Dose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT)
Open accessAbstract
Within the European Epidemiological Study to Quantify Risks for Paediatric Computerized Tomography (EPI-CT study), a cohort was assembled comprising nearly one million children, adolescents and young adults who received over 1.4 million computed tomography (CT) examinations before 22 years of age in nine European countries from the late 1970s to 2014. Here we describe the methods used for, and the results of, organ dose estimations from CT scanning for the EPI-CT cohort members. Data on CT machine settings were obtained from national surveys, questionnaire data, and the Digital Imaging and Communications in Medicine (DICOM) headers of 437,249 individual CT scans. Exposure characteristics were reconstructed for patients within specific age groups who received scans of the same body region, based on categories of machines with common technology used over the time period in each of the 276 participating hospitals. A carefully designed method for assessing uncertainty combined with the National Cancer Institute Dosimetry System for CT (NCICT, a CT organ dose calculator), was employed to estimate absorbed dose to individual organs for each CT scan received. The two-dimensional Monte Carlo sampling method, which maintains a separation of shared and unshared error, allowed us to characterize uncertainty both on individual doses as well as for the entire cohort dose distribution. Provided here are summaries of estimated doses from CT imaging per scan and per examination, as well as the overall distribution of estimated doses in the cohort. Doses are provided for five selected tissues (active bone marrow, brain, eye lens, thyroid and female breasts), by body region (i.e., head, chest, abdomen/pelvis), patient age, and time period (1977-1990, 1991-2000, 2001-2014). Relatively high doses were received by the brain from head CTs in the early 1990s, with individual mean doses (mean of 200 simulated values) of up to 66 mGy per scan. Optimization strategies implemented since the late 1990s have resulted in an overall decrease in doses over time, especially at young ages. In chest CTs, active bone marrow doses dropped from over 15 mGy prior to 1991 to approximately 5 mGy per scan after 2001. Our findings illustrate patterns of age-specific doses and their temporal changes, and provide suitable dose estimates for radiation-induced risk estimation in epidemiological studies.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Uncertainties in individual doses are not negligible (geometric s.d. of the order of 2 on average), particularly in early years, and could not be fully integrated in the risk analyses.
“While the EPI-CT dose reconstruction is based on sophisticated modeling of doses and associated shared and unshared uncertainties, uncertainties in individual doses are not negligible (geometric s.d. of the order of 2 on average7), particularly in early years, and could not be fully integrated in the risk analyses.”
From Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults (2023) · cites this paper as [7]
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,738 · see citing works
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735 · see citing works
Self-citationEstimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · see citing works
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029 · see citing works
Self-citationProjected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
de González, A. B. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,880 · see citing works
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,751 · see citing works
Miglioretti, D. L., Johnson, E., Williams, A. E., Greenlee, R. T., Weinmann, S. A., Solberg, L. I., Feigelson, H. S., Roblin, D. W., Flynn, M. J., Vanneman, N., et al. (2013) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476 · see citing works
Health Risks from Exposure to Low Levels of Ionizing Radiation
National Research Council (2006) · National Academies Press eBooks · doi:10.17226/11340 · Cited by 909 · see citing works
CT Dose Reduction and Dose Management Tools: Overview of Available Options
McCollough, C. H., Bruesewitz, M. R., & Kofler, J. M. (2006) · Radiographics · doi:10.1148/rg.262055138 · Cited by 769 · see citing works
Silva, A. C., Lawder, H. J., Hara, A. K., Kujak, J. L., & Pavlicek, W. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2953 · Cited by 561 · see citing works
Realistic reference phantoms: An ICRP/ICRU joint effort
Menzel, H.-G., Clement, C. H., & DeLuca, P. M. (2009) · Annals of the ICRP · doi:10.1016/j.icrp.2009.09.001 · Cited by 496 · see citing works
Solid cancer incidence among the Life-span study of atomic-bomb survivors: 1958-2009
Grant, E. J., Brenner, A., Sugiyama, H., Sakata, R., Sadakane, A., Utada, M., Cahoon, E. K., Milder, C. M., Soda, M., Cullings, H. M., et al. (2017) · Radiation Research · doi:10.1667/rr14492.1 · Cited by 434 · see citing works
Paterson, A., Frush, D. P., & Donnelly, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760297 · Cited by 422 · see citing works
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 388 · see citing works
Radiation Cataractogenesis: A Review of Recent Studies
Ainsbury, E. A., Bouffler, S. D., Dörr, W., Graw, J., Muirhead, C. R., Edwards, A. A., & Cooper, J. S. (2009) · Radiation Research · doi:10.1667/rr1688.1 · Cited by 375 · see citing works
Radiation exposure from pediatric CT scans and subsequent cancer risk in The Netherlands
Meulepas, J. M., Ronckers, C. M., Smets, A. M. J. B., Nievelstein, R. A. J., Gradowska, P., Lee, C., Jahnen, A., van Straten, M., de Wit, M.-C. Y., Zonnenberg, B., et al. (2019) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djy104 · Cited by 360 · see citing works
Self-citationCT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT
Stamm, G., & Nagel, H. D. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-35937 · Cited by 353 · see citing works
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345 · see citing works
The UF family of reference hybrid phantoms for computational radiation dosimetry
Lee, C., Lodwick, D. L., Hurtado, J., Pafundi, D., Williams, J. L., & Bolch, W. E. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/002 · Cited by 345 · see citing works
Self-citationDose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
Gies, M., Kalender, W. A., Wolf, H., Suess, C., & Madsen, M. T. (1999) · Medical Physics · doi:10.1118/1.598779 · Cited by 306 · see citing works
Contents, preface, executive summary, chapters 1 and 2
Valentin, J. (2005) · Annals of the ICRP · doi:10.1016/j.icrp.2005.11.002 · Cited by 270 · see citing works
CT Radiation Dose Optimization and Estimation: an Update for Radiologists
Goo, H. W. (2012) · Korean Journal of Radiology · doi:10.3348/kjr.2012.13.1.1 · Cited by 254 · see citing works
de Gonzalez, A. B., Salotti, J. A., McHugh, K., Little, M. P., Harbron, R. W., Lee, C., Ntowe, E., Braganza, M. Z., Parker, L., Rajaraman, P., et al. (2016) · British Journal of Cancer · doi:10.1038/bjc.2015.415 · Cited by 244 · see citing works
Self-citationHuang, W.-Y., Muo, C.-H., Lin, C.-Y., Jen, Y.-M., Yang, M.-H., Lin, J.-C., Sung, F.-C., & Kao, C.-H. (2014) · British Journal of Cancer · doi:10.1038/bjc.2014.103 · Cited by 213 · see citing works
Journy, N., Rehel, J.-L., Ducou Le Pointe, H., Lee, C., Brisse, H., Chateil, J.-F., Caer-Lorho, S., Laurier, D., & Bernier, M.-O. (2015) · British Journal of Cancer · doi:10.1038/bjc.2014.526 · Cited by 202 · see citing works
Self-citationLee, C., Kim, K. P., Bolch, W. E., Moroz, B. E., & Folio, L. R. (2015) · Journal of Radiological Protection · doi:10.1088/0952-4746/35/4/891 · Cited by 197 · see citing works
Self-citationKrille, L., Dreger, S., Schindel, R., Albrecht, T., Asmussen, M., Barkhausen, J., Berthold, J. D., Chavan, A., Claussen, C., Forsting, M., et al. (2015) · Radiation and Environmental Biophysics · doi:10.1007/s00411-014-0580-3 · Cited by 184 · see citing works
Self-citationMathematical Phantoms Representing Children of Various Ages for Use in Estimates of Internal Dose
USDOE, Cristy, M., & USNRC (1980) · doi:10.2172/5308345 · Cited by 168 · see citing works
Turner, A. C., Zhang, D., Khatonabadi, M., Zankl, M., DeMarco, J. J., Cagnon, C. H., CODY, D. D., Stevens, D. M., McCollough, C. H., & McNitt‐Gray, M. F. (2011) · Medical Physics · doi:10.1118/1.3533897 · Cited by 149 · see citing works
Krille, L., Dreger, S., Schindel, R., Albrecht, T., Asmussen, M., Barkhausen, J., Berthold, J. D., Chavan, A., Claussen, C. D., Forsting, M., et al. (2017) · Radiation and Environmental Biophysics · doi:10.1007/s00411-017-0694-5 · Cited by 130 · see citing works
Self-citationICRP Publication 143: Paediatric Reference Computational Phantoms
Bolch, W. E., Eckerman, K. F., Endo, A., Hunt, J. G., Jokisch, D. W., Kim, C. H., Kim, K.-P., Lee, C., Li, J., Petoussi-Henss, N., et al. (2020) · Annals of the ICRP · doi:10.1177/0146645320915031 · Cited by 123 · see citing works
Self-citationLee, C., Kim, K. P., Long, D., & Bolch, W. E. (2012) · Medical Physics · doi:10.1118/1.3693052 · Cited by 116 · see citing works
Self-citationAutomatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography
Papadakis, A. E., & Damilakis, J. E. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000537 · Cited by 84 · see citing works
Emerging Techniques for Dose Optimization in Abdominal CT
Kaza, R. K., Platt, J. F., Goodsitt, M. M., Al-Hawary, M. M., Maturen, K. E., Wasnik, A. P., & Pandya, A. (2014) · Radiographics · doi:10.1148/rg.341135038 · Cited by 83 · see citing works
Bernier, M., Baysson, H., Pearce, M. S., Moissonnier, M., Cardis, E., Hauptmann, M., Struelens, L., Dabin, J., Johansen, C., Journy, N., et al. (2018) · International Journal of Epidemiology · doi:10.1093/ije/dyy231 · Cited by 70 · see citing works
Self-citationKim, K. P., de González, A. B., Pearce, M. S., Salotti, J. A., Parker, L., McHugh, K., Craft, A. W., & Lee, C. R. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr429 · Cited by 66 · see citing works
Self-citationLand, C. E., Kwon, D., Hoffman, F. O., Moroz, B. E., Drozdovitch, V., Bouville, A. C., Beck, H. L., Luckyanov, N., Weinstock, R. M., & Simon, S. L. (2015) · Radiation Research · doi:10.1667/rr13794.1 · Cited by 65 · see citing works
Self-citationSimon, S. L., Hoffman, F. O., & Hofer, Ė. (2014) · Radiation Research · doi:10.1667/rr13729.1 · Cited by 63 · see citing works
Self-citationWe can do better than effective dose for estimating or comparing low-dose radiation risks
Brenner, D. J. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.07.001 · Cited by 59 · see citing works
Journy, N., Lee, C., Harbron, R. W., McHugh, K., Pearce, M. S., & de González, A. B. (2016) · British Journal of Cancer · doi:10.1038/bjc.2016.351 · Cited by 58 · see citing works
Self-citationde Basea, M. B., Pearce, M. S., Kesminiene, A., Bernier, M., Dabin, J., Engels, H., Hauptmann, M., Krille, L., Meulepas, J. M., Struelens, L., et al. (2015) · Journal of Radiological Protection · doi:10.1088/0952-4746/35/3/611 · Cited by 56 · see citing works
Self-citationBeyond the bombs: cancer risks of low-dose medical radiation
Einstein, A. J. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60897-6 · Cited by 56 · see citing works
Li, X., Segars, W. P., & Samei, E. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/16/4525 · Cited by 44 · see citing works
Akiba, S., & Mizuno, S. (2012) · Journal of Radiological Protection · doi:10.1088/0952-4746/32/1/73 · Cited by 43 · see citing works
Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models
Tian, X., Li, X., Segars, W. P., Frush, D. P., Paulson, E. K., & Samei, E. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/24/8755 · Cited by 40 · see citing works
Thierry-Chef, I., Dabin, J., Friberg, E. G., Hermen, J., Istad, T. S., Jahnen, A., Krille, L., Lee, C., Maccia, C., Nordenskjöld, A., et al. (2013) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph10020717 · Cited by 38 · see citing works
Self-citationReduction in radiation doses from paediatric CT scans in Great Britain
Lee, C., Pearce, M. S., Salotti, J. A., Harbron, R. W., Little, M. P., McHugh, K., Chapple, C.-L., & de González, A. B. (2016) · British Journal of Radiology · doi:10.1259/bjr.20150305 · Cited by 36 · see citing works
Self-citationAnalysis of Factors Influencing Patient Doses from CT in Norway
Olerud, H. M. (1997) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032039 · Cited by 34 · see citing works
Self-citationMcMillan, K. L., Bostani, M., Cagnon, C. H., Yu, L., Leng, S., McCollough, C. H., & McNitt‐Gray, M. F. (2017) · Medical Physics · doi:10.1002/mp.12314 · Cited by 33 · see citing works
Subtle excess in lifetime cancer risk related to CT scanning in Spanish young people
de Basea, M. B., Moriña, D., Figuerola, J., Barber, I., Muchart, J., Lee, C., & Cardis, E. (2018) · Environment International · doi:10.1016/j.envint.2018.07.020 · Cited by 31 · see citing works
Self-citationIn x‐ray computed tomography, technique factors should be selected appropriate to patient size
Huda, W., Bushong, S. C., & Hendee, W. R. (2001) · Medical Physics · doi:10.1118/1.1388903 · Cited by 30 · see citing works
Giacomuzzi, S. M., Torbica, P., Rieger, M., Lottersberger, C., Peer, S., Peer, R., Perkmann, R., Buchberger, W., Bale, R. J., Mallouhi, A., et al. (2001) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2001-15831 · Cited by 29 · see citing works
Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation
Schlattl, H., Zankl, M., Becker, J., & Hoeschen, C. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/20/6309 · Cited by 27 · see citing works
Radiation dose to the lens from CT of the head in young people
Harbron, R. W., Ainsbury, E. A., Barnard, S. G. R., Lee, C. R., McHugh, K., de González, A. B., Edyvean, S., & Pearce, M. S. (2019) · Clinical Radiology · doi:10.1016/j.crad.2019.06.029 · Cited by 27 · see citing works
Self-citationAutomatic computed tomography patient dose calculation using DICOM header metadata
Jahnen, A., Kohler, S., Hermen, J., Tack, D., & Back, C. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr338 · Cited by 26 · see citing works
Self-citationDabin, J., Mencarelli, A., McMillan, D., Romanyukha, A. A., Struelens, L., & Lee, C. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/11/4168 · Cited by 25 · see citing works
Self-citationJacob, P., Meckbach, R., Kaiser, J. C., & Эдуардович, С. М. (2010) · Mutation research. Fundamental and molecular mechanisms of mutagenesis · doi:10.1016/j.mrfmmm.2010.01.005 · Cited by 23 · see citing works
de González, A. B., Journy, N., Lee, C., Morton, L. M., Harbron, R. W., Stewart, D. R., Parker, L., Craft, A. W., McHugh, K., Little, M. P., et al. (2017) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-16-1011 · Cited by 23 · see citing works
Self-citationJourny, N., Dreuil, S., Boddaert, N., Chateil, J., Defez, D., Pointe, H. D. L., Garcier, J., Guersen, J., Geryes, B. H., Jahnen, A., et al. (2017) · European Radiology · doi:10.1007/s00330-017-5001-y · Cited by 23 · see citing works
Self-citationPractical advices for optimal CT scanner dose in children
Malchair, F., & Maccia, C. (2020) · Radioprotection · doi:10.1051/radiopro/2020046 · Cited by 22 · see citing works
Self-citationComputed Tomography in Germany
Pokora, R. M., Krille, L., Dreger, S., Lee, C., Günster, C., Zeeb, H., & Blettner, M. (2016) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2016.0721 · Cited by 21 · see citing works
Self-citationLee, C., Flynn, M. J., Judy, P. F., CODY, D. D., Bolch, W. E., & Kruger, R. L. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.16.16979 · Cited by 21 · see citing works
Self-citationLai, C. W. K., Cheung, H.-Y., Chan, T.-P., & Wong, T. H. (2015) · Radioprotection · doi:10.1051/radiopro/2015003 · Cited by 17 · see citing works
Kauffman, J. D., Litz, C. N., Thiel, S. A., Nguyen, A. T. H., Carey, A., Danielson, P. D., & Chandler, N. M. (2018) · Journal of Surgical Research · doi:10.1016/j.jss.2018.06.005 · Cited by 16 · see citing works
Lee, C., Journy, N., Moroz, B. E., Little, M. P., Harbron, R. W., McHugh, K., Pearce, M. S., & de González, A. B. (2018) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncy184 · Cited by 14 · see citing works
Self-citationZacharia, T. T., Kanekar, S. G., Nguyen, D. T. D., & Moser, K. W. (2010) · Emergency Radiology · doi:10.1007/s10140-010-0908-5 · Cited by 13 · see citing works
Walsh, L., & Nekolla, E. A. (2015) · Journal of Radiological Protection · doi:10.1088/0952-4746/35/3/e9 · Cited by 9 · see citing works
Olerud, H. M., Toft, B., Flatabø, S., Jahnen, A., Lee, C., & Thierry-Chef, I. (2016) · European Radiology · doi:10.1007/s00330-015-4157-6 · Cited by 5 · see citing works
Self-citationValentin, J. (2005) · Annals of the ICRP · doi:10.1016/j.icrp.2005.10.001 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Bosch de Basea, M., Thierry-Chef, I., Harbron, R., Hauptmann, M., Byrnes, G., Bernier, M.-O., Le Cornet, L., Dabin, J., Ferro, G., Istad, T. S., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02620-0 · Cited by 349 · see citing works
“Detailed methods have been published 7,26,40 .”
Self-citationHauptmann, M., Byrnes, G., Cardis, E., Bernier, M.-O., Blettner, M., Dabin, J., Engels, H., Istad, T. S., Johansen, C., Kaijser, M., et al. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(22)00655-6 · Cited by 273 · see citing works
Self-citationRühm, W., Laurier, D., & Wakeford, R. (2021) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2021.503436 · Cited by 94 · see citing works
Radiation-Related Thyroid Cancer
Saenko, V., & Mitsutake, N. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnad022 · Cited by 64 · see citing works
A Historical Survey of Key Epidemiological Studies of Ionizing Radiation Exposure
Little, M. P., Bаzyка, D., de González, A. B., Brenner, A. V., Chumak, V. V., Cullings, H. M., Daniels, R. D., French, B. C., Grant, E. J., Hamada, N., et al. (2024) · Radiation Research · doi:10.1667/rade-24-00021.1 · Cited by 23 · see citing works
Self-citationEvaluation of paediatric computed tomography imaging for brain, and abdomen procedures
Almujally, A., Tamam, N. M., Sulieman, A., Tài, D. T., Omer, H. B., Abuhadi, N. H., Salah, H., Mattar, E. H., Khandaker, M. U., & Bradley, D. A. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110271 · Cited by 20 · see citing works
Pasqual, E., Castaño‐Vinyals, G., Thierry-Chef, I., Kojimahara, N., Sim, M. R., Kundi, M., Krewski, D. R., Momoli, F., Lacour, B., Rémen, T., et al. (2020) · Neuroepidemiology · doi:10.1159/000506131 · Cited by 11 · see citing works
Self-citationSaint‐Hubert, M. D., Boissonnat, G., Schneider, U., Bäumer, C., Verbeek, N. G., Esser, J., Wulff, J., Stuckmann, F., Suesselbeck, F., Nabha, R., et al. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1222800 · Cited by 10 · see citing works
Self-citationMahendra, M., Chu, P., Amin, E. K., Nawaytou, H. M., Duncan, J. R., Fineman, J. R., & Smith‐Bindman, R. (2023) · Pulmonary Circulation · doi:10.1002/pul2.12282 · Cited by 9 · see citing works
Radiation Dose to Pediatric Patients From Radiopharmaceuticals
Treves, S. T., & Fahey, F. H. (2021) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2021.11.007 · Cited by 9 · see citing works
Thierry-Chef, I., Timmermann, B., Journy, N., Bernier, M., McNally, R., Dabin, J., Brualla, L., Haghdoost, S., Sarukhan, A., Haustermans, K. M., et al. (2023) · EPJ Nuclear Sciences & Technologies · doi:10.1051/epjn/2023009 · Cited by 8 · see citing works
Self-citationKwon, D., Simon, S. L., Hoffman, F. O., & Pfeiffer, R. M. (2023) · PLoS ONE · doi:10.1371/journal.pone.0290498 · Cited by 7 · see citing works
Self-citationA systematic review of radiation dose to the eye lens from pediatric brain computed tomography scans
Perdomo, A. A., Forster, J. C., & Badawy, M. K. (2025) · Pediatric Radiology · doi:10.1007/s00247-025-06371-7 · Cited by 6 · see citing works
Patient-specific organ dose calculation using automatic segmentation and extension of CT scans
Morató, S., Juste, B., Miró, R., Santos, A., Badal, A., Lee, C., Verdú, G., & Mille, M. M. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.113013 · Cited by 5 · see citing works
Self-citationRepresentative Organ Doses from Computed Tomography (CT) Exams from a Large International Registry
Chu, P., Stewart, C., Kofler, C., Mahendra, M., Wang, Y., Chu, C. A., Lee, C., Bolch, W. E., & Smith‐Bindman, R. (2024) · Radiation Research · doi:10.1667/rade-24-00178.1 · Cited by 4 · see citing works
Self-citationBadawy, M. K., Kashish, K., Payne, S., & Masterson, M. (2024) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-024-01383-3 · Cited by 3 · see citing works
Visweswaran, S., Raavi, V., Basheerudeen, S. A. S., Kanagaraj, K., Prasad, A., Gnanasekaran, T. S., Pattan, S., Shanmugam, P., Ozhimuthu, A., Joseph, S., et al. (2021) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2021.503404 · Cited by 3 · see citing works
Quantifying and Contextualizing Radiation Doses in Common Pediatric Medical Imaging Examinations
Stewart, C., Alber, S. A., Mahendra, M., Kofler, C., Tran, T. N., Domal, S. J., Bowles, E. J. A., Weinmann, S. A., Greenlee, R. T., Stout, N. K., et al. (2025) · The Journal of Pediatrics Clinical Practice · doi:10.1016/j.jpedcp.2025.200166 · Cited by 5 · see citing works
Zeeb, H., Merzenich, H., Blettner, M., & Wollschläger, D. (2023) · Springer eBooks · doi:10.1007/978-1-4614-6625-3_68-1 · Cited by 3 · see citing works
Un enjeu majeur de radioprotection en imagerie médicale
Bertho, J., & Bourguignon, M. (2024) · Radioprotection · doi:10.1051/radiopro/2024003 · Cited by 3 · see citing works
Lee, C., Moroz, B. E., Thome, C., Gaudreau, K., Emami, P., & Little, M. P. (2024) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad315 · Cited by 2 · see citing works
Self-citationThe international society for radiation epidemiology and dosimetry (ISoRED)
Harbron, R. W., de González, A. B., Griffin, K., Al‐Nabulsi, I., Thierry-Chef, I., Wilson, L. J., & Cardis, E. (2024) · Journal of Radiological Protection · doi:10.1088/1361-6498/ad746e · Cited by 1 · see citing works
Self-citationInnovative Protocol Optimization for Radiation Dose Reduction in Pediatric Head CT Scan
Caduri, S., Lakovsky, Y., Dar, G., Golan, A., Benyamin, D., Vider, K., Berger‐Achituv, S., & Konen, O. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.112931 · Cited by 1 · see citing works
CT scans in young people and risk of hematological malignancies
(2023) · Nature Medicine · doi:10.1038/s41591-023-02671-3
Effective Doses of Children During X-Ray Diagnostic Examinations: A Literary Review
Shatskiy, I. G., Druzhinina, P. S., Kapyrina, Y. N., & Осипов, М. В. (2023) · Medical Radiology and radiation safety · doi:10.33266/1024-6177-2023-68-6-27-41
Ito, T. (2025) · Journal of Radiation Protection and Research · doi:10.14407/jrpr.2024.00143
Akla, A. T., Hamidi, A. S., Hassan, A. M., & Nehme, Y. B. (2025) · Bright Sky Publications eBooks · doi:10.62906/bs.book.340
Reconstruction of the radiological component of the exposome in the CONSTANCES cohort
Sauce, J., Renaud, P., Chaikh, A., Métivier, J.-M., Ribet, C., Michel, C., Mandin, C., Henyoh, A. M. S., Cœuret-Pellicer, M., Saey, L., et al. (2026) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2026.181855
Self-citationGotanda, T., Akagawa, T., Hasuo, T., Nishihara, S., Matsuura, K., Kawaji, Y., Yatake, H., Imai, S., Gotanda, R., & Katsuda, T. (2026) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncag046
Garg, A., Ahmad, M., & Shah, M. A. (2026) · Radiation effects and defects in solids · doi:10.1080/10420150.2026.2718062
- Authors
- Thierry-Chef, I., Ferro, G., Le Cornet, L., Dabin, J., Istad, T. S., Jahnen, A., Lee, C., Maccia, C., Malchair, F., Olerud, H. M., Harbron, R. W., Figuerola, J., Hermen, J., Moissonnier, M., Bernier, M.-O., de Basea, M. B., Byrnes, G., Cardis, E., Hauptmann, M., Journy, N., Kesminiene, A., Meulepas, J. M., Pokora, R., & Simon, S. L.
- Affiliations
- Universitat Pompeu Fabra (ES)
- Centre international de recherche sur le cancer (FR)
- Institute of Medical Biostatistics, Epidemiology and Informatics, University Medical Center Mainz, Mainz, Germany
- Belgian Nuclear Research Centre (BE)
- Norwegian Radiation and Nuclear Safety Authority (NO)
- Luxembourg Institute of Science and Technology, Esch-sur-Alzette, Luxembourg
- Division of Cancer Epidemiology and Genetics (US)
- CAATS, Sèvres, France
- University of South-Eastern Norway (NO)
- Luxembourg Institute of Science and Technology (LU)
- Institut de Radioprotection et de Sûreté Nucléaire (FR)
- Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain
- The Netherlands Cancer Institute (NL)
- University Medical Center of the Johannes Gutenberg University Mainz (DE)
- Corresponding author
- Thierry-Chef, Isabelle
- ORCID
- Venue
- Radiation Research
- Publisher
- Radiation Research Society
- Published
- 2021-04-28
- Volume
- 196
- Issue
- 1
- Pages
- 74-99
- ISSN
- 0033-7587 (ISSN-L)
- 1938-5404
- OpenAlex
- W3157149673
- Cited by
- 31
- References
- 69
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 6 · 2023: 10 · 2022: 2 · 2021: 3 · 2020: 1
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Radiation Research (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- Newcastle University ePrints (Newcastle Univesity)
- Funders
- World Health Organization
- National Institute for Health Research Health Protection Research Unit
- Cancer Research UK (C22891/A16015)
- National Institute for Health and Care Research (RRX119)
- Newcastle University
- Public Health England
- Helse Nord-Trøndelag
- Universitätsmedizin der Johannes Gutenberg-Universität Mainz
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Digital Radiography and Breast Imaging
- Keywords
- pediatric computed tomography, organ dose estimation, DICOM header, Monte Carlo uncertainty analysis, head CT, chest CT, brain dose, lens dose, thyroid dose, breast dose, radiation-induced cancer risk, children and adolescents
- MeSH terms
- Adolescent, Child, Child, Preschool, Europe, Female, Humans, Infant, Infant, Newborn, Male, Radiation Dosage, Tomography, X-Ray Computed, Cohort Studies, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review