Complex permittivity of some ultralow loss dielectric crystals at cryogenic temperatures
Open accessAbstract
Whispering gallery modes were used for very accurate permittivity and dielectric loss measurements of ultralow loss isotropic and uniaxially anisotropic single crystals. Several materials including sapphire, YAG, quartz, and SrLaAlO 4 were measured. The total absolute uncertainty in the real part of permittivity tensor components was estimated to be ±0.1%, limited principally by the uncertainty in sample dimensions. Imaginary parts of permittivities were measured with uncertainties of about 10%, limited by the accuracy of Q -factor measurements of whispering gallery modes. It has been observed that, for most crystals, dielectric losses can be approximated by a power function of absolute temperature only in limited temperature ranges. At temperatures between 4-50 K, losses are often affected by impurities, which are always present in real crystals.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dielectric losses are very low for materials such as sapphire, with a loss tangent of ∼4×10^-8 at 4 K.
“These are very low for materials such as sapphire, with a loss tangent of ∼4 × 10 -8 at 4 K [38].”
From Single Microwave Photon Detection with a Trapped Electron (2016) · cites this paper as [38]
The citation lists haven’t been fetched yet
References 20 · Cited by 315
- Authors
- Krupka, J., Derzakowski, K., Tobar, M., Hartnett, J., & Geyer, R. G.
- Affiliations
- The University of Western Australia (AU)
- National Institute of Standards and Technology (US)
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 10
- Issue
- 5
- Pages
- 387-392
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2080382336
- Cited by
- 315
- References
- 20
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 15 · 2023: 15 · 2022: 20 · 2021: 23 · 2020: 13 · 2019: 8 · 2018: 11 · 2017: 13 · 2016: 15 · 2015: 11 · 2014: 12 · 2013: 10 · 2012: 13
- FWCI
- 9.76
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Measurement Science and Technology (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Electrical and Electromagnetic Research
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Keywords
- complex permittivity, dielectric loss, single crystals, whispering gallery modes, cryogenic temperatures, sapphire, yttrium aluminum garnet, quartz, SrLaAlO4, uniaxial anisotropy, temperature dependence of losses, impurities, quality factor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review