shift on these parameters. Three double-scattered beams of different ranges incident on a computational phantom consisting of different regions of interest (ROIs) were used. Each ROI was assigned with (α/β)(x) values between 0.5 and 20 Gy. The distribution of LET(d) within each ROI was obtained from a Monte Carlo simulation. The LET(d) distribution depends on the beam energy and thus its nominal range. The RBE values within the ROIs were calculated for doses between 1 and 15 Gy using an in-house developed biophysical model. Dose-volume histograms of the RBE-weighted doses were extracted for each ROI for a 'fixed RBE' (RBE = 1.1) and a 'variable RBE' (RBE = f (d, α/β, LET(d))), and the percentage difference in range was obtained from the difference of the percentage volumes at the distal 80% of the dose. Range differences in normal tissue ((α/β)(x) = 3 Gy) of the order of 3-2 mm were obtained, respectively, for a shallow (physical range 4.8 cm) and a deep (physical range 12.8 cm) beam, when a dose of 1 Gy normalized to the mid-SOBP was delivered. As the dose increased to 15 Gy, the variable RBE decreases below 1.1 which induces ranges of about 1 mm shorter than those obtained with an RBE of 1.1. The shift in the range of an SOBP when comparing biological dose distributions obtained with a fixed or a variable RBE was quantified as a function of dose, (α/β)(x) and physical range (as a surrogate of the initial beam energy). The shift increases with the physical range but decreases with increasing dose or (α/β)(x). The results of our study allow a quantitative consideration of RBE-caused range uncertainties as a function of treatment site and dose in treatment planning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364 · cited 3×
“In general, it is known that RBE increases with increasing LETd, whereas it decreases with increasing dose and (α/β)x (Paganetti et al 2002, Gerweck and Kozin 1999).”
BackgroundInfluentialSelf-citationRadiation Dose–Volume Effects of Optic Nerves and Chiasm
Mayo, C., Martel, M. K., Marks, L. B., Flickinger, J., Nam, J., & Kirkpatrick, J. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.07.1753 · Cited by 517
Clinical implementation of full Monte Carlo dose calculation in proton beam therapy
Paganetti, H., Jiang, H., Parodi, K., Slopsema, R. L., & Engelsman, M. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/023 · Cited by 305 · cited 1×
“However, figure 1(c) shows dose and LETd profiles produced with Monte Carlo calculations (Paganetti et al 2008) where five beams with the same range (51 mm) but different modulation widths (SOBP width from 10 to 50 mm) yield different values of LETd in the mid-SOBP position.”
BackgroundSelf-citationHawkins, R. B. (2003) · Radiation Research · doi:10.1667/rr3010 · Cited by 275
A Statistical Theory of Cell Killing by Radiation of Varying Linear Energy Transfer
Hawkins, R. B. (1994) · Radiation Research · doi:10.2307/3579114 · Cited by 235
Grassberger, C., Trofimov, A. V., Lomax, A., & Paganetti, H. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.10.027 · Cited by 226
Self-citationRelative biological effectiveness of proton beams in clinical therapy
Gerweck, L. E., & Kozin, S. V. (1999) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(98)00092-9 · Cited by 214
Elevated LET components in clinical proton beams
Grassberger, C., & Paganetti, H. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/20/011 · Cited by 184
Self-citationInactivation of V79 cells by low-energy protons, deuterons and helium-3 ions
FOLKARD, M. (1996) · International Journal of Radiation Biology · doi:10.1080/095530096145472 · Cited by 161 · cited 2×
“Experimental data show that proton RBE increases with increasing LETd (Folkard et al 1996, Belli et al 1989, 1993, Perris et al 1986, Coutrakon et al 1997, Wouters et al 1996, Schettino et al 2001).”
BackgroundBiological characteristics of carbon-ion therapy
Andō, K., & Kase, Y. (2009) · International Journal of Radiation Biology · doi:10.1080/09553000903072470 · Cited by 159 · cited 1×
“Ando and Kase (2009) have recently shown that in the case of carbon ions, this slope changes for different tissues, but the equivalent analysis does not exist for protons, so we are assuming a simple reciprocal dependence of RBEmax and RBEmin on (α/β)x.”
BackgroundLee, S. P., Leu, M. Y., Smathers, J. B., McBride, W. H., Parker, R. G., & Withers, H. R. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)00162-r · Cited by 128
Belli, M., Cera, F., Cherubini, R., Haque, A. M. I., Ianzini, F., Moschini, G., Sapora, O., Simone, G., Tabocchini, M. A., & Tiveron, P. (1993) · International Journal of Radiation Biology · doi:10.1080/09553009314550441 · Cited by 120 · cited 2×
“Experimental data show that proton RBE increases with increasing LETd (Folkard et al 1996, Belli et al 1989, 1993, Perris et al 1986, Coutrakon et al 1997, Wouters et al 1996, Schettino et al 2001).”
BackgroundWouters, B. G., Lam, G. K. Y., Oelfke, U., et al. (1996) · Radiation Research · doi:10.2307/3579588 · Cited by 120
Coutrakon, G. B., Cortese, J., Ghebremedhin, A., Hubbard, J., Johanning, J., Koss, P., Maudsley, G., Slater, C. R., ZUCCARELLI, C. N., & Robertson, J. (1997) · Medical Physics · doi:10.1118/1.598038 · Cited by 114 · cited 2×
“Experimental data show that proton RBE increases with increasing LETd (Folkard et al 1996, Belli et al 1989, 1993, Perris et al 1986, Coutrakon et al 1997, Wouters et al 1996, Schettino et al 2001).”
BackgroundSchettino, G., Folkard, M., Prise, K. M., Vojnovic, B., Bowey, A. G., & Michael, B. D. (2001) · Radiation Research · doi:10.1667/0033-7587(2001)156[0526:ldhich]2.0.co;2 · Cited by 87 · cited 2×
“Experimental data show that proton RBE increases with increasing LETd (Folkard et al 1996, Belli et al 1989, 1993, Perris et al 1986, Coutrakon et al 1997, Wouters et al 1996, Schettino et al 2001).”
BackgroundManagement of radon: a review of ICRP recommendations
Vaillant, L., & Bataillé, C. (2012) · Journal of Radiological Protection · doi:10.1088/0952-4746/32/3/r1 · Cited by 34
Paganetti, L. E. G. H. (2000) · International Journal of Radiation Biology · doi:10.1080/09553000050051007 · Cited by 30 · cited 1×
“Due to this increase, different authors have reported a shift of the biologically effective range of the beam by 1–2 mm (Robertson et al 1975, Paganetti et al 2000).”
Background
Cited by
Paganetti, H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r419 · Cited by 915
Self-citationMcNamara, A. L., Schuemann, J., & Paganetti, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/8399 · Cited by 345
Self-citationPaganetti, H., Blakely, E., Carabe‐Fernandez, A., Carlson, D. J., Das, I. J., Dong, L., Grosshans, D., Held, K. D., Mohan, R., Moiseenko, V., et al. (2019) · Medical Physics · doi:10.1002/mp.13390 · Cited by 310
Self-citationWedenberg, M., Lind, B. K., & Hårdemark, B. (2013) · Acta Oncologica · doi:10.3109/0284186x.2012.705892 · Cited by 269
Tommasino, F., & Durante, M. (2015) · Cancers · doi:10.3390/cancers7010353 · Cited by 252
“This aspect becomes even more relevant since delivery uncertainties are being reduced due to technical advances [55,95].”
BackgroundMethod
Metadata
- Authors
- Carabe, A., Moteabbed, M., Depauw, N., Schuemann, J., & Paganetti, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-02-14
- Volume
- 57
- Issue
- 5
- Pages
- 1159-1172
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2163678892
- Cited by
- 246
- References
- 17
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.