The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Optical halide sensing using fluorescence quenching: theory, simulations and applications - a review
Open accessAbstract
In the last century the production and application of halides assumed an ever greater importance. In the fields of medicine, dentistry, plastics, pesticides, food, photography etc many new halogen containing compounds have come into everyday use. In an analogous manner many techniques for the detection and determination of halogen compounds and ions have been developed with scientific journals reporting ever more sensitive methods. The 19th century saw the discovery of what is now thought of as a classical method for halide determination, namely the quenching of fluorescence. However, little analytically was done until over 100 years after its discovery, when the first halide sensors based on the quenching of fluorescence started to emerge. Due to the typical complexity of fluorescence quenching kinetics of optical halide sensors and their lack of selectivity, they have found little if any place commercially, despite their sensitivity, where other techniques such as ion-selective electrodes, x-ray fluorescence spectroscopy and colorimetry have dominated the analytical market. In this review article the author summarizes the relevant theory and work to date for halide sensing using fluorescence quenching methods and outlines the future potential that fluorescence quenching based optical sensors have to offer in halide determination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of the Cystic Fibrosis Gene: Genetic Analysis
Kerem, B.-S., Rommens, J. M., Buchanan, J. A., Markiewicz, D., Cox, T. K., Chakravarti, A., Buchwald, M., & Tsui, L.-C. (1989) · Science · doi:10.1126/science.2570460 · Cited by 4,142
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434
Cited by
Exciton diffusion in organic semiconductors
Mikhnenko, O. V., Blom, P. W. M., & Nguyen, T.-Q. (2015) · Energy & Environmental Science · doi:10.1039/c5ee00925a · Cited by 997
Gehlen, M. H. (2020) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2019.100338 · Cited by 734
(2006) · Principles of Fluorescence Spectroscopy · doi:10.1007/978-0-387-46312-4_8 · Cited by 278
An indirect approach for anion detection: the displacement strategy and its application
Lou, X., Ou, D., Li, Q., & Li, Z. (2012) · Chemical Communications · doi:10.1039/c2cc33158f · Cited by 272
Metadata
- Authors
- Geddes, C. D.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2001-08-02
- Volume
- 12
- Issue
- 9
- Pages
- R53-R88
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2147444097
- Cited by
- 271
- References
- 2
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical halide sensing using fluorescence quenching: theory, simulations and applications - a review. https://app.cochat.ai/papers/10.1088/0957-0233/12/9/201
- The paper
- Geddes, C. D. (2001). Optical halide sensing using fluorescence quenching: theory, simulations and applications - a review. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/12/9/201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.