Cited by 127Thermal Radiation and Cooling TechnologiesThermoregulation and physiological responsesInfrared Thermography in Medicine

the Radiation of Heat from the Human Body. Iv. the Emission, Reflection, and Transmission of Infra-Red Radiation By the Human Skin

Open access
Hardy, James D., Muschenheim, Carl·1934·Journal of Clinical Investigation

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci100624

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Commercially available PIR thermometers work with wavelengths from 8 μm to 14 μm.

    “Commercially available PIR thermometers work with wavelengths from 8 μm to 14 μm, thus the sensor must be adapted to the radiation wavelength of human body temperature [130,157].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [157]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 6

  1. Aldrich, L. B., Supplementary notes on body radiation. Smithsonian Misc. Collection, 1932, Vol. 85, No. 11.
  2. Cobet, R., and Bramigk, F., Uber Messung der Warmestrahlung der menschlichen Haut und ihr klinische Bedeutung. Deutsches Arch. f. klin. Med., 1924, 144, 45.
  3. Hardy, J. D., The radiation of heat from the human body. III. The human skin as a black-body radiator. J. Clin. Invest., 1934, 13, 615.
  4. Loewy, A., and Dorno, C., Uber Haut-und Korpertemperaturen und ihre Beeinflussung durch physikalische Reize. Strahlentherapie, 1925, 20, 411.
  5. Pauli, W. E., and Ivancevic, I., Untersuchungen uber das Absorptions- vermogen der Haut im langwelligen Gebiet des Spektrums. Strahlen- therapie, 1927, 25, 532.
  6. Gaertner, O., Die Durchlassigkeit der menschlichen Haut im Gebiete von 0.3-2.0 mu. Strahlentherapie, 1931, 40, 377.

Cited by

Sorted by citations

Authors
Hardy, J. D., & Muschenheim, C.
Venue
Journal of Clinical Investigation
Published
1934-09-01
Volume
13
Issue
5
Pages
817-831
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2166640371
Cited by
127
References
11
Citations by year
2026: 1 · 2025: 5 · 2024: 2 · 2023: 5 · 2022: 5 · 2021: 5 · 2020: 7 · 2019: 3 · 2017: 3 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 3 · 2012: 5
FWCI
41.37
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Investigation (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Thermal Radiation and Cooling Technologies
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
infrared radiation, human skin, thermal radiation, radiation emission, reflection, transmission, skin temperature, body heat loss

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review