Abstract
We developed computational methods and tools to assess organ doses for pediatric and adult patients undergoing computed tomography (CT) examinations. We used the International Commission on Radiological Protection (ICRP) reference pediatric and adult phantoms combined with the Monte Carlo simulation of a reference CT scanner to establish comprehensive organ dose coefficients (DC), organ absorbed dose per unit volumetric CT Dose Index (CTDIvol) (mGy/mGy). We also developed methods to estimate organ doses with tube current modulation techniques and size specific dose estimates. A graphical user interface was designed to obtain user input of patient- and scan-specific parameters, and to calculate and display organ doses. A batch calculation routine was also integrated into the program to automatically calculate organ doses for a large number of patients. We entitled the computer program, National Cancer Institute dosimetry system for CT(NCICT). We compared our dose coefficients with those from CT-Expo, and evaluated the performance of our program using CT patient data. Our pediatric DCs show good agreements of organ dose estimation with those from CT-Expo except for thyroid. Our results support that the adult phantom in CT-Expo seems to represent a pediatric individual between 10 and 15 years rather than an adult. The comparison of CTDIvol values between NCICT and dose pages from 10 selected CT scans shows good agreements less than 12% except for two cases (up to 20%). The organ dose comparison between mean and modulated mAs shows that mean mAs-based calculation significantly overestimates dose (up to 2.4-fold) to the organs in close proximity to lungs in chest and chest-abdomen-pelvis scans. Our program provides more realistic anatomy based on the ICRP reference phantoms, higher age resolution, the most up-to-date bone marrow dosimetry, and several convenient features compared to previous tools. The NCICT will be available for research purpose in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The 2007 recommendations of the International Commission on Radiological Protection
Valentin, J. (2007) · Elsevier eBooks · Cited by 4,105
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection
Vetter, R. J. (2008) · Health Physics · doi:10.1097/01.hp.0000324200.73903.5b · Cited by 1,263
Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2
(2006) · National Academies Press eBooks · doi:10.17226/11340 · Cited by 904
Smith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898
Self-citationSpecific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Basic anatomical and physiological data for use in radiological protection : reference values
Valentin, J. (2002) · Medical Entomology and Zoology · Cited by 680
Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations
Boone, J., Strauss, K., Cody, D., McCollough, C., McNitt-Gray, M., Toth, T., Goske, M., & Frush, D. (2011) · doi:10.37206/143 · Cited by 551 · cited 1×
“…regression equations for 16 cm and 32 cm diameter CTDI phantoms from the relationship between effective diameter (cm) and conversion factors reported by AAPM TG 204 [27]: where y is the weighting factors to calculate SSDE from CTDI vol and x is the effective diameter 8 (cm) measured from patients.”
MethodRealistic reference phantoms: An ICRP/ICRU joint effort
(2009) · Annals of the ICRP · doi:10.1016/j.icrp.2009.09.001 · Cited by 496
CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT
Stamm, G., & Nagel, H. D. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-35937 · Cited by 353
Cited by
Radiation exposure from pediatric CT scans and subsequent cancer risk in The Netherlands
Meulepas, J. M., Ronckers, C. M., Smets, A. M. J. B., Nievelstein, R. A. J., Gradowska, P., Lee, C., Jahnen, A., van Straten, M., de Wit, M.-C. Y., Zonnenberg, B., et al. (2019) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djy104 · Cited by 360
Bosch de Basea, M., Thierry-Chef, I., Harbron, R., Hauptmann, M., Byrnes, G., Bernier, M.-O., Le Cornet, L., Dabin, J., Ferro, G., Istad, T. S., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02620-0 · Cited by 349
“Doses were estimated using the National Cancer Institute Dosimetry System for CT 42 .”
Self-citationHauptmann, M., Byrnes, G., Cardis, E., Bernier, M.-O., Blettner, M., Dabin, J., Engels, H., Istad, T. S., Johansen, C., Kaijser, M., et al. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(22)00655-6 · Cited by 273
Self-citationBrady, S. L., Trout, A. T., Somasundaram, E., Anton, C. G., Li, Y., & Dillman, J. R. (2021) · Radiology · doi:10.1148/radiol.2020202317 · Cited by 189
Childhood cancer risks estimates following CT scans: an update of the French CT cohort study
Foucault, A., Ancelet, S., Dreuil, S., Caër-Lorho, S., Ducou Le Pointe, H., Brisse, H., Chateil, J.-F., Lee, C., Leuraud, K., & Bernier, M.-O. (2022) · European Radiology · doi:10.1007/s00330-022-08602-z · Cited by 39
Self-citationDose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT)
Thierry-Chef, I., Ferro, G., Le Cornet, L., Dabin, J., Istad, T. S., Jahnen, A., Lee, C., Maccia, C., Malchair, F., Olerud, H. M., et al. (2021) · Radiation Research · doi:10.1667/rade-20-00231.1 · Cited by 31
“The use of these anatomically realistic phantom models gives NCICT an advantage over other lookup table-based dose calculators such as CT Expo (44) and ImPACT (45), which use simpler, mathematical phantoms based on the Oak Ridge National Laboratory (ORNL, Oak Ridge, TN) model (46).”
MethodInfluentialSelf-citation
Metadata
- Authors
- Lee, C., Kim, K. P., Bolch, W. E., Moroz, B. E., & Folio, L.
- Venue
- Journal of Radiological Protection
- Publisher
- IOP Publishing
- Published
- 2015-11-26
- Volume
- 35
- Issue
- 4
- Pages
- 891-909
- ISSN
- 0952-4746 (ISSN-L)
- 1361-6498
- OpenAlex
- W2419362857
- Cited by
- 197
- References
- 35
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.