The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
A robust and easy to implement method for IMU calibration without external equipments
Abstract
Motion sensors as inertial measurement units (IMU) are widely used in robotics, for instance in the navigation and mapping tasks. Nowadays, many low cost micro electro mechanical systems (MEMS) based IMU are available off the shelf, while smartphones and similar devices are almost always equipped with low-cost embedded IMU sensors. Nevertheless, low cost IMUs are affected by systematic error given by imprecise scaling factors and axes misalignments that decrease accuracy in the position and attitudes estimation. In this paper, we propose a robust and easy to implement method to calibrate an IMU without any external equipment. The procedure is based on a multi-position scheme, providing scale and misalignments factors for both the accelerometers and gyroscopes triads, while estimating the sensor biases. Our method only requires the sensor to be moved by hand and placed in a set of different, static positions (attitudes). We describe a robust and quick calibration protocol that exploits an effective parameterless static filter to reliably detect the static intervals in the sensor measurements, where we assume local stability of the gravity's magnitude and stable temperature. We first calibrate the accelerometers triad taking measurement samples in the static intervals. We then exploit these results to calibrate the gyroscopes, employing a robust numerical integration technique. The performances of the proposed calibration technique has been successfully evaluated via extensive simulations and real experiments with a commercial IMU provided with a calibration certificate as reference data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FrameSLAM: From Bundle Adjustment to Real-Time Visual Mapping
Konolige, K., & Agrawal, M. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2004832 · Cited by 532
Fundamentals Of High Accuracy Inertial Navigation
Chatfield, A. B. (1997) · American Institute of Aeronautics and Astronautics eBooks · doi:10.2514/4.866463 · Cited by 427
A new multi-position calibration method for MEMS inertial navigation systems
Syed, Z. F., Aggarwal, P., Goodall, C., Niu, X., & El-Sheimy, N. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/7/016 · Cited by 386
Methods for in-field user calibration of an inertial measurement unit without external equipment
Fong, W. T., Ong, S. K., & Nee, A. Y. C. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/8/085202 · Cited by 228
Procedure for in-use calibration of triaxial accelerometers in medical applications
Lötters, J. C., Schipper, J., Veltink, P. H., Olthuis, W., & Bergveld, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)00049-1 · Cited by 203
Attitude estimation on SO[3] based on direct inertial measurements
Hamel, T., & Mahony, R. E. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642025 · Cited by 195
Calibration of a MEMS inertial measurement unit
Skog, I., & Händel, P. (2006) · Cited by 163
Feedback control for robotic manipulator with an uncertain Jacobian matrix
Cheah, C. C., Kawamura, S., & Arimoto, S. (1999) · Journal of Robotic Systems · doi:10.1002/(sici)1097-4563(199902)16:2<81::aid-rob2>3.0.co;2-9 · Cited by 135
Initial calibration of an inertial measurement unit using an optical position tracking system
Kim, A., & Golnaraghi, M. F. (2004) · doi:10.1109/plans.2004.1308980 · Cited by 94
IMU Self-Calibration Using Factorization
Hwangbo, M., Kim, J., & Kanade, T. (2013) · IEEE Transactions on robotics · doi:10.1109/tro.2012.2230994 · Cited by 58
Cited by
Using Inertial Sensors for Position and Orientation Estimation
Kok, M., Hol, J. D., & Schön, T. B. (2017) · Foundations and Trends® in Signal Processing · doi:10.1561/2000000094 · Cited by 347
Cereatti, A., Gurchiek, R., Mündermann, A., Fantozzi, S., Horak, F., Delp, S., & Aminian, K. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112225 · Cited by 79
IMU-Based Monitoring for Assistive Diagnosis and Management of IoHT: A Review
Bo, F., Yerebakan, M., Dai, Y., Wang, W., Li, J., Hu, B., & Gao, S. (2022) · Healthcare · doi:10.3390/healthcare10071210 · Cited by 35
Metadata
- Authors
- Tedaldi, D., Pretto, A., & Menegatti, E.
- Venue
- 2014 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2014-05
- Pages
- 3042-3049
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2021503353
- Cited by
- 252
- References
- 14
- FWCI
- 17.44
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A robust and easy to implement method for IMU calibration without external equipments. https://app.cochat.ai/papers/10.1109/icra.2014.6907297
- The paper
- Tedaldi, D., Pretto, A., & Menegatti, E. (2014). A robust and easy to implement method for IMU calibration without external equipments. 2014 IEEE International Conference on Robotics and Automation (ICRA). https://doi.org/10.1109/icra.2014.6907297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.