Methods for in-field user calibration of an inertial measurement unit without external equipment
Abstract
This paper presents methods to calibrate and compensate for non-zero biases, non-unit scale factors, axis misalignments and cross-axis sensitivities of both the tri-axial accelerometer and gyroscopic setups in a micro-electro-mechanical systems (MEMS) based inertial measurement unit (IMU). These methods depend on the Earth's gravity as a stable physical calibration standard. Specifically, the calibration of gyroscopes is significantly improved by comparing the outputs of the accelerometer and the IMU orientation integration algorithm, after arbitrary motions. The derived property and proposed cost function allow the gyroscopes to be calibrated without external equipment, such as a turntable, or requiring precise maneuvers. Both factors allow the IMU to be easily calibrated by the user in the field so that it can function as an accurate orientation sensor. A custom-made prototype IMU is used to demonstrate the effectiveness of the proposed methods, with data that are carefully obtained using prescribed motions, as well as those less rigorously collected from the IMU when it is mounted on the head of a user or held in hands with brief random movements. With calibration, the observed average static angular error is less than a quarter of a degree and the dynamic angular error is reduced by a factor of 2 to 5.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Camomilla, V., Bergamini, E., Fantozzi, S., & Vannozzi, G. (2018) · Sensors · doi:10.3390/s18030873 · Cited by 591
In-Car Positioning and Navigation Technologies—A Survey
Skog, I., & Handel, P. (2009) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2008.2011712 · Cited by 582
A robust and easy to implement method for IMU calibration without external equipments
Tedaldi, D., Pretto, A., & Menegatti, E. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907297 · Cited by 252
Metadata
- Authors
- Fong, W. T., Ong, S. K., & Nee, A. Y. C.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2008-07-10
- Volume
- 19
- Issue
- 8
- Pages
- 085202
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2000754062
- Cited by
- 228
- References
- 0
- FWCI
- 15.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods for in-field user calibration of an inertial measurement unit without external equipment. https://app.cochat.ai/papers/10.1088/0957-0233/19/8/085202
- The paper
- Fong, W. T., Ong, S. K., & Nee, A. Y. C. (2008). Methods for in-field user calibration of an inertial measurement unit without external equipment. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/19/8/085202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.