The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM)
Open accessAbstract
We propose a compressive sensing approach for multi-energy computed tomography (CT), namely the prior rank, intensity and sparsity model (PRISM). To further compress the multi-energy image for allowing the reconstruction with fewer CT data and less radiation dose, the PRISM models a multi-energy image as the superposition of a low-rank matrix and a sparse matrix (with row dimension in space and column dimension in energy), where the low-rank matrix corresponds to the stationary background over energy that has a low matrix rank, and the sparse matrix represents the rest of distinct spectral features that are often sparse. Distinct from previous methods, the PRISM utilizes the generalized rank, e.g., the matrix rank of tight-frame transform of a multi-energy image, which offers a way to characterize the multi-level and multi-filtered image coherence across the energy spectrum. Besides, the energy-dependent intensity information can be incorporated into the PRISM in terms of the spectral curves for base materials, with which the restoration of the multi-energy image becomes the reconstruction of the energy-independent material composition matrix. In other words, the PRISM utilizes prior knowledge on the generalized rank and sparsity of a multi-energy image, and intensity/spectral characteristics of base materials. Furthermore, we develop an accurate and fast split Bregman method for the PRISM and demonstrate the superior performance of the PRISM relative to several competing methods in simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Self-citationCandes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Robust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 6,921
A Singular Value Thresholding Algorithm for Matrix Completion
Cai, J.-F., Candès, E. J., & Shen, Z. (2010) · SIAM Journal on Optimization · doi:10.1137/080738970 · Cited by 5,809
Exact Matrix Completion via Convex Optimization
Candès, E. J., & Recht, B. (2009) · Foundations of Computational Mathematics · doi:10.1007/s10208-009-9045-5 · Cited by 4,877
The Split Bregman Method for L1-Regularized Problems
Goldstein, T., & Osher, S. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080725891 · Cited by 4,282
Self-citation
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
LEARN: Learned Experts’ Assessment-Based Reconstruction Network for Sparse-Data CT
Chen, H., Zhang, Y., Chen, Y., Zhang, J., Zhang, W., Sun, H., Lv, Y., Liao, P., Zhou, J., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2805692 · Cited by 433
Self-citationBadea, C. T., Clark, D. P., Holbrook, M., Srivastava, M., Mowery, Y., & Ghaghada, K. B. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab03e2 · Cited by 74
Metadata
- Authors
- Gao, H., Yu, H., Osher, S., & Wang, G.
- Venue
- Inverse Problems
- Publisher
- IOP Publishing
- Published
- 2011-10-25
- Volume
- 27
- Issue
- 11
- Pages
- 115012
- ISSN
- 0266-5611 (ISSN-L)
- 1361-6420
- OpenAlex
- W1982059935
- Cited by
- 264
- References
- 34
- FWCI
- 10.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM). https://app.cochat.ai/papers/10.1088/0266-5611/27/11/115012
- The paper
- Gao, H., Yu, H., Osher, S., & Wang, G. (2011). Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM). Inverse Problems. https://doi.org/10.1088/0266-5611/27/11/115012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.