Non-contact skin emissivity: measurement from reflectance using step change in ambient radiation temperature
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A method of estimating skin emissivity based on reflectance measurement upon transient stepwise change in the ambient radiation temperature was proposed. To effect this change, two shades at different temperatures were switched mechanically, and the change in radiation from the skin surface was recorded through an aperture for each shade by a high-resolution, fast-response radiometer having a sensitivity within the 8-14 microns range. Measurements were made on the forehead, forearm, palm and back of the hand in 10 male and 10 female subjects. No significant differences in emissivity were observed among sites and between sexes. The overall average of the skin emissivity obtained was 0.971 +/- 0.005 (SD). This result is inconsistent with most reported skin emissivity values. However, as the former studies had many inherent inadequacies, both theoretical and experimental, it is considered that most of these reported skin emissivities are unacceptable. The method proposed in this study has the following advantages: (1) relative calibration between instruments is unnecessary, (2) non-contact measurement can be achieved, and (3) each measurement can be made within one minute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hardy, J. D., & Muschenheim, C. (1934) · Journal of Clinical Investigation · doi:10.1172/jci100624 · Cited by 127
Cited by
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Reproducibility of infrared thermography measurements in healthy individuals
Zaproudina, N., Varmavuo, V., Airaksinen, O., & Närhi, M. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/4/007 · Cited by 246
“The results were corrected using a skin emissivity factor of 0.97 (Togawa 1989).”
MethodInfluentialInfrared thermal imaging for detection of peripheral vascular disorders
Philip, J., Bagavathiappan, S., Saravanan, T., Jayakumar, T., Raj, B., Karunanithi, R., Panicker, T. M. R., Korath, M., & Jagadeesan, K. (2009) · Journal of Medical Physics · doi:10.4103/0971-6203.48720 · Cited by 204
“21-23] Therefore, human beings can be treated as true black bodies.”
BackgroundRadiative and convective heat transfer coefficients of the human body in natural convection
Kurazumi, Y., Tsuchikawa, T., Ishii, J., Fukagawa, K., Yamato, Y., & Matsubara, N. (2008) · Building and Environment · doi:10.1016/j.buildenv.2007.12.012 · Cited by 158
“There have been many reports on the emissivity of the human body [49–76].”
Background
Metadata
- Authors
- Togawa, T.
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1989-02
- Volume
- 10
- Issue
- 1
- Pages
- 39-48
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2023522999
- Cited by
- 100
- References
- 1
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-contact skin emissivity: measurement from reflectance using step change in ambient radiation temperature. https://app.cochat.ai/papers/10.1088/0143-0815/10/1/004
- The paper
- Togawa, T. (1989). Non-contact skin emissivity: measurement from reflectance using step change in ambient radiation temperature. Clinical Physics and Physiological Measurement. https://doi.org/10.1088/0143-0815/10/1/004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.