Abstract
Holographic particle image velocimetry (HPIV) offers potentially the best solution to volumetric measurements of the three-dimensional velocity fields in complex flows. However, the traditional film-based HPIV measurement is rather cumbersome, limiting its use to only a handful of groups worldwide. The newly emerged digital HPIV revolutionizes flow measurement science by providing a practical 3D velocimetry tool. It commands simple hardware that is similar to regular two-dimensional particle image velocimetry (PIV), yet it provides continuous (time-series) three-dimensional, three-component flow field data. Not only is the need for chemical processing eliminated, but also the cumbersome optical reconstruction is completely replaced by numerical reconstruction algorithms. Several breakthroughs have led to the development of the first practical and integrated digital HPIV systems. To explain the transition from film to digital recording, fundamental issues in HPIV are reviewed in this paper. Axial accuracy in HPIV measurement is ultimately limited by an inherent depth-of-focus problem, while information capacity is limited by inherent speckle noise. Information capacity is an important concept in HPIV, comprising the maximum acceptable seeding density multiplied by the sample volume depth along the optic axis. Both the axial accuracy and the information capacity are limited by the effective hologram aperture. The pursuit of a large hologram aperture in the past has resulted in further complexity in film-based HPIV systems. Digital HPIV, on the other hand, enjoys great simplicity of implementation and operation. A digital HPIV is also far more compact and rugged compared to existing film-based HPIV systems, making it suitable for duplication and commercialization. However, since digital sensors suffer from inferior pixel resolutions compared to films, the effective hologram aperture is much smaller in digital HPIV than that achievable in film-based HPIV. Alleviating this problem, digital HPIV also presents new possibilities in data processing such as the use of the complex amplitude of the reconstructed light wave to improve depth sensitivity and signal-to-noise ratio. Two examples of digital HPIV systems and measurement results are given. We believe digital HPIV can revitalize holographic particle imaging and bring it into the mainstream in much the same way that digital PIV brought PIV into widespread use a decade ago.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Introduction to Fourier Optics
Sutton, P. (1996) · Quantum and Semiclassical Optics: Journal of the European Optical Society Part B · doi:10.1088/1355-5111/8/5/014 · Cited by 4,934
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405 · cited 1×
“Prior to that transition, film-based PIV had been developed for over a decade (Pickering and Halliwell 1985) and PIV theory was well established (Adrian 1991).”
Digital particle image velocimetry
Willert, C. E., & Gharib, M. (1991) · Experiments in Fluids · doi:10.1007/bf00190388 · Cited by 1,991 · cited 1×
“However, PIV took off as a widely embraced tool only after its digital implementation (Willert and Gharib 1991) matured in the mid1990s (Westerweel 1997).”
Fundamentals of digital particle image velocimetry
Westerweel, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/002 · Cited by 1,425 · cited 1×
“However, PIV took off as a widely embraced tool only after its digital implementation (Willert and Gharib 1991) matured in the mid1990s (Westerweel 1997).”
Phase-conjugate holographic system for high-resolution particle-image velocimetry
Barnhart, D. H., Adrian, R. J., & Papen, G. C. (1994) · Applied Optics · doi:10.1364/ao.33.007159 · Cited by 236 · cited 1×
“Several other groups have also successfully produced instantaneous, highspatial resolution, volumetric velocity field measurements of turbulent flows (Barnhart et al 1994, Zhang et al 1997, Sheng et al 2003, Hermann and Hinsch 2003).”
Pereira, F., & Gharib, M. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/5/305 · Cited by 196 · cited 2×
“Unlike defocusing (Pereira and Gharib 2002) or scanning PIV, HPIV relies on holography—an intrinsic 3D imaging process—to record and retrieve 3D images of the tracer particles, from which 3D displacements of the particles over two exposures separated by a brief time interval are extracted.”
Turbulent flow measurement in a square duct with hybrid holographic PIV
Zhang, J., Tao, B., & Katz, J. (1997) · Experiments in Fluids · doi:10.1007/s003480050124 · Cited by 185 · cited 2×
“Several other groups have also successfully produced instantaneous, highspatial resolution, volumetric velocity field measurements of turbulent flows (Barnhart et al 1994, Zhang et al 1997, Sheng et al 2003, Hermann and Hinsch 2003).”
Inverse solutions for electrical impedance tomography based on conjugate gradients methods
Wang, M. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/1/314 · Cited by 178
Coëtmellec, S., Lebrun, D., & Özkul, C. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.001537 · Cited by 56 · cited 1×
“This not only eliminates the need for chemical processing, but also completely replaces the cumbersome optical reconstruction through numerical reconstruction algorithms (Sun et al 2002, Coetmellec et al 2002, Xu et al 2002).”
A new particle tracking algorithm based on deterministic annealing and alternative distance measures
Stellmacher, M., & Obermayer, K. (2000) · Experiments in Fluids · doi:10.1007/s003480050412 · Cited by 50 · cited 2×
“For velocity extraction we used a powerful particle matching (PM) algorithm (Stellmacher and Obermayer 2000) which operates on particle 3D coordinate data.”
Intrinsic aberrations due to Mie scattering in particle holography
Pu, Y., & Meng, H. (2003) · Journal of the Optical Society of America A · doi:10.1364/josaa.20.001920 · Cited by 48 · cited 6×
“More details about intrinsic aberration in HPIV can be found in Pu and Meng (2003).”
InfluentialSelf-citation
Cited by
Applications of Holography in Fluid Mechanics and Particle Dynamics
Katz, J., & Sheng, J. (2010) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-121108-145508 · Cited by 461
Cierpka, C., & Kähler, C. J. (2012) · Journal of Visualization · doi:10.1007/s12650-011-0107-9 · Cited by 450
High-Speed Imaging of Drops and Bubbles
Thoroddsen, S. T., Etoh, T. G., & Takehara, K. (2008) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102215 · Cited by 417
Off-axis digital hologram reconstruction: some practical considerations
Verrier, N., & Atlan, M. (2011) · Applied Optics · doi:10.1364/ao.50.00h136 · Cited by 183
Metadata
- Authors
- Meng, H., Pan, G., Pu, Y., & Woodward, S. H.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2004-03-19
- Volume
- 15
- Issue
- 4
- Pages
- 673-685
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2088635576
- Cited by
- 215
- References
- 13
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.