The DOI matches its Crossref record.
The determination of atomic force microscope cantilever spring constants via dimensional methods for nanomechanical analysis
Open accessAbstract
Many papers have been published on methods to determine the normal spring constant, k z , of atomic force microscope (AFM) cantilevers. This is necessary to calibrate force measurements in the AFM, which then lead to a wide variety of applications from measuring the rupture force of protein bonds to determining the Young's modulus of materials such as polymers at surfaces. Manufacturers' nominal values of k z have been found to be up a factor of two in error, therefore practical methods to calibrate k z are required. There are three main categories of methods, with some overlap, which we call: (1) dimensional, (2) static experimental and (3) dynamic experimental. Here, we consider the dimensional aspects of these methods involving the cantilever material properties and geometry. We do this via reviewing the analytical equations of seven publications and comparing them with finite element analysis (FEA) calculations. It is shown that the best analytical equations are those of Neumeister and Ducker but that these need a revision for the bending of the triangular portion of the V-shaped cantilever. This is done and the correlation with FEA is then excellent. Equations are also provided for the effect of a metallized layer and the imaging tip not being at the cantilever apex; these also agree with FEA. We evaluate the relevant uncertainties and provide recommendations as to the best equations to use together with relevant correction parameters based on the assumption that the FEA calculations are valid. We test this assumption elsewhere.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanical Properties of Collagen Fibrils
Wenger, M. P. E., Bozec, L., Horton, M. A., & Mesquida, P. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.103192 · Cited by 566
Dokukin, M. E., & Sokolov, I. (2012) · Langmuir · doi:10.1021/la302706b · Cited by 385
The applications of atomic force microscopy to vision science
Last, J. A., Russell, P., Nealey, P. F., & Murphy, C. J. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5470 · Cited by 100
Metadata
- Authors
- Clifford, C. A., & Seah, M. P.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2005-07-06
- Volume
- 16
- Issue
- 9
- Pages
- 1666-1680
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2087820727
- Cited by
- 181
- References
- 0
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The determination of atomic force microscope cantilever spring constants via dimensional methods for nanomechanical analysis. https://app.cochat.ai/papers/10.1088/0957-4484/16/9/044
- The paper
- Clifford, C. A., & Seah, M. P. (2005). The determination of atomic force microscope cantilever spring constants via dimensional methods for nanomechanical analysis. Nanotechnology. https://doi.org/10.1088/0957-4484/16/9/044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.