Distortion compensation for generalized stereoscopic particle image velocimetry
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Optical distortion due to inaccurate optical alignment, lens nonlinearity, and/or refraction by optical windows, fluid interfaces, and other optical elements of an experiment causes inaccuracy by introducing variable magnification. Since fractional changes in the magnification have a one-to-one effect on the accuracy of measuring the velocity, it is important to compensate for such distortions. A general experimental calibration procedure is described which determines the magnification matrix of a distorted imaging system, and an algorithm is presented to compute accurate velocity field displacements from measurements of distorted PIV images. These procedures form a basis for generalized stereoscopic PIV procedures which permit easy electronic registration of multiple cameras and accurate recombination of stereoscopic displacement fields to obtain the three-dimensional velocity vector field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Self-citationMaas, H. G., Gruen, A., & Papantoniou, D. (1993) · Experiments in Fluids · doi:10.1007/bf00190953 · Cited by 633
Effect of resolution on the speed and accuracy of particle image velocimetry interrogation
Prasad, A. K., Adrian, R. J., Landreth, C. C., & Offutt, P. W. (1992) · Experiments in Fluids · doi:10.1007/bf00218156 · Cited by 493
Self-citationStereoscopic particle image velocimetry applied to liquid flows
Prasad, A. K., & Adrian, R. J. (1993) · Experiments in Fluids · doi:10.1007/bf00195595 · Cited by 317
Self-citationScheimpflug stereocamera for particle image velocimetry in liquid flows
Prasad, A. K., & Jensen, K. (1995) · Applied Optics · doi:10.1364/ao.34.007092 · Cited by 264
Stereoscopic particle image velocimetry
Arroyo, M. P., & Greated, C. A. (1991) · Measurement Science and Technology · doi:10.1088/0957-0233/2/12/012 · Cited by 243
Algorithms for fully automated three-dimensional particle tracking velocimetry
Guezennec, Y. G., Brodkey, R. S., Trigui, N., & Kent, J. C. (1994) · Experiments in Fluids · doi:10.1007/bf00203039 · Cited by 173
The application of an in-line, stereoscopic, PIV system to 3-component velocity measurements
Grant, I., Fu, S., Pan, X., & Wang, X. (1995) · Experiments in Fluids · doi:10.1007/bf00189710 · Cited by 28
Cited by
Twenty years of particle image velocimetry
Adrian, R. J. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0991-7 · Cited by 1,267
Self-citationTomographic particle image velocimetry
Elsinga, G. E., Scarano, F., Wieneke, B., & van Oudheusden, B. W. (2006) · Experiments in Fluids · doi:10.1007/s00348-006-0212-z · Cited by 1,251
Particle Image Velocimetry for Complex and Turbulent Flows
Westerweel, J., Elsinga, G. E., & Adrian, R. J. (2013) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-120710-101204 · Cited by 557
Self-citationRiethmuller, M., David, L., & Lecordier, B. (2012) · Laser Velocimetry in Fluid Mechanics · doi:10.1002/9781118569610.ch6 · Cited by 516
Stereo-PIV using self-calibration on particle images
Wieneke, B. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0962-z · Cited by 426
Metadata
- Authors
- Soloff, S. M., Adrian, R. J., & Liu, Z.-C.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1997-12-01
- Volume
- 8
- Issue
- 12
- Pages
- 1441-1454
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2043914165
- Cited by
- 674
- References
- 8
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.