List-mode reconstruction for the Biograph mCT with physics modeling and event-by-event motion correction
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Whole-body PET/CT scanners are important clinical and research tools to study tracer distribution throughout the body. In whole-body studies, respiratory motion results in image artifacts. We have previously demonstrated for brain imaging that, when provided with accurate motion data, event-by-event correction has better accuracy than frame-based methods. Therefore, the goal of this work was to develop a list-mode reconstruction with novel physics modeling for the Siemens Biograph mCT with event-by-event motion correction, based on the MOLAR platform (Motion-compensation OSEM List-mode Algorithm for Resolution-Recovery Reconstruction). Application of MOLAR for the mCT required two algorithmic developments. First, in routine studies, the mCT collects list-mode data in 32 bit packets, where averaging of lines-of-response (LORs) by axial span and angular mashing reduced the number of LORs so that 32 bits are sufficient to address all sinogram bins. This degrades spatial resolution. In this work, we proposed a probabilistic LOR (pLOR) position technique that addresses axial and transaxial LOR grouping in 32 bit data. Second, two simplified approaches for 3D time-of-flight (TOF) scatter estimation were developed to accelerate the computationally intensive calculation without compromising accuracy. The proposed list-mode reconstruction algorithm was compared to the manufacturer's point spread function + TOF (PSF+TOF) algorithm. Phantom, animal, and human studies demonstrated that MOLAR with pLOR gives slightly faster contrast recovery than the PSF+TOF algorithm that uses the average 32 bit LOR sinogram positioning. Moving phantom and a whole-body human study suggested that event-by-event motion correction reduces image blurring caused by respiratory motion. We conclude that list-mode reconstruction with pLOR positioning provides a platform to generate high quality images for the mCT, and to recover fine structures in whole-body PET scans through event-by-event motion correction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
Self-citation
Cited by
Imaging synaptic density in the living human brain
Finnema, S. J., Nabulsi, N. B., Eid, T., Detyniecki, K., Lin, S.-F., Chen, M.-K., Dhaher, R., Matuskey, D., Baum, E., Holden, D., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6667 · Cited by 575
“Event-by-event motion correction (52) was included in the reconstruction on the basis of motion detection with a Polaris Vicra optical tracking system (NDI Systems) using reflectors mounted on a swim cap worn by the subject.”
MethodSelf-citationAssessment of a white matter reference region for 11 C-UCB-J PET quantification
Rossano, S., Toyonaga, T., Finnema, S. J., Naganawa, M., Lu, Y., Nabulsi, N., Ropchan, J., De Bruyn, S., Otoul, C., Stockis, A., et al. (2020) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x19879230 · Cited by 126
“Head motion detected by a Polaris Vicra optical tracking system was used for event-by-event motion correction during image reconstruction.(13) Dynamic images were reconstructed with 2 iterations of 30 subsets (2i, standard), as well as 3 and 4 iterations of 30 subsets (3i and 4i) to assess convergence of the white mat…”
MethodSelf-citationIn vivo evidence of lower synaptic vesicle density in schizophrenia
Radhakrishnan, R., Skosnik, P. D., Ranganathan, M., Naganawa, M., Toyonaga, T., Finnema, S., Hillmer, A. T., Esterlis, I., Huang, Y., Nabulsi, N., et al. (2021) · Molecular Psychiatry · doi:10.1038/s41380-021-01184-0 · Cited by 100
Self-citationLi, S., Naganawa, M., Pracitto, R., Najafzadeh, S., Holden, D., Henry, S., Matuskey, D., Emery, P. R., Cai, Z., Ropchan, J., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05149-3 · Cited by 61
“Event-by-event motion correction [28] was included in the reconstruction based on measurements with the Polaris Vicra sensor (NDI Systems, Waterloo, Canada) with reflectors mounted on a cap worn by the subject.”
MethodSelf-citation
Metadata
- Authors
- Jin, X., Chan, C., Mulnix, T., Panin, V., Casey, M. E., Liu, C., & Carson, R. E.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-07-29
- Volume
- 58
- Issue
- 16
- Pages
- 5567-5591
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2090952850
- Cited by
- 63
- References
- 1
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: List-mode reconstruction for the Biograph mCT with physics modeling and event-by-event motion correction. https://app.cochat.ai/papers/10.1088/0031-9155/58/16/5567
- The paper
- Jin, X., Chan, C., Mulnix, T., Panin, V., Casey, M. E., Liu, C., & Carson, R. E. (2013). List-mode reconstruction for the Biograph mCT with physics modeling and event-by-event motion correction. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/58/16/5567
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.