The DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.
Reference values for resting blood flow to organs of man
Open accessAbstract
The lack of a reliable quantitative description of blood flow in man has hampered the development of accurate biokinetic models of essential elements, drugs, imaging agents, and carcinogens. In this paper we review and analyse data on blood flow and identify representative percentages of cardiac output and absolute blood flow rates to organs and tissues of man for use as reference values for biokinetic models. To keep the review and analysis to a manageable size we have limited attention to the resting state and have suggested reference values for absolute and relative flow rates only for adult males and females.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101994 · Cited by 2,059
Davies, D. F., & Shock, N. W. (1950) · Journal of Clinical Investigation · doi:10.1172/jci102286 · Cited by 1,133
Regional Blood Flow by Fractional Distribution of Indicators
Sapirstein, L. A. (1958) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1958.193.1.161 · Cited by 833
CAESAR, J., Shaldon, S., Chiandussi, L., Guevara, L., & Sherlock, S. (1961) · PubMed · Cited by 761
MEASUREMENT OF BLOOD-FLOW THROUGH SKELETAL MUSCLE BY INTRAMUSCULAR INJECTION OF XENON-133
Lassen, N. A., Lindbjerg, J., & Munck, O. (1964) · The Lancet · doi:10.1016/s0140-6736(64)91518-1 · Cited by 476
Skin blood flow and sweating changes following exercise training and heat acclimation
Roberts, M. F., Wenger, C. B., Stolwijk, J. A., & Nadel, E. R. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.43.1.133 · Cited by 438
Kety, S. S., & Schmidt, C. F. (1946) · Journal of Clinical Investigation · doi:10.1172/jci101680 · Cited by 433
ESTIMATION OF HEPATIC BLOOD FLOW WITH INDOCYANINE GREEN*
Leevy, C. M., Mendenhall, C. L., Lesko, W., & Howard, M. M. (1962) · Journal of Clinical Investigation · doi:10.1172/jci104570 · Cited by 380
Scheinberg, P., & Stead, E. A. (1949) · Journal of Clinical Investigation · doi:10.1172/jci102150 · Cited by 365
Blood Flow through Human Adipose Tissue Determined with Radioactive Xenon
Larsen, O. A., Lassen, N. A., & Quaade, F. (1966) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1966.tb03208.x · Cited by 337
Cited by
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Glial regulation of the cerebral microvasculature
Iadecola, C., & Nedergaard, M. (2007) · Nature Neuroscience · doi:10.1038/nn2003 · Cited by 1,153
Sex Differences in Pharmacokinetics and Pharmacodynamics
Soldin, O. P., & Mattison, D. R. (2009) · Clinical Pharmacokinetics · doi:10.2165/00003088-200948030-00001 · Cited by 1,163
Cardiac Output and Cerebral Blood Flow: The Integrated Regulation of Brain Perfusion in Adult Humans
Meng, L., Hou, W., Chui, J., Han, R., & Gelb, A. W. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000872 · Cited by 299
PBPK modelling of inter-individual variability in the pharmacokinetics of environmental chemicals
Bois, F. Y., Jamei, M., & Clewell, H. J. (2010) · Toxicology · doi:10.1016/j.tox.2010.06.007 · Cited by 194
Metadata
- Authors
- Williams, L. R., & Leggett, R. W.
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1989-08
- Volume
- 10
- Issue
- 3
- Pages
- 187-217
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2057904754
- Cited by
- 356
- References
- 116
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reference values for resting blood flow to organs of man. https://app.cochat.ai/papers/10.1088/0143-0815/10/3/001
- The paper
- Williams, L. R., & Leggett, R. W. (1989). Reference values for resting blood flow to organs of man. Clinical Physics and Physiological Measurement. https://doi.org/10.1088/0143-0815/10/3/001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.