Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 237

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Finite optical spot size and position corrections in thermal spring constant calibration

Open access
Proksch, R, Schäffer, T E, Cleveland, J P, Callahan, R C, Viani, M B · 2004 · Nanotechnology

Abstract

One of the most popular methods for calibrating the spring constant of an atomic force microscope cantilever is the thermal noise method. The usual implementation of this method has been to position the focused optical spot on or near the end of the cantilever, acquire a force curve on a hard surface to characterize the optical lever sensitivity and to then measure the thermal motion of the cantilever. The equipartition theorem then allows the spring constant to be calculated. In this work, we measured the spring constant as a function of the spot along the length of the cantilever. The observed systematic variation in the spring constant as a function of this position ranged from for a short 60 µm cantilever up to for a 225 µm cantilever we examined. In addition, the thermally calibrated spring constants systematically disagreed with spring constants calibrated using the Sader and Cleveland methods: by for the short 60 µm cantilever and by for the longest, 225 µm cantilever. By using a model that accounts for the spot diameter and position on the cantilever, the thermally measured spring constants were brought into better than 10% agreement with the other methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-4484/15/9/039

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 237

Metadata

Authors
Proksch, R., Schäffer, T. E., Cleveland, J. P., Callahan, R. C., & Viani, M. B.
Venue
Nanotechnology
Published
2004-08-14
Volume
15
Issue
9
Pages
1344-1350
ISSN
  • 0957-4484 (ISSN-L)
  • 1361-6528
OpenAlex
W2038901974
Cited by
237
References
1
FWCI
7.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Finite optical spot size and position corrections in thermal spring constant calibration. https://app.cochat.ai/papers/10.1088/0957-4484/15/9/039
The paper
Proksch, R., Schäffer, T. E., Cleveland, J. P., Callahan, R. C., & Viani, M. B. (2004). Finite optical spot size and position corrections in thermal spring constant calibration. Nanotechnology. https://doi.org/10.1088/0957-4484/15/9/039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.