Calibration of rectangular atomic force microscope cantilevers
Abstract
A method to determine the spring constant of a rectangular atomic force microscope cantilever is proposed that relies solely on the measurement of the resonant frequency and quality factor of the cantilever in fluid (typically air), and knowledge of its plan view dimensions. This method gives very good accuracy and improves upon the previous formulation by Sader et al. [Rev. Sci. Instrum. 66, 3789 (1995)] which, unlike the present method, requires knowledge of both the cantilever density and thickness.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The force determined by AFM cantilever deflection calibrated using the thermal noise method has an error lower than 5%.
“Similarly, the force F was determined by recording the AFM cantilever deflection during sample deformation and knowing the spring constant of the AFM cantilever, calibrated using the thermal noise method [25]. The error in force measurements using this calibration method has been shown to be lower than 5% [26].”
From Extreme strength observed in limpet teeth (2015) · cites this paper as [25]
Cited by
Sorted by citations
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458 · see citing works
Extreme strength observed in limpet teeth
Barber, A. H., Lu, D., & Pugno, N. M. (2015) · Journal of the Royal Society Interface · doi:10.1098/rsif.2014.1326 · Cited by 218 · see citing works
Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system
Li, Q., Kim, K.-S., & Rydberg, A. (2006) · Review of Scientific Instruments · doi:10.1063/1.2209953 · Cited by 208 · see citing works
Norwalk Virus Assembly and Stability Monitored by Mass Spectrometry
Shoemaker, G. K., van Duijn, E., Crawford, S. E., Uetrecht, C., Baclayon, M., Roos, W. H., Wuite, G. J. L., Estes, M. K., Prasad, B. V. V., & Heck, A. J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900620-mcp200 · Cited by 140 · see citing works
Probing the biophysical interplay between a viral genome and its capsid
Snijder, J., Uetrecht, C., Rose, R. J., Sanchez-Eugenia, R., Marti, G. A., Agirre, J., Guérin, D. M. A., Wuite, G. J. L., Heck, A. J. R., & Roos, W. H. (2013) · Nature Chemistry · doi:10.1038/nchem.1627 · Cited by 127 · see citing works
The applications of atomic force microscopy to vision science
Last, J. A., Russell, P., Nealey, P. F., & Murphy, C. J. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5470 · Cited by 100 · see citing works
Atomic-resolution three-dimensional hydration structures on a heterogeneously charged surface
Umeda, K., Zivanovic, L., Kobayashi, K., Ritala, J., Kominami, H., Spijker, P., Foster, A. S., & Yamada, H. (2017) · Nature Communications · doi:10.1038/s41467-017-01896-4 · Cited by 85 · see citing works
Optimized nanoscale composite behaviour in limpet teeth
Lu, D., & Barber, A. H. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0688 · Cited by 62 · see citing works
Probing the hydration friction of ionic interfaces at the atomic scale
Li, Z., Liu, Q., Zhang, D., Wang, Y., Zhang, Y., Li, Q., & Dong, M. (2022) · Nanoscale Horizons · doi:10.1039/d1nh00564b · Cited by 30 · see citing works
- Authors
- Sader, J. E., Chon, J. W. M., & Mulvaney, P.
- Affiliations
- The University of Melbourne (AU)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1999-10-01
- Volume
- 70
- Issue
- 10
- Pages
- 3967-3969
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2082877303
- Cited by
- 2,145
- References
- 0
- Citations by year
- 2026: 72 · 2025: 68 · 2024: 81 · 2023: 80 · 2022: 84 · 2021: 95 · 2020: 113 · 2019: 108 · 2018: 108 · 2017: 110 · 2016: 100 · 2015: 104 · 2014: 102 · 2013: 122 · 2012: 125
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Keywords
- rectangular cantilever, atomic force microscopy, resonant frequency, quality factor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review