The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
Open accessAbstract
In x-ray computed tomography (CT), materials having different elemental compositions can be represented by identical pixel values on a CT image (ie, CT numbers), depending on the mass density of the material. Thus, the differentiation and classification of different tissue types and contrast agents can be extremely challenging. In dual-energy CT, an additional attenuation measurement is obtained with a second x-ray spectrum (ie, a second "energy"), allowing the differentiation of multiple materials. Alternatively, this allows quantification of the mass density of two or three materials in a mixture with known elemental composition. Recent advances in the use of energy-resolving, photon-counting detectors for CT imaging suggest the ability to acquire data in multiple energy bins, which is expected to further improve the signal-to-noise ratio for material-specific imaging. In this review, the underlying motivation and physical principles of dual- or multi-energy CT are reviewed and each of the current technical approaches is described. In addition, current and evolving clinical applications are introduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationChen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Self-citationVision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 948
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
Dual-Energy CT: General Principles
Johnson, T. R. C. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9116 · Cited by 631
Dual-Energy CT–Based Monochromatic Imaging
Yu, L., Leng, S., & McCollough, C. H. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9121 · Cited by 609
Self-citationK-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
Roessl, E., & Proksa, R. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/020 · Cited by 558
Cited by
Dual-Energy CT: New Horizon in Medical Imaging
Goo, H. W., & Goo, J. M. (2017) · Korean Journal of Radiology · doi:10.3348/kjr.2017.18.4.555 · Cited by 408
Detector-based spectral CT with a novel dual-layer technology: principles and applications
Rassouli, N., Etesami, M., Dhanantwari, A., & Rajiah, P. (2017) · Insights into Imaging · doi:10.1007/s13244-017-0571-4 · Cited by 300
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
Dual-energy CT of acute bowel ischemia
Obmann, M. M., Punjabi, G., Obmann, V. C., Boll, D. T., Heye, T., Benz, M. R., & Yeh, B. M. (2022) · Abdominal Radiology · doi:10.1007/s00261-021-03188-4 · Cited by 50
DXA-equivalent quantification of bone mineral density using dual-layer spectral CT scout scans
Laugerette, A., Schwaiger, B. J., Brown, K., Frerking, L. C., Kopp, F. K., Mei, K., Sellerer, T., Kirschke, J., Baum, T., Gersing, A. S., et al. (2019) · European Radiology · doi:10.1007/s00330-019-6005-6 · Cited by 29
Metadata
- Authors
- McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G.
- Venue
- Radiology
- Published
- 2015-09
- Volume
- 276
- Issue
- 3
- Pages
- 637-653
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1926920987
- Cited by
- 1,598
- References
- 33
- FWCI
- 43.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. https://app.cochat.ai/papers/10.1148/radiol.2015142631
- The paper
- McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015). Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. Radiology. https://doi.org/10.1148/radiol.2015142631
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.