Defocusing digital particle image velocimetry and the three-dimensional characterization of two-phase flows
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Defocusing digital particle image velocimetry (DDPIV) is the natural extension of planar PIV techniques to the third spatial dimension. In this paper we give details of the defocusing optical concept by which scalar and vector information can be retrieved within large volumes. The optical model and computational procedures are presented with the specific purpose of mapping the number density, the size distribution, the associated local void fraction and the velocity of bubbles or particles in two-phase flows. Every particle or bubble is characterized in terms of size and of spatial coordinates, used to compute a true three-component velocity field by spatial three-dimensional cross-correlation. The spatial resolution and uncertainty limits are established through numerical simulations. The performance of the DDPIV technique is established in terms of number density and void fraction. Finally, the velocity evaluation methodology, using the spatial cross-correlation technique, is described and discussed in terms of velocity accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Digital particle image velocimetry
Willert, C. E., & Gharib, M. (1991) · Experiments in Fluids · doi:10.1007/bf00190388 · Cited by 1,991 · cited 4×
“The technique naturally evolved to digital recording when electronic components such as charge coupled devices (CCD) became commercially available (Cho 1989, Willert and Gharib 1991 ).”
MethodInfluentialSelf-citationFundamentals of digital particle image velocimetry
Westerweel, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/002 · Cited by 1,425 · cited 2×
“Various authors (see, for example, Westerweel 1997) have addressed some of these issues, which are beyond the goal of this work.”
BackgroundMethodTheory of cross-correlation analysis of PIV images
Keane, R. D., & Adrian, R. J. (1992) · Flow Turbulence and Combustion · doi:10.1007/bf00384623 · Cited by 1,227
Optimization of particle image velocimeters. I. Double pulsed systems
Keane, R. D., & Adrian, R. J. (1990) · Measurement Science and Technology · doi:10.1088/0957-0233/1/11/013 · Cited by 816
Distortion compensation for generalized stereoscopic particle image velocimetry
Soloff, S. M., Adrian, R. J., & Liu, Z.-C. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/008 · Cited by 674
Efficient detection of spurious vectors in particle image velocimetry data
Westerweel, J. (1994) · Experiments in Fluids · doi:10.1007/bf00206543 · Cited by 486 · cited 1×
“Initially proposed by Keane and Adrian (1992) and later extended to DPIV by Westerweel et al (1997), this technique, now standard in PIV applications, improves the estimation of the displacement-correlation peak.”
MethodWesterweel, J., Dabiri, D., & Gharib, M. (1997) · Experiments in Fluids · doi:10.1007/s003480050082 · Cited by 476 · cited 1×
“Initially proposed by Keane and Adrian (1992) and later extended to DPIV by Westerweel et al (1997) , this technique, now standard in PIV applications, improves the estimation of the displacement-correlation peak.”
MethodSelf-citationStereoscopic particle image velocimetry applied to liquid flows
Prasad, A. K., & Adrian, R. J. (1993) · Experiments in Fluids · doi:10.1007/bf00195595 · Cited by 317
Scheimpflug stereocamera for particle image velocimetry in liquid flows
Prasad, A. K., & Jensen, K. (1995) · Applied Optics · doi:10.1364/ao.34.007092 · Cited by 264
Hart, D. P. (2000) · Laser Techniques Applied to Fluid Mechanics · doi:10.1007/978-3-642-56963-0_2 · Cited by 251 · cited 1×
“though, non-post-interrogation approaches have also been reported ( Hart 2000 ).”
BackgroundOn the performance of particle tracking
Agüí, J. C., & Jiménez, J. (1987) · Journal of Fluid Mechanics · doi:10.1017/s0022112087003252 · Cited by 219
Turbulent flow measurement in a square duct with hybrid holographic PIV
Zhang, J., Tao, B., & Katz, J. (1997) · Experiments in Fluids · doi:10.1007/s003480050124 · Cited by 185 · cited 2×
“To minimize the sensitivity to speckle noise and to improve the scattering efficiency, Zhang et al (1997) devised a novel configuration to perform turbulent flow measurement in a square duct and used PIV to interrogate the hologram.”
Method3D scanning PIV applied to an air flow in a motored engine using digital high-speed video
Brücker, C. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/011 · Cited by 118 · cited 3×
“…and Riethmuller 1988), translational (Prasad and Adrian 1993), single camera setup (Reese et al 1995), Scheimpflug arrangement (Prasad and Jensen 1995), in-line (Grant et al 1995), multilayer (Raffel et al 1996, Abe et al 1998), scanning (Brücker 1997), multiplane (Kähler and Kompenhans 2000).”
BackgroundMethodOn the structure of a two-dimensional wake behind a pair of flat plates
Higuchi, H., Lewalle, J., & Crane, P. H. G. (1994) · Physics of Fluids · doi:10.1063/1.868084 · Cited by 48 · cited 1×
“Although local peak detection techniques are common in image processing literature (Higuchi et al 1994), a new algorithm is proposed to overcome the practical problems of particle overlapping, residual background noise and nonuniformity of illumination.”
BackgroundThe application of an in-line, stereoscopic, PIV system to 3-component velocity measurements
Grant, I., Fu, S., Pan, X., & Wang, X. (1995) · Experiments in Fluids · doi:10.1007/bf00189710 · Cited by 28 · cited 1×
“…and Riethmuller 1988), translational (Prasad and Adrian 1993), single camera setup (Reese et al 1995), Scheimpflug arrangement (Prasad and Jensen 1995), in-line (Grant et al 1995), multilayer (Raffel et al 1996, Abe et al 1998), scanning (Brücker 1997), multiplane (Kähler and Kompenhans 2000).”
Background
Cited by
Twenty years of particle image velocimetry
Adrian, R. J. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0991-7 · Cited by 1,267
Riethmuller, M., David, L., & Lecordier, B. (2012) · Laser Velocimetry in Fluid Mechanics · doi:10.1002/9781118569610.ch6 · Cited by 516
Cierpka, C., & Kähler, C. J. (2012) · Journal of Visualization · doi:10.1007/s12650-011-0107-9 · Cited by 450
Holographic particle image velocimetry: from film to digital recording
Meng, H., Pan, G., Pu, Y., & Woodward, S. H. (2004) · Measurement Science and Technology · doi:10.1088/0957-0233/15/4/009 · Cited by 215
“Unlike defocusing (Pereira and Gharib 2002) or scanning PIV, HPIV relies on holography—an intrinsic 3D imaging process—to record and retrieve 3D images of the tracer particles, from which 3D displacements of the particles over two exposures separated by a brief time interval are extracted.”
Two-frame 3D particle tracking
Pereira, F., Stüer, H., Graff, E. C., & Gharib, M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/7/006 · Cited by 173
Self-citation
Metadata
- Authors
- Pereira, F., & Gharib, M.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2002-03-28
- Volume
- 13
- Issue
- 5
- Pages
- 683-694
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2162513169
- Cited by
- 196
- References
- 16
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.