The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Magnetoresistive sensors
Open accessAbstract
Magnetoresistive sensors using spin valves and magnetic tunnel junctions are reviewed, considering applications as readers in hard disk drives, as well as applications where the ultimate field detection limits are required (from nT down to pT). The sensor noise level in quasi-DC or high-frequency applications is described, leading to sensor design considerations concerning biomedical and read head applications. Magnetic tunnel junction based sensors using MgO barriers appear as the best candidates for ultra-low field (pT) detection, either in the high-frequency regime, or for quasi-DC applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giant Magnetoresistance of (001)Fe/(001)Cr Magnetic Superlattices
Baibich, M. N., Broto, J. M., Fert, A., Van Dau, F. N., Petroff, F., Etienne, P., Creuzet, G., Friederich, A., & Chazelas, J. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.2472 · Cited by 9,415
Tunneling between ferromagnetic films
Julliere, M. (1975) · Physics Letters A · doi:10.1016/0375-9601(75)90174-7 · Cited by 4,003
Giant room-temperature magnetoresistance in single-crystal Fe/MgO/Fe magnetic tunnel junctions
Yuasa, S., Nagahama, T., Fukushima, A., Suzuki, Y., & Ando, K. (2004) · Nature Materials · doi:10.1038/nmat1257 · Cited by 3,331
Giant tunnelling magnetoresistance at room temperature with MgO (100) tunnel barriers
Parkin, S. S. P., Kaiser, C., Panchula, A., Rice, P. M., Hughes, B., Samant, M., & Yang, S.-H. (2004) · Nature Materials · doi:10.1038/nmat1256 · Cited by 3,320
Thermal Agitation of Electric Charge in Conductors
Nyquist, H. (1928) · Physical Review · doi:10.1103/physrev.32.110 · Cited by 3,115
Giant magnetoresistive in soft ferromagnetic multilayers
Dieny, B., Speriosu, V. S., Parkin, S. S. P., Gurney, B. A., Wilhoit, D. R., & Mauri, D. (1991) · Physical Review B · doi:10.1103/physrevb.43.1297 · Cited by 1,885
1fnoise and other slow, nonexponential kinetics in condensed matter
Weissman, M. B. (1988) · Reviews of Modern Physics · doi:10.1103/revmodphys.60.537 · Cited by 1,370
1/ƒ noise is no surface effect
Hooge, F. N. (1969) · Physics Letters A · doi:10.1016/0375-9601(69)90076-0 · Cited by 1,094
Über spontane Stromschwankungen in verschiedenen Elektrizitätsleitern
Schottky, W. (1918) · Annalen der Physik · doi:10.1002/andp.19183622304 · Cited by 911
A biosensor based on magnetoresistance technology
Baselt, D. R., Lee, G. U., Natesan, M., Metzger, S. W., Sheehan, P. E., & Colton, R. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00037-2 · Cited by 823
Cited by
Sensors and biosensors based on magnetic nanoparticles
Rocha-Santos, T. A. P. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.016 · Cited by 547
Advances in Magnetic Field Sensors
Ripka, P., & Janosek, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2043429 · Cited by 546
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
Self-citationOptimal magnetic sensor vests for cardiac source imaging
Lau, S., Petković, B., & Haueisen, J. (2016) · Sensors · doi:10.3390/s16060754 · Cited by 17
Metadata
- Authors
- Freitas, P. P., Ferreira, R., Cardoso, S., & Cardoso, F.
- Venue
- Journal of Physics: Condensed Matter
- Publisher
- IOP Publishing
- Published
- 2007-04-05
- Volume
- 19
- Issue
- 16
- Pages
- 165221
- ISSN
- 0953-8984 (ISSN-L)
- 1361-648X
- OpenAlex
- W4249123797
- Cited by
- 422
- References
- 22
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetoresistive sensors. https://app.cochat.ai/papers/10.1088/0953-8984/19/16/165221
- The paper
- Freitas, P. P., Ferreira, R., Cardoso, S., & Cardoso, F. (2007). Magnetoresistive sensors. Journal of Physics: Condensed Matter. https://doi.org/10.1088/0953-8984/19/16/165221
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.