CoChat

PIV optimization for the study of turbulent flow using spectral analysis

Foucaut, J M, Carlier, J, Stanislas, M · 2004 · Measurement Science and Technology
Cited by 205

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Particle image velocimetry (PIV) is a measurement technique which is well adapted to the study of the structure of turbulent flows, as it allows us to obtain quantitative information on the spatial structure of the velocity field. This contribution presents an experimental approach to characterize the measurement noise of a PIV system and the spatial response of such a method. This approach is based on a specific spectral analysis of the velocity vector field deduced from several PIV experiments. This study was done in two steps. The first step was to measure the noise level of PIV and to determine a model for the PIV transfer function from a series of displacement fields measured in a quiet liquid. This model shows the effect of the interrogation window size and introduces a spectral noise density which is constant for a given recording set-up. The second step was to compute spectra from velocity fields obtained in a turbulent boundary layer in a plane parallel to the wall. These spectra show that PIV behaves as a band pass filter. This series of experiments allows us to build a model for the prediction of the PIV spectrum knowing the real one. This model confirms that the PIV noise is white. It allows us to optimize the interrogation window size in order to obtain the best compromise between the spectral response and the spatial resolution. The rms value of the noise can be estimated from the noise density, allowing us to quantify the measurement accuracy. The improvement of sub-pixel window shift is also discussed, leading to a small decrease in the noise level. An analysis is proposed to identify the main sources of noise: particles cut by the border of the interrogation window, isolated particles, etc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-0233/15/6/003

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 205

Metadata

Authors
Foucaut, J. M., Carlier, J., & Stanislas, M.
Venue
Measurement Science and Technology
Published
2004-05-14
Volume
15
Issue
6
Pages
1046-1058
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2034368317
Cited by
205
References
14
FWCI
5.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: PIV optimization for the study of turbulent flow using spectral analysis. https://app.cochat.ai/papers/10.1088/0957-0233/15/6/003
The paper
Foucaut, J. M., Carlier, J., & Stanislas, M. (2004). PIV optimization for the study of turbulent flow using spectral analysis. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/15/6/003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.