Single Microwave Photon Detection with a Trapped Electron
Open accessAbstract
We investigate theoretically the use of an electron in a Penning trap as a detector of single microwave photons. At the University of Sussex we are developing a chip Penning trap technology, designed to be integrated within quantum circuits. Microwave photons are guided into the trap and interact with the electron’s quantum cyclotron motion. This is an electric dipole transition, where the near field of the microwave radiation induces quantum jumps of the cyclotron harmonic oscillator. The quantum jumps can be monitored using the continuous Stern-Gerlach effect, providing the quantum non demolition signal of the microwave quanta. We calculate the quantum efficiency of photon detection and discuss the main features and technical challenges for the trapped electron as a quantum microwave sensor.
Overview
CoChat Summary
TL;DR
This theoretical paper proposes using a single electron in a planar Penning “geonium chip” as a quantum non-demolition detector of single microwave photons via cyclotron absorption and continuous Stern-Gerlach readout. It derives internal and overall quantum efficiencies, radiative lifetimes, and measurement times, finding that high efficiency requires an open-circuit at the electron and fast phase-based detection of the axial frequency shift.
Key findings
- The electron’s cyclotron frequency can cover \( \omega_p \in 2\pi \times [2.8, 56] \) GHz for \( B_0 \in [0.1, 2] \) T; a typical \( B_0 = 1 \) T and \( V_r = 1.0 \) V gives \( \omega_p = 2\pi \times 28 \) GHz, \( \omega_z = 2\pi \times 30 \) MHz, and \( \omega_m = 2\pi \times 30 \) kHz.
- A cyclotron quantum jump \( \Delta n_p = 1 \) produces an axial frequency shift \( \Delta \omega_z = 2\pi \times 30 \) Hz for \( B_2 = 1.5 \) mT/mm² and \( \omega_z^0 = 2\pi \times 30 \) MHz; the detection is QND, with the microwave quantum recoverable during the radiative lifetime \( \tau_s \).
- Internal quantum efficiency is \( \eta_{\text{internal}} = Y_p/(Y_{\text{CPW}}^L + Y_p) \); an example with \( Y_p \) of a few pS and \( Y_{\text{CPW}}^L \approx 900 \) pS at 4 K gives modest internal quantum efficiencies around 1%–2%, requiring \( Y_{\text{CPW}}^L \to 0 \) for high efficiency.
- Radiative lifetime \( \tau_s \) is a few to hundred seconds for \( y_0 > 1 \) mm and a few hundred ms for \( y_0 \le 1 \) mm; measurement time \( \tau_m \) can be 8 ms for a 10 Hz jump and 80 µs or less for \( \Delta \omega_z \ge 1 \) kHz. Compared with a Cooper Pair Box, the electron’s transition EDM is about 30 times smaller at ~7 GHz, but the electron is not limited by the \( \eta = 0.5 \) lambda three-level bound and could in principle reach 100% quantum efficiency.
Methods
- Theoretical/semi-classical analysis of a single electron in a geonium chip planar Penning trap, with cyclotron motion coupled to an itinerant microwave mode via a coplanar-waveguide transmission line.
- Uses a Hamiltonian of two coupled quantum harmonic oscillators and Fermi’s golden rule to compute photon absorption rates, spontaneous emission rates, characteristic cyclotron admittance, internal quantum efficiency, radiative lifetime, and measurement time from axial phase detection.
- Describes the planned experimental setup: a 4 K pulse-tube cryostat, a planned adiabatic demagnetisation refrigerator to ~80 mK for cyclotron ground-state initialization, UV loading of electrons, and axial motion detection via induced current in a tuned LC circuit with FFT/phase measurement.
Limitations
- Stated in the paper: the calculation ignores photon losses along the CPW, restricts to one photon per detection event and near resonance, uses a semi-classical treatment, and assumes an ideal open-circuit at the electron; minimizing losses and realizing the open-circuit are engineering challenges beyond the article’s scope.
- Stated/evident: the work is theoretical and does not demonstrate a geonium-chip single-microwave-photon detector experimentally; efficiency estimates depend on assumed CPW geometry and dielectric losses, with the example giving only ~1%–2% internal efficiency.
- Evident from the text: performance depends on empirical \( \sigma(\Delta\phi) \) and achievable magnetic bottle strength; the paper notes that open-circuit imperfections or leaks can substantially reduce efficiency, eventually making it vanish, and N-electron enhancement is left for future work.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
15 Valid · 2 Not valid · 31 Not checked · 79 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“However, frequency variations ∆ω z can be determined substantially faster, by recording the phase evolution of the axial motion but without waiting for a full 2π oscillation [26].”
§ Single microwave photon detection with a trapped electron Single microwave photon detection with a trapped electron > •
What the sources say
- Supportedcites [26] Stahl, 2005, Phase-sensitive measurement of trapped particle motions, J. Phys. B At. Mol. Opt. Phys. source
The Novel measurement technique section says that the method determines a frequency difference from the axial motion’s phase difference, without waiting for that difference to reach 360° (2π). It reports about 0.8 s per phase-sensitive measurement versus 5.6 s for an absolute-frequency measurement under the same conditions. The 2π threshold refers to accumulated phase difference, not one cycle of axial motion. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The cyclotron and magnetron frequencies can be accurately obtained through the axial detection signal, by means of the mode-coupling technique [24].”
§ Single microwave photon detection with a trapped electron Single microwave photon detection with a trapped electron > •
What the sources say
- Partly supportedcites [24] Alonso, 2004, Determination of the g-factor of single hydrogen-like ions by mode coupling in a Penning trap, Physica Scripta sourceExperimental — accuracy not yet measured
Section 2.2 describes detecting a split axial resonance during mode coupling, and Section 3 calculates the modified cyclotron frequency from the measured axial frequencies and the applied coupling frequency. Section 3 says the magnetron frequency is measured separately in both traps; it does not establish that the magnetron frequency is obtained through the axial detection signal by mode coupling. Page numbers are unavailable in our copy. (LLM, conf=0.86)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“At the University of Sussex we have developed a planar Penning trap, which is derived from the projection of the 3D cylindric trap onto the flat surface of a chip [11,12].”
§ Single microwave photon detection with a trapped electron Single microwave photon detection with a trapped electron > 1. Introduction
What the sources say
- Supportedcites [11] 2011, Theory of the coplanar waveguide Penning trap, New J. Phys. source
Verdú’s Sussex affiliation appears in the paper’s opening information. The abstract presents a novel planar Penning trap derived by projecting a three-dimensional cylindrical trap onto a chip, and Section 2 describes that projection in detail. The paper supports development of the trap design; it does not claim an experimental device was built. (LLM, conf=0.92)
- Not checked — no full text of the sourcecites [12] Pinder, 2013, A planar Penning trap with tunable dimensionality of the trapping potential, Int. J. Mass Spectrom. source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In the early experiments of [26] quantum jumps of 100 mHz were determined in 800 ms, with σ(∆φ) = 45 • .”
§ Single microwave photon detection with a trapped electron Single microwave photon detection with a trapped electron > 5.2. Measurement Time of ∆ω z
What the sources say
- Partly supportedcites [26] Stahl, 2005, Phase-sensitive measurement of trapped particle motions, J. Phys. B At. Mol. Opt. Phys. sourceExperimental — accuracy not yet measured
The Conclusion reports detecting a frequency difference around 100 mHz in about 0.8 s per data point. But Section 3 says the spin-state changes were simulated, not observed quantum jumps, and identifies approximately 45° as the separation between the measured phases, not the uncertainty σ(∆φ). (LLM, conf=0.90)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“As explained in [26], the measurement time is given by the following simple expression: τ m = σ(∆φ) ∆ω z(20)”
§ Single microwave photon detection with a trapped electron Single microwave photon detection with a trapped electron > 5.2. Measurement Time of ∆ω z
What the sources say
- Supportedcites [26] Stahl, 2005, Phase-sensitive measurement of trapped particle motions, J. Phys. B At. Mol. Opt. Phys. source
Section 3, equation (6), gives the frequency resolution as f = σ(φ)/(2πT), where T is measurement time. Expressing the frequency difference as an angular frequency, Δω_z = 2πf, yields the claimed τ_m = σ(Δφ)/Δω_z. (LLM, conf=0.90)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
90 more claims · 4 with their cited sources checked
Create a free account to see all 127 claims and every source verdict.
- Probably not a substantial claim. 13
- It may state two separate claims as one. 23
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Another very important configuration is the magnetic bottle, defined as B = (B z,0 ≠ 0, 0, B z,020 ≠ 0, 0).”
From Planar, strong magnetic field source for a chip ion trap (2020) · cites this paper as [13]
Citations
Cites
Pozar, D. M. (1990) · Cited by 8,676
Strong coupling of a single photon to a superconducting qubit using circuit quantum electrodynamics
Wallraff, A., Schuster, D. I., Blais, A., Frunzio, L., Huang, R. S., Majer, J., Kumar, S., Girvin, S. M., & Schoelkopf, R. J. (2004) · Nature · doi:10.1038/nature02851 · Cited by 3,796 · cited 1×
“In particular, a Cooper Pair Box (CPB) has a typical transition EDM of dCPB = 20, 000 atomic units ('36,000 D) [39,40].”
BackgroundSakurai, J. J., & Napolitano, J. (2020) · Cambridge University Press eBooks · doi:10.1017/9781108587280 · Cited by 3,666
Blais, A., Huang, R.-S., Wallraff, A., Girvin, S. M., & Schoelkopf, R. J. (2004) · Physical Review A · doi:10.1103/physreva.69.062320 · Cited by 2,989 · cited 2×
“In particular, a Cooper Pair Box (CPB) has a typical transition EDM of dCPB = 20, 000 atomic units ('36,000 D) [39,40].”
BackgroundGeonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367 · cited 4×
“In general the cyclotron frequency has some dependence on the applied electrostatic voltages, however ωp is mainly determined by the strength of the magnetic field [27].”
BackgroundMethodInfluential(1991) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,028
Complex permittivity of some ultralow loss dielectric crystals at cryogenic temperatures
Krupka, J., Derzakowski, K., Tobar, M., Hartnett, J., & Geyer, R. G. (1999) · Measurement Science and Technology · doi:10.1088/0957-0233/10/5/308 · Cited by 315 · cited 2×
“, well below the 4 K used in [38]), might significantly increase these values.”
BackgroundExperiments with an isolated subatomic particle at rest
Dehmelt, H. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.525 · Cited by 302
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281 · cited 1×
“from quantum information with trapped electrons or laser-cooled ions [13] to Fourier-Transform Ion Cyclotron Resonance mass spectrometry [14].”
MethodPeil, S., & Gabrielse, G. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.1287 · Cited by 209 · cited 10×
“At 4 K the electron’s cyclotron oscillator is typically several quanta above the ground state [5].”
BackgroundMethodInfluential
Cited by
Gaussian state-based quantum illumination with simple photodetection
Yang, H., Roga, W., Pritchard, J. D., & Jeffers, J. (2021) · Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) · Cited by 21
Gaussian state-based quantum illumination with simple photodetection
Yang, H., Roga, W., Pritchard, J. D., & Jeffers, J. (2021) · Optics Express · doi:10.1364/oe.416151 · Cited by 26
Broadband Coaxial S-Parameter Measurements for Cryogenic Quantum Technologies
Shin, S.-H., Stanley, M., Skinner, J., de Graaf, S. E., & Ridler, N. (2023) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2023.3322909 · Cited by 20
“Microwave components commonly used at mK temperatures for these applications are attenuators, circulators, isolators, etc. [2], [3].”
BackgroundSuperconducting Flux Pump for a Planar Magnetic Field Source
Lacy, J. H., Cridland, A., Pinder, J., Uribe, A., Willetts, R., & Verdu, J. (2020) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2020.3004768 · Cited by 12
“The planar geometry of the Geonium Chip offers several advantages over current Penning trap systems, and is being developed for mass spectrometry [19], single microwave photon detection [20], and microwave quantum illumination [21].”
MethodSelf-citationThe quantum theory of the Penning trap
Crimin, F., Garraway, B. M., & Verdú, J. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2017.1393570 · Cited by 10
Self-citation
Metadata
- Authors
- Cridland, A., Lacy, J., Pinder, J., & Verdú, J.
- Affiliations
- Department of Physics and Astronomy, University of Sussex, Falmer BN1 9QH, UK
- University of Sussex (GB)
- Corresponding author
- Verdú, José
- Venue
- Photonics
- Publisher
- MDPI AG
- Published
- 2016-11-19
- Volume
- 3
- Issue
- 4
- Pages
- 59
- ISSN
- 2304-6732 (ISSN-L)
- OpenAlex
- W2556536106
- Cited by
- 18
- References
- 37
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 3 · 2018: 1 · 2017: 1
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Photonics (publishedVersion, cc-by)
- Figshare (submittedVersion, cc-by)
- Sussex Research Online (University of Sussex) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Engineering and Physical Sciences Research Council (EP/N003675/1)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Mechanics and Applications
- Keywords
- single-photon detection, Penning trap, microwave photon detection, cyclotron motion, electric dipole transitions, quantum jumps, quantum nondemolition detection, quantum efficiency, quantum circuits
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single Microwave Photon Detection with a Trapped Electron. https://app.cochat.ai/papers/10.3390/photonics3040059
- The paper
- Cridland, A., Lacy, J., Pinder, J., & Verdú, J. (2016). Single Microwave Photon Detection with a Trapped Electron. Photonics. https://doi.org/10.3390/photonics3040059
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.