The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
A scaled gradient projection method for constrained image deblurring
Open accessAbstract
A class of scaled gradient projection methods for optimization problems with simple constraints is considered. These iterative algorithms can be useful in variational approaches to image deblurring that lead to minimized convex nonlinear functions subject to non-negativity constraints and, in some cases, to an additional flux conservation constraint. A special gradient projection method is introduced that exploits effective scaling strategies and steplength updating rules, appropriately designed for improving the convergence rate. We give convergence results for this scheme and we evaluate its effectiveness by means of an extensive computational study on the minimization problems arising from the maximum likelihood approach to image deblurring. Comparisons with the standard expectation maximization algorithm and with other iterative regularization schemes are also reported to show the computational gain provided by the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
Bertsekas, D. P. (1997) · Journal of the Operational Research Society · doi:10.1038/sj.jors.2600425 · Cited by 11,726
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866 · cited 1×
“First, the special structure of the constraints makes the projection of a vector on the feasible region a non-excessively expensive operation: this is obviously the case of the problem (2), but also of the problem (3), in which the projection can be performed by linear-time algorithms [3–7].”
BackgroundFigueiredo, M. A. T., Nowak, R. D., & Wright, S. J. (2007) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2007.910281 · Cited by 3,524
Two-Point Step Size Gradient Methods
BARZILAI, J., & BORWEIN, J. M. (1988) · IMA Journal of Numerical Analysis · doi:10.1093/imanum/8.1.141 · Cited by 2,873
Computational Methods for Inverse Problems
Vogel, C. R. (2002) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898717570 · Cited by 2,370
Iterative Methods for Optimization
Kelley, C. T. (1999) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611970920 · Cited by 2,052
Introduction to Inverse Problems in Imaging
Bertero, M., & Boccacci, P. (1998) · Institute of Physics eBooks · doi:10.1887/0750304359 · Cited by 1,899
Metadata
- Authors
- Bonettini, S., Zanella, R., & Zanni, L.
- Venue
- Inverse Problems
- Publisher
- IOP Publishing
- Published
- 2008-11-13
- Volume
- 25
- Issue
- 1
- Pages
- 015002
- ISSN
- 0266-5611 (ISSN-L)
- 1361-6420
- OpenAlex
- W2015131139
- Cited by
- 254
- References
- 34
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A scaled gradient projection method for constrained image deblurring. https://app.cochat.ai/papers/10.1088/0266-5611/25/1/015002
- The paper
- Bonettini, S., Zanella, R., & Zanni, L. (2009). A scaled gradient projection method for constrained image deblurring. Inverse Problems. https://doi.org/10.1088/0266-5611/25/1/015002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.