CoChat

Determination of upper arm muscle and fat areas using electrical impedance measurements

Open access
Brown, B H, Karatzas, T, Nakielny, R, Clarke, R G · 1988 · Clinical Physics and Physiological Measurement
Cited by 72

The DOI matches its Crossref record.

Abstract

An electrical impedance technique is described which enables the cross-sectional areas of fat and muscle in the upper arm to be recorded. By making comparisons with measurements obtained using the x-ray technique of computerised tomography (CT) scanning it is shown that fat can be determined to a mean accuracy of 2.3 cm2 and muscle to a mean accuracy of 1.5 mm2. These results are more accurate than a parallel set of measurements made using the traditional anthropometric technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0143-0815/9/1/004

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Authors
Brown, B. H., Karatzas, T., Nakielny, R., & Clarke, R. G.
Venue
Clinical Physics and Physiological Measurement
Published
1988-02
Volume
9
Issue
1
Pages
47-55
ISSN
0143-0815 (ISSN-L)
OpenAlex
W1967182437
Cited by
72
References
0
FWCI
0.28
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of upper arm muscle and fat areas using electrical impedance measurements. https://app.cochat.ai/papers/10.1088/0143-0815/9/1/004
The paper
Brown, B. H., Karatzas, T., Nakielny, R., & Clarke, R. G. (1988). Determination of upper arm muscle and fat areas using electrical impedance measurements. Clinical Physics and Physiological Measurement. https://doi.org/10.1088/0143-0815/9/1/004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.