Label-free protein assay based on a nanomechanical cantilever array
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We demonstrate continuous label-free detection of two cardiac biomarker proteins (creatin kinase and myoglobin) using an array of microfabricated cantilevers functionalized with covalently anchored anti-creatin kinase and anti-myoglobin antibodies. This method allows biomarker proteins to be detected via measurement of surface stress generated by antigen–antibody molecular recognition. Reference cantilevers are used to eliminate thermal drifts, undesired chemical reactions and turbulences from injections of liquids by calculating differential deflection signals with respect to sensor cantilevers. The sensitivity achieved for myoglobin detection is below 20 µg ml −1 . Both myoglobin and creatin kinase could be detected independently using cantilevers functionalized with the corresponding antibodies, in unspecific protein background. This approach permits the use of up to seven different antigen–antibody reactions simultaneously, including an additional thermomechanical and chemical in situ reference. Applications lie in the field of early and rapid diagnosis of acute myocardial infarction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Self-citationBioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,013
Nelson, B. P., Grimsrud, T. E., Liles, M. R., Goodman, R. M., & Corn, R. M. (2001) · Analytical Chemistry · doi:10.1021/ac0010431 · Cited by 652
McKendry, R., Zhang, J., Arntz, Y., Strunz, T., Hegner, M., Lang, H. P., Baller, M. K., Certa, U., Meyer, E., Güntherodt, H.-J., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152330199 · Cited by 598
Self-citationWagner, P., Hegner, M., Kernen, P., Zaugg, F., & Semenza, G. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79810-7 · Cited by 204
Self-citationPlückthun, A. (1992) · Immunological Reviews · doi:10.1111/j.1600-065x.1992.tb01525.x · Cited by 137
Cardiac Biomarkers for Rapid Evaluation of Chest Pain
Hamm, C. W. (2001) · Circulation · doi:10.1161/circ.104.13.1454 · Cited by 59
Recent approaches in standardization of cardiac markers
Panteghini, M. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00553-8 · Cited by 20
Cited by
Systems Biology and New Technologies Enable Predictive and Preventative Medicine
Hood, L., Heath, J. R., Phelps, M. E., & Lin, B. (2004) · Science · doi:10.1126/science.1104635 · Cited by 1,108
Atomic force microscopy as a multifunctional molecular toolbox in nanobiotechnology
Müller, D. J., & Dufrêne, Y. F. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.100 · Cited by 752
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Jianrong, C., Yuqing, M., Nongyue, H., Xiaohua, W., & Sijiao, L. (2004) · Biotechnology Advances · doi:10.1016/j.biotechadv.2004.03.004 · Cited by 573
Microarray technology: beyond transcript profiling and genotype analysis
Hoheisel, J. D. (2006) · Nature Reviews Genetics · doi:10.1038/nrg1809 · Cited by 546
Metadata
- Authors
- Arntz, Y., Seelig, J. D., Lang, H. P., Zhang, J., Hunziker, P., Ramseyer, J. P., Meyer, E., Hegner, M., & Gerber, C.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2002-12-20
- Volume
- 14
- Issue
- 1
- Pages
- 86-90
- ISSN
- 0957-4484 (ISSN-L)
- OpenAlex
- W2099582861
- Cited by
- 409
- References
- 9
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.