Transmission and emission x-ray microscopy: operation modes, contrast mechanisms and applications
Open accessThe DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Abstract
Advances in microscopy techniques based on x-rays have opened unprecedented opportunities in terms of spatial resolution, combined with chemical and morphology sensitivity, to analyze solid, soft and liquid matter. The advent of ultrabright third and fourth generation photon sources and the continuous development of x-ray optics and detectors has pushed the limits of imaging and spectroscopic analysis to structures as small as a few tens of nanometers. Specific interactions of x-rays with matter provide elemental and chemical sensitivity that have made x-ray spectromicroscopy techniques a very attractive tool, complementary to other microscopies, for characterization in all actual research fields. The x-ray penetration power meets the demand to examine samples too thick for electron microscopes implementing 3D imaging and recently also 4D imaging which adds time resolution as well. Implementation of a variety of phase contrast techniques enhances the structural sensitivity, especially for the hard x-ray regime. Implementation of lensless or diffraction imaging helps to enhance the lateral resolution of x-ray imaging to the wavelength dependent diffraction limit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596 · cited 1×
“In recent years, Fienup’s hybrid input–output algorithm (Fienup 1982) has inspired the development of other iterative methods, such as the difference map algorithm (Elser 2003a, 2003b), the shrink-wrap method (Marchesini et al 2003), and the relaxed averaged alternating reflections algorithm (Luke…”
MethodGABOR, D. (1948) · Nature · doi:10.1038/161777a0 · Cited by 4,548 · cited 2×
“Diffraction imaging also relates to Gabor’s early work on holography (Gabor 1948), as it requires highly coherent sources.”
BackgroundMethodA practical algorithm for the determination of phase from image and diffraction plane pictures
Gerchberg, R. W. (1972) · Optik · Cited by 4,519
Stöhr, J. (1992) · Springer Series in Surface Sciences · doi:10.1007/978-3-662-02853-7 · Cited by 2,307
Elements of Modern X‐ray Physics
Als‐Nielsen, J., & McMorrow, D. (2011) · Wiley eBooks · doi:10.1002/9781119998365 · Cited by 2,204
Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object
Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R., & Wilkins, S. W. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01010.x · Cited by 2,062 · cited 1×
“…as in-line holography (Pagot et al 2003), holotomography (Cloetens et al 1999), iterative schemes (Allen et al 2001), wavefield propagation (Teague 1983, Paganin et al 2002), phase contrast projection microscopy (Mayo et al 2003b), or synchrotron-based non-interferometric techniques (Gureyev 1999).”
MethodPotential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022 · cited 1×
“This ‘diffract-and-destroy’ approach could have especially farreaching repercussions for specimens available in multiple identical copies, such as macromolecules and viruses, since it may permit 3D structure determination without resorting to crystallization (Neutze et al 2000).”
BackgroundMiao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976 · cited 1×
“The first complete demonstration of x-ray diffraction microscopy, the ‘ABC’ of diffraction microscopy, came about a decade later (Miao et al 1999).”
Background
Cited by
X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
Nanoscale Hard X-Ray Microscopy Methods for Materials Studies
Holt, M., Harder, R., Winarski, R., & Rose, V. (2013) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-071312-121654 · Cited by 183
Pascolo, L., Gianoncelli, A., Kaulich, B., Rizzardi, C., Schneider, M., Bottin, C., Polentarutti, M., Kiskinova, M., Longoni, A., & Melato, M. (2011) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-8-7 · Cited by 47
Self-citation
Metadata
- Authors
- Kaulich, B., Thibault, P., Gianoncelli, A., & Kiskinova, M.
- Venue
- Journal of Physics: Condensed Matter
- Publisher
- IOP Publishing
- Published
- 2011-02-04
- Volume
- 23
- Issue
- 8
- Pages
- 083002
- ISSN
- 0953-8984 (ISSN-L)
- 1361-648X
- OpenAlex
- W2140216106
- Cited by
- 169
- References
- 103
- FWCI
- 18.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.