The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Recent advances in displacement measuring interferometry
Abstract
The present state of high-resolution displacement measuring interferometry is reviewed. Factors which determine the accuracy, linearity and repeatability of nanometre-scale measurements are emphasized. Many aspects of interferometry are discussed, including general metrology and alignment errors, as well as path length errors. Optical mixing and the nonlinear relation between phase and displacement are considered, as well as the influence of diffraction on accuracy. Environmental stability is a major factor in the repeatability and accuracy of measurement. It is difficult to obtain a measurement accuracy of 10 -7 when working in air. Several approaches to improving this situation are described, including multiwavelength interferometry. Recent measurements of the short- and long-term frequency stability of lasers are summarized. Optical feedback is a subtle, but important source of frequency destabilization, and methods of detection and isolation are reviewed. Calibration of phase measuring electronics used for subfringe interpolation is included. Progress in 'in situ' identification of error sources and methods of validating accuracy are emphasized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Edlén, B. (1966) · Metrologia · doi:10.1088/0026-1394/2/2/002 · Cited by 1,263
Odor Thresholds and Irritation Levels of Several Chemical Substances: A Review
RUTH, J. H. (1986) · American Industrial Hygiene Association Journal · doi:10.1080/15298668691389595 · Cited by 504
Documents Concerning the New Definition of the Metre
(1984) · Metrologia · doi:10.1088/0026-1394/19/4/004 · Cited by 216
LVIII. On the relative motion of the earth and the luminiferous Æther
Michelson, A. A., & Morley, E. W. (1887) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448708628130 · Cited by 118
Frequency stabilization of a 0633-μm He–Ne longitudinal Zeeman laser
Baer, T., Kowalski, F. V., & Hall, J. L. (1980) · Applied Optics · doi:10.1364/ao.19.003173 · Cited by 101
Frequency stability measurements on polarization-stabilized He–Ne lasers
Niebauer, T. M., Faller, J. E., Godwin, H. M., Hall, J. L., & Barger, R. L. (1988) · Applied Optics · doi:10.1364/ao.27.001285 · Cited by 94
Stabilized ^3He–^20Ne transverse Zeeman laser
Umeda, N., Tsukiji, M., & Takasaki, H. (1980) · Applied Optics · doi:10.1364/ao.19.000442 · Cited by 66
An investigation of the stability of thermistors
Wood, S. D., Mangum, B. W., Filliben, J. J., & Tillett, S. B. (1978) · Journal of Research of the National Bureau of Standards · doi:10.6028/jres.083.015 · Cited by 65
Frequency stabilization of internal mirror He–Ne lasers in a transverse magnetic field
Morris, R. H., Ferguson, J. B., & Warniak, J. S. (1975) · Applied Optics · doi:10.1364/ao.14.002808 · Cited by 38
Cited by
Rapid and precise absolute distance measurements at long range
Coddington, I., Swann, W. C., Nenadovic, L., & Newbury, N. R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.94 · Cited by 1,059
Soliton microcomb range measurement
Suh, M.-G., & Vahala, K. J. (2018) · Science · doi:10.1126/science.aao1968 · Cited by 694
Metadata
- Authors
- Bobroff, N.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1993-09-01
- Volume
- 4
- Issue
- 9
- Pages
- 907-926
- ISSN
- 0957-0233 (ISSN-L)
- OpenAlex
- W1993095842
- Cited by
- 430
- References
- 14
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advances in displacement measuring interferometry. https://app.cochat.ai/papers/10.1088/0957-0233/4/9/001
- The paper
- Bobroff, N. (1993). Recent advances in displacement measuring interferometry. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/4/9/001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.