Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Synchrotron soft X-ray imaging and fluorescence microscopy reveal novel features of asbestos body morphology and composition in human lung tissues

Open access

Abstract

BACKGROUND: Occupational or environmental exposure to asbestos fibres is associated with pleural and parenchymal lung diseases. A histopathologic hallmark of exposure to asbestos is the presence in lung parenchyma of the so-called asbestos bodies. They are the final product of biomineralization processes resulting in deposition of endogenous iron and organic matter (mainly proteins) around the inhaled asbestos fibres. For shedding light on the formation mechanisms of asbestos bodies it is of fundamental importance to characterize at the same length scales not only their structural morphology and chemical composition but also to correlate them to the possible alterations in the local composition of the surrounding tissues. Here we report the first correlative morphological and chemical characterization of untreated paraffinated histological lung tissue samples with asbestos bodies by means of soft X-ray imaging and X-Ray Fluorescence (XRF) microscopy, which reveals new features in the elemental lateral distribution. RESULTS: The X-ray absorption and phase contrast images and the simultaneously monitored XRF maps of tissue samples have revealed the location, distribution and elemental composition of asbestos bodies and associated nanometric structures. The observed specific morphology and differences in the local Si, Fe, O and Mg content provide distinct fingerprints characteristic for the core asbestos fibre and the ferruginous body. The highest Si content is found in the asbestos fibre, while the shell and ferruginous bodies are characterized by strongly increased content of Mg, Fe and O compared to the adjacent tissue. The XRF and SEM-EDX analyses of the extracted asbestos bodies confirmed an enhanced Mg deposition in the organic asbestos coating. CONCLUSIONS: The present report demonstrates the potential of the advanced synchrotron-based X-ray imaging and microspectroscopy techniques for studying the response of the lung tissue to the presence of asbestos fibres. The new results obtained by simultaneous structural and chemical analysis of tissue specimen have provided clear evidence that Mg, in addition to Fe, is also involved in the formation mechanisms of asbestos bodies. This is the first important step to further thorough investigations that will shed light on the physiopathological role of Mg in tissue response to the asbestos toxicity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1743-8977-8-7

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 SEM-EDX analyses of an extracted asbestos body. Panel A: SEM image of an asbestos body placed on a glass support. In panel B higher magnification of the denudated part of the asbestos body, indicated by arrow in panel A. Panels C and D: EDX spectra acquired on the selected regions, indicated in panel B as points C and D respectively. The Cr signal originates from the glass support and should be ignored. Electron microprobe size of 100 nm2 (see material and methods for instrument details).
Figure 1 SEM-EDX analyses of an extracted asbestos body. Panel A: SEM image of an asbestos body placed on a glass support. In panel B higher magnification of the denudated part of the asbestos body, indicated by arrow in panel A. Panels C and D: EDX spectra acquired on the selected regions, indicated in panel B as points C and D respectively. The Cr signal originates from the glass support and should be ignored. Electron microprobe size of 100 nm2 (see material and methods for instrument details).CC BY · PubMed Central
Figure 2 Soft X-ray microscopy and XRF analyses on an extracted asbestos body. The images show the analyses of an extracted asbestos body deposited on a Si3N4 window. Panel A: X-ray absorption image acquired at 1.935 keV (40× 48 μm2 area, 20 ms dwell time, 500 nm spot size). Panel SEM: SEM image of the same asbestos body. Panels Mg, Si, Fe, N, O and C: XRF maps acquired at 1.935 keV with 6 s/pixel dwell time (Si and Mg) and at 0.9 keV (Fe, N and O) with 4 s/pixel dwell time, both with 500 nm spot size. Panel D and E: XRF spectra collected on the points indicated in panel A at 2 keV and 1.4 keV respectively (30 s acquisition time).
Figure 2 Soft X-ray microscopy and XRF analyses on an extracted asbestos body. The images show the analyses of an extracted asbestos body deposited on a Si3N4 window. Panel A: X-ray absorption image acquired at 1.935 keV (40× 48 μm2 area, 20 ms dwell time, 500 nm spot size). Panel SEM: SEM image of the same asbestos body. Panels Mg, Si, Fe, N, O and C: XRF maps acquired at 1.935 keV with 6 s/pixel dwell time (Si and Mg) and at 0.9 keV (Fe, N and O) with 4 s/pixel dwell time, both with 500 nm spot size. Panel D and E: XRF spectra collected on the points indicated in panel A at 2 keV and 1.4 keV respectively (30 s acquisition time).CC BY · PubMed Central
Figure 3 Soft X-ray microscopy and XRF analyses of an asbestos body in human lung tissue. Panel A: visible light image of the tissue with the asbestos body. Panels B and C: absorption and phase contrast images respectively acquired at a photon energy of 2018 eV (25 × 40 μm2 size, 30 ms dwell time, 415 nm spot size). Panels Fe, Si and Mg: elemental distribution (25 × 35 μm2 size, 30 s/pixel dwell time, 1 μm spot size) among the area of panels B and C, acquired at 2 keV, (Si and Mg), and at 1,3 keV (Fe). Panel D and E: XRF spectra collected in the points a and b (see panel B) at 1.3 keV (D) and at 2 keV (E) with 180 s acquisition time).
Figure 3 Soft X-ray microscopy and XRF analyses of an asbestos body in human lung tissue. Panel A: visible light image of the tissue with the asbestos body. Panels B and C: absorption and phase contrast images respectively acquired at a photon energy of 2018 eV (25 × 40 μm2 size, 30 ms dwell time, 415 nm spot size). Panels Fe, Si and Mg: elemental distribution (25 × 35 μm2 size, 30 s/pixel dwell time, 1 μm spot size) among the area of panels B and C, acquired at 2 keV, (Si and Mg), and at 1,3 keV (Fe). Panel D and E: XRF spectra collected in the points a and b (see panel B) at 1.3 keV (D) and at 2 keV (E) with 180 s acquisition time).CC BY · PubMed Central
Figure 4 Soft X-ray microscopy and XRF analyses of asbestos and ferruginous bodies in human lung tissue. Panel A: visible light image of the analysed asbestos body. Panel B and C: phase contrast (B) and absorption (C) images respectively acquired at photon energy of 1.3 keV (50 × 50 μm2 size, 10 ms dwell time, 250 nm spot size). Other panels (50 × 50 μm2, 7 s/pixel dwell time, 500 nm spot size): XRF maps acquired on the region showed in panel C, at 1.3 keV (Fe and O) and at 1.93 keV (Mg and Si). Panel Si-Fe: colocalization of Si (in green) and Fe (in red). Panel Fe-O: colocalization of Fe (in green) and O (in red). Panel D and E: XRF spectra acquired in points a, b and c (see panel B) at 1.3 keV (D) and 2 keV (E) with 175 s acquisition time.
Figure 4 Soft X-ray microscopy and XRF analyses of asbestos and ferruginous bodies in human lung tissue. Panel A: visible light image of the analysed asbestos body. Panel B and C: phase contrast (B) and absorption (C) images respectively acquired at photon energy of 1.3 keV (50 × 50 μm2 size, 10 ms dwell time, 250 nm spot size). Other panels (50 × 50 μm2, 7 s/pixel dwell time, 500 nm spot size): XRF maps acquired on the region showed in panel C, at 1.3 keV (Fe and O) and at 1.93 keV (Mg and Si). Panel Si-Fe: colocalization of Si (in green) and Fe (in red). Panel Fe-O: colocalization of Fe (in green) and O (in red). Panel D and E: XRF spectra acquired in points a, b and c (see panel B) at 1.3 keV (D) and 2 keV (E) with 175 s acquisition time.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Research works printed but not linked: 2

  1. Ide-Ektessabi A Applications of Synchrotron Radiation: Microbeams in Cell Micro Biology and Medicine 2007 Springer Verlag Berlin Heidelberg
  2. Kaulich B Susini J David C Di Fabrizio E Morrison G Charalambous P Aoki S, Kagoshima Y, Suzuki Y A European Twin X-ray Microscopy Station Commissioned at ELETTRA Proceeding of 8th International Conference on X-ray micros, Conf Proc Series IPAP 2006 7 22 25

Cited by

See all 47

Metadata

Authors
Pascolo, L., Gianoncelli, A., Kaulich, B., Rizzardi, C., Schneider, M., Bottin, C., Polentarutti, M., Kiskinova, M., Longoni, A., & Melato, M.
Affiliations
  • AREA Science Park (IT)
  • University of Trieste (IT)
  • Ospedale di Monfalcone (IT)
  • Politecnico di Milano (IT)
Corresponding author
Pascolo, Lorella
Venue
Particle and Fibre Toxicology
Published
2011
Volume
8
Issue
1
Pages
7
ISSN
1743-8977 (ISSN-L)
OpenAlex
W2123590398
Cited by
47
References
46
Citations by year
2026: 1 · 2025: 3 · 2024: 1 · 2023: 4 · 2022: 5 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 6 · 2017: 6 · 2016: 4 · 2015: 4 · 2014: 3 · 2013: 4 · 2012: 1
FWCI
2.45
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Particle and Fibre Toxicology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • ArTS Archivio della ricerca di Trieste (University of Trieste https://www.units.it/) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Regione Autonoma Friuli Venezia Giulia
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis
Keywords
asbestos bodies, asbestos fibers, biomineralization, lung tissue, magnesium deposition, ferruginous bodies, elemental distribution, asbestos toxicity, pulmonary fibrosis, X-ray fluorescence microscopy, phase contrast imaging, histopathology
MeSH terms
Asbestos, Asbestosis, Humans, Lung, Microscopy, Fluorescence, Radiography, Spectrometry, X-Ray Emission, X-Rays, Synchrotrons, Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Synchrotron soft X-ray imaging and fluorescence microscopy reveal novel features of asbestos body morphology and composition in human lung tissues. https://app.cochat.ai/papers/10.1186/1743-8977-8-7
The paper
Pascolo, L., Gianoncelli, A., Kaulich, B., Rizzardi, C., Schneider, M., Bottin, C., Polentarutti, M., Kiskinova, M., Longoni, A., & Melato, M. (2011). Synchrotron soft X-ray imaging and fluorescence microscopy reveal novel features of asbestos body morphology and composition in human lung tissues. Particle and Fibre Toxicology. https://doi.org/10.1186/1743-8977-8-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.