Finite optical spot size and position corrections in thermal spring constant calibration
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
One of the most popular methods for calibrating the spring constant of an atomic force microscope cantilever is the thermal noise method. The usual implementation of this method has been to position the focused optical spot on or near the end of the cantilever, acquire a force curve on a hard surface to characterize the optical lever sensitivity and to then measure the thermal motion of the cantilever. The equipartition theorem then allows the spring constant to be calculated. In this work, we measured the spring constant as a function of the spot along the length of the cantilever. The observed systematic variation in the spring constant as a function of this position ranged from for a short 60 µm cantilever up to for a 225 µm cantilever we examined. In addition, the thermally calibrated spring constants systematically disagreed with spring constants calibrated using the Sader and Cleveland methods: by for the short 60 µm cantilever and by for the longest, 225 µm cantilever. By using a model that accounts for the spot diameter and position on the cantilever, the thermally measured spring constants were brought into better than 10% agreement with the other methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Reversible Unfolding of Individual Titin Immunoglobulin Domains by AFM
Rief, M., Gautel, M., Oesterhelt, F., Fernandez, J. M., & Gaub, H. E. (1997) · Science · doi:10.1126/science.276.5315.1109 · Cited by 3,077
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Adhesion Forces Between Individual Ligand-Receptor Pairs
Florin, E.-L., Moy, V. T., & Gaub, H. E. (1994) · Science · doi:10.1126/science.8153628 · Cited by 1,903
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Self-citationCalculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
Single Molecule Force Spectroscopy on Polysaccharides by Atomic Force Microscopy
Rief, M., Oesterhelt, F., Heymann, B., & Gaub, H. E. (1997) · Science · doi:10.1126/science.275.5304.1295 · Cited by 1,124
A high-speed atomic force microscope for studying biological macromolecules
Ando, T., Kodera, N., Takai, E., Maruyama, D., Saito, K., & Toda, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.211400898 · Cited by 1,102
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 4,297
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4757398 · Cited by 283
Noninvasive determination of optical lever sensitivity in atomic force microscopy
Higgins, M. J., Proksch, R., Sader, J. E., Polcik, M., Mc Endoo, S., Cleveland, J. P., & Jarvis, S. P. (2006) · Review of Scientific Instruments · doi:10.1063/1.2162455 · Cited by 239
Self-citationGarcia-Manyes, S., Oncins, G., & Sanz, F. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.064030 · Cited by 234
“avoid changes in the spring constant calculation (38).”
BackgroundRedondo-Morata, L., Giannotti, M. I., & Sanz, F. (2012) · Langmuir · doi:10.1021/la302620t · Cited by 204
Fukuma, T., & Jarvis, S. P. (2006) · Review of Scientific Instruments · doi:10.1063/1.2188867 · Cited by 193
Cook, S. M., Lang, K. M., Chynoweth, K. M., Wigton, M., Simmonds, R. W., & Schäffer, T. E. (2006) · Nanotechnology · doi:10.1088/0957-4484/17/9/010 · Cited by 186
Self-citationBiomimetic Nanowire Coatings for Next Generation Adhesive Drug Delivery Systems
Fischer, K. E., Alemán, B. J., Tao, S. L., Daniels, R. H., Li, E. M., Bünger, M. D., Nagaraj, G., Singh, P., Zettl, A., & Desai, T. A. (2009) · Nano Letters · doi:10.1021/nl803219f · Cited by 178
Effect of Temperature on the Nanomechanics of Lipid Bilayers Studied by Force Spectroscopy
Garcia-Manyes, S., Oncins, G., & Sanz, F. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.065581 · Cited by 178
“the same cantilever keeping the spot laser at the same position on the lever to avoid changes in the spring constant calculation (43).”
BackgroundThe Stiffness of Collagen Fibrils Influences Vascular Smooth Muscle Cell Phenotype
McDaniel, D. P., Shaw, G. A., Elliott, J. T., Bhadriraju, K., Meuse, C., Chung, K.-H., & Plant, A. L. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.089003 · Cited by 161
“031 N/m with an uncertainty of ;10% (27,28).”
Mullin, N., & Hobbs, J. K. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901221 · Cited by 58
Metadata
- Authors
- Proksch, R., Schäffer, T. E., Cleveland, J. P., Callahan, R. C., & Viani, M. B.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2004-08-14
- Volume
- 15
- Issue
- 9
- Pages
- 1344-1350
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2038901974
- Cited by
- 237
- References
- 32
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.