The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Electrical impedance tomography (EIT): a review
Abstract
Electrical impedance tomography (EIT) has been the subject of quite intensive research for about 20 years but has yet to become established as a routine tool in healthcare. None the less the volume of published research work in this area is still rising. This review takes a broad look at what has been achieved and attempts to give the reader sufficient information to form an opinion as to the likely future for this interesting area of research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,186
Frerichs, I. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/201 · Cited by 348
Relation between tissue structure and imposed electrical current flow in cervical neoplasia
Brown, B. H., Tidy, J. A., Boston, K., Blackett, A. D., Smallwood, R. H., & Sharp, F. (2000) · The Lancet · doi:10.1016/s0140-6736(99)09095-9 · Cited by 205
Self-citationImaging with electricity: Report of the European Concerted Action on Impedance Tomography
Boone, K., Barber, D., & Brown, B. (1997) · Journal of Medical Engineering & Technology · doi:10.3109/03091909709070013 · Cited by 192
Self-citationA Review of Parameters for the Bioelectrical Characterization of Breast Tissue
JOSSINET, J., & Schmitt, M. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb09446.x · Cited by 156
Cardiac and respiratory related electrical impedance changes in the human thorax
Brown, B. H., Barber, D. C., Morice, A. H., & Leathard, A. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.310088 · Cited by 125
Self-citationMulti-frequency imaging and modelling of respiratory related electrical impedance changes
Brown, B. H., Barber, D. C., Wang, W., Lu, L., Leathard, A. D., Smallwood, R. H., Hampshire, A., Mackay, R., & Hatzigalanis, K. (1994) · Physiological Measurement · doi:10.1088/0967-3334/15/2a/001 · Cited by 104
Self-citationAvill, R., Mangnall, Y., Bird, N. C., Brown, B. H., arber, D. C., Seagar, A., Johnson, A. G., & Read, N. W. (1987) · Gastroenterology · doi:10.1016/0016-5085(87)90978-4 · Cited by 102
Self-citation
Cited by
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
Electrical impedance myography: Background, current state, and future directions
Rutkove, S. B. (2009) · Muscle & Nerve · doi:10.1002/mus.21362 · Cited by 292
Metadata
- Authors
- Brown, B.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2003-01
- Volume
- 27
- Issue
- 3
- Pages
- 97-108
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2055571910
- Cited by
- 556
- References
- 15
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical impedance tomography (EIT): a review. https://app.cochat.ai/papers/10.1080/0309190021000059687
- The paper
- Brown, B. (2003). Electrical impedance tomography (EIT): a review. Journal of Medical Engineering & Technology. https://doi.org/10.1080/0309190021000059687
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.