CoChat

Assessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

Purpose Synaptic abnormalities are associated with many brain disorders. Recently, we developed a novel synaptic vesicle glycoprotein 2A (SV2A) radiotracer [18 F]SynVesT-1 and demonstrated its excellent imaging and binding properties in nonhuman primates. The aim of this study was to perform dosimetry calculations in nonhuman primates and to evaluate this tracer in humans and assess its test-retest reliability in comparison with [11 C]UCB-J.Methods Three rhesus monkeys underwent whole body dynamic PET scanning to estimate the absorbed dose. PET scans in six healthy human subjects were acquired. Time-activity curves (TACs) were generated with defined regions of interest (ROI). Reproducibility of distribution volume (V T) values and its sensitivity to scan duration were assessed with the one-tissue compartment (1TC) model. Non-displaceable binding potential (BP ND) was calculated using centrum semiovale as the reference region.Results The dosimetry study showed high uptake in the urinary bladder and brain. In humans, [18 F]SynVesT-1 displayed high uptake with maximum SUV of ~10 and appropriate kinetics with a quick rise in tracer uptake followed by a gradual clearance. Mean 1TC V T values (mL/cm 3) ranged from 3.4 (centrum semiovale) to 19.6 (putamen) and were similar to those of [11 C]UCB-J. Regional BP ND values were 2.7-4.7 in gray matter areas, and mean BP ND values across all ROIs were ~ 21% higher than those of [11 C]UCB-J. The absolute test-retest variability of V T and BP ND was excellent (< 9%) across all brain regions.Conclusions [18 F]SynVesT-1 demonstrates outstanding characteristics in humans: fast and high brain uptake, appropriate tissue kinetics, high levels of specific binding, and excellent test-retest reproducibility of binding parameters. As such, [18 F]SynVesT-1 is proved to be a favorable radiotracer for SV2A imaging and quantification in humans.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00259-020-05149-3

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 35 references

Research works printed but not linked: 1

  1. Carson RE, Barker W, Liow J-S, Adler S, Johnson C. Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction of the HRRT. IEEE Nucl Sci Symp Conf Rec. 2003:M16–6.

Cited by

See all 62

Metadata

Authors
Li, S., Naganawa, M., Pracitto, R., Najafzadeh, S., Holden, D., Henry, S., Matuskey, D., Emery, P. R., Cai, Z., Ropchan, J., Nabulsi, N., Carson, R. E., & Huang, Y.
Affiliations
Yale University (US)
Corresponding author
  • Li, Songye
  • Huang, Yiyun
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2021-01-08
Volume
48
Issue
5
Pages
1327-1338
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W3118626742
Cited by
61
References
35
Citations by year
2026: 8 · 2025: 14 · 2024: 19 · 2023: 8 · 2022: 9 · 2021: 3
FWCI
5.15
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • European Journal of Nuclear Medicine and Molecular Imaging (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institute on Aging (R01AG052560, R01AG065474)
  • Michael J. Fox Foundation for Parkinson's Research
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neuropharmacology Research
Keywords
[18F]SynVesT-1, SV2A, test-retest reproducibility, dosimetry, non-human primates, rhesus monkeys, [11C]UCB-J, binding potential, volume of distribution, time-activity curves, one-tissue compartment model, brain uptake
MeSH terms
Animals, Brain, Fluorine Radioisotopes, Glycoproteins, Pyridines, Pyrrolidinones, Synaptic Vesicles, Reproducibility of Results, Radiopharmaceuticals, Positron-Emission Tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A. https://app.cochat.ai/papers/10.1007/s00259-020-05149-3
The paper
Li, S., Naganawa, M., Pracitto, R., Najafzadeh, S., Holden, D., Henry, S., Matuskey, D., Emery, P. R., Cai, Z., Ropchan, J., Nabulsi, N., Carson, R. E., & Huang, Y. (2021). Assessment of test-retest reproducibility of [18F]SynVesT-1, a novel radiotracer for PET imaging of synaptic vesicle glycoprotein 2A. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-020-05149-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.