The DOI matches its Crossref record.
Data analysis for optical sensors based on spectroscopy of surface plasmons
Abstract
We have examined the noise sources for a surface plasmon resonance (SPR) sensor system to facilitate optimization of SPR sensor instrumentation and data-processing methods for high-resolution SPR sensing. We found detector shot noise to be the dominant source of noise in the SPR sensor, and investigated the propagation of noise through a commonly used SPR sensor data-processing algorithm. Deriving an expression relating the detector noise level to the noise of the output data, we used measurements of the magnitude and distribution of both charge-coupled device and photodiode array detector noise to predict the noise levels observed in the sensor output. We used this method to optimize the parameters of the algorithm and introduced a modified algorithm with enhanced resistance to correlated light level noise. In addition, we evaluated the noise performance of alternative SPR sensor designs, including a sensor with no polarization optics and another with optics producing an inverted SPR absorption feature. Experimental SPR sensor data demonstrated good agreement with predicted noise levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Self-citationPresent and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Self-citationSurface plasmon resonance (SPR) sensors: approaching their limits?
Piliarik, M., & Homola, J. (2009) · Optics Express · doi:10.1364/oe.17.016505 · Cited by 692
Self-citationImproving the Instrumental Resolution of Sensors Based on Localized Surface Plasmon Resonance
Dahlin, A. B., Tegenfeldt, J. O., & Höök, F. (2006) · Analytical Chemistry · doi:10.1021/ac0601967 · Cited by 329
Nanoscale Refractive Index Sensors with High Figures of Merit via Optical Slot Antennas
Gao, B., Wang, Y., Zhang, T., Xu, Y., He, A., Dai, L., & Zhang, J. (2019) · ACS Nano · doi:10.1021/acsnano.9b03406 · Cited by 25
Metadata
- Authors
- Nenninger, G. G., Piliarik, M., & Homola, J.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2002-11-04
- Volume
- 13
- Issue
- 12
- Pages
- 2038-2046
- ISSN
- 0957-0233 (ISSN-L)
- OpenAlex
- W1978033220
- Cited by
- 181
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Data analysis for optical sensors based on spectroscopy of surface plasmons. https://app.cochat.ai/papers/10.1088/0957-0233/13/12/332
- The paper
- Nenninger, G. G., Piliarik, M., & Homola, J. (2002). Data analysis for optical sensors based on spectroscopy of surface plasmons. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/13/12/332
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.