The DOI matches its Crossref record.
Solid state gas sensors
Open accessAbstract
The detection and monitoring of gases with solid state sensors has become a well established practice. Three major types of solid state gas sensor are already in widespread use and a number of other designs currently in development may have the potential for commercial exploitation in the future. The established sensor types are reviewed here and a brief description is given of some of the emergent technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
A review of mixed-potential type zirconia-based gas sensors
Miura, N., Sato, T., Anggraini, S. A., Ikeda, H., & Zhuiykov, S. (2014) · Ionics · doi:10.1007/s11581-014-1140-1 · Cited by 334
Semiconducting Metal Oxides: SrTiO3, BaTiO3 and BaSrTiO3 in Gas-Sensing Applications: A Review
Szafraniak, B., Fuśnik, Ł., Xu, J., Gao, F., Brudnik, A., & Rydosz, A. (2021) · Coatings · doi:10.3390/coatings11020185 · Cited by 102
Metadata
- Authors
- Moseley, P. T.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1997-03-01
- Volume
- 8
- Issue
- 3
- Pages
- 223-237
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2912207476
- Cited by
- 726
- References
- 0
- FWCI
- 28.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solid state gas sensors. https://app.cochat.ai/papers/10.1088/0957-0233/8/3/003
- The paper
- Moseley, P. T. (1997). Solid state gas sensors. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/8/3/003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.