CoChat

A novel method to fabricate micro-gratings applied for deformation measurement around a crack in a thin film

Wu, Dan, Xie, Huimin, Dai, Xianglu, Wang, Rong · 2014 · Measurement Science and Technology

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

The grating fabrication technique has been of great concern in the use of the grating based deformation measurement method. Although various methods have been developed to effectively fabricate gratings, few are able to fabricate gratings directly onto thin films. In this paper, a novel grating fabricating method using focused ion beam deposition is proposed. The advantage of this method is that it causes smaller damage to the surface of the specimen compared with other methods and is especially suitable for deformation measurement of thin films at micro-scales. The fabricated micro-gratings that have been produced by this method have been used to measure the deformation around a crack in an aluminum film supported on a PDMS substrate. The deformation during the crack propagation has been measured with the fabricated micro-grating and the results indicate that this method is feasible to measure the deformation of thin films at micro-scales. It should also be noted that this method can be used to fabricate gratings on various substrates at micro-scales. The successful results indicate that this method is reliable and suitable for deformation measurement at micro-scales.

Overview

Integrity signals

Registry

Crossref · 10.1088/0957-0233/25/2/025012

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 24 references

Research works printed but not linked: 7

  1. Li C, 2013, Meas. Sci. Technol., 24
  2. Takei S, Appl. Phys. Express, 3
  3. Li Y, 2010, J. Micromech. Microeng., 20
  4. Li Y, 2011, Meas. Sci. Technol., 22
  5. Tang M, 2010, Meas. Sci. Technol., 21
  6. Jiang M, 2012, Chin. Phys. Lett., 29
  7. Wu D, 2013, J. Micromech. Microeng., 23

Cited by

See all 16

Metadata

Authors
Wu, D., Xie, H., Dai, X., & Wang, R.
Affiliations
Tsinghua University (CN)
Corresponding author
Xie, Huimin
Venue
Measurement Science and Technology
Published
2014-01-09
Volume
25
Issue
2
Pages
025012
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2068574168
Cited by
14
References
24
Citations by year
2026: 2 · 2024: 1 · 2021: 3 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 2
FWCI
2.39
Type
journal article
Language
en
Open access
closed
Licence
Locations
Measurement Science and Technology (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
  • Physical Sciences › Engineering › Mechanics of Materials › Metal and Thin Film Mechanics
  • Physical Sciences › Engineering › Mechanics of Materials › Fatigue and fracture mechanics
Keywords
focused ion beam deposition, deformation measurement, thin films, crack propagation, aluminum thin films, PDMS substrate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel method to fabricate micro-gratings applied for deformation measurement around a crack in a thin film. https://app.cochat.ai/papers/10.1088/0957-0233/25/2/025012
The paper
Wu, D., Xie, H., Dai, X., & Wang, R. (2014). A novel method to fabricate micro-gratings applied for deformation measurement around a crack in a thin film. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/25/2/025012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.