Practical implementation of dynamic methods for measuring atomic force microscope cantilever spring constants
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Measurement of atomic force microscope cantilever spring constants ( k ) is essential for many of the applications of this versatile instrument. Numerous techniques to measure k have been proposed. Among these, we found the thermal noise and Sader methods to be commonly applicable and relatively user-friendly, providing an in situ , non-destructive, fast measurement of k for a cantilever independent of its material or coating. Such advantages recommend these methods for widespread use. An impediment thereto is the significant complication involved in the initial implementation of the methods. Some details of the implementation are discussed in publications, while others are left unsaid. Here we present a complete, cohesive, and practically oriented discussion of the implementation of both the thermal noise and Sader methods of measuring cantilever spring constants. We review the relevant theory and discuss practical experimental means for determining the required quantities. We then present results that compare measurements of k by these two methods over nearly two orders of magnitude, and we discuss the likely origins of both statistical and systematic errors for both methods. In conclusion, we find that the two methods agree to within an average of 4% over the wide range of cantilevers measured. Given that the methods derive from distinct physics we find the agreement a compelling argument in favour of the accuracy of both, suggesting them as practical standards for the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 4,297
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Cited by
Robust microscale superlubricity in graphite/hexagonal boron nitride layered heterojunctions
Song, Y., Mandelli, D., Hod, O., Urbakh, M., Ma, M., & Zheng, Q. (2018) · Nature Materials · doi:10.1038/s41563-018-0144-z · Cited by 494
Garcia, R. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00318b · Cited by 480
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4757398 · Cited by 283
Adhesion and friction in mesoscopic graphite contacts
Koren, E., Lörtscher, E., Rawlings, C., Knoll, A. W., & Duerig, U. (2015) · Science · doi:10.1126/science.aaa4157 · Cited by 272
Imaging viscoelastic properties of live cells by AFM: power-law rheology on the nanoscale
Hecht, F. M., Rheinlaender, J., Schierbaum, N., Goldmann, W. H., Fabry, B., & Schäffer, T. E. (2015) · Soft Matter · doi:10.1039/c4sm02718c · Cited by 189
Self-citation
Metadata
- Authors
- Cook, S. M., Lang, K. M., Chynoweth, K. M., Wigton, M., Simmonds, R. W., & Schäffer, T. E.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2006-03-28
- Volume
- 17
- Issue
- 9
- Pages
- 2135-2145
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2150921736
- Cited by
- 186
- References
- 4
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.