Nearly complete regression of tumors via collective behavior of magnetic nanoparticles in hyperthermia
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
One potential cancer treatment selectively deposits heat to the tumor through activation of magnetic nanoparticles inside the tumor. This can damage or kill the cancer cells without harming the surrounding healthy tissue. The properties assumed to be most important for this heat generation (saturation magnetization, amplitude and frequency of external magnetic field) originate from theoretical models that assume non-interacting nanoparticles. Although these factors certainly contribute, the fundamental assumption of 'no interaction' is flawed and consequently fails to anticipate their interactions with biological systems and the resulting heat deposition. Experimental evidence demonstrates that for interacting magnetite nanoparticles, determined by their spacing and anisotropy, the resulting collective behavior in the kilohertz frequency regime generates significant heat, leading to nearly complete regression of aggressive mammary tumors in mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical mechanics of chain molecules
Flory, P. J., & Volkenstein, M. (1969) · Biopolymers · doi:10.1002/bip.1969.360080514 · Cited by 6,427
Opsonization, biodistribution, and pharmacokinetics of polymeric nanoparticles
OWENSIII, D., & PEPPAS, N. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.10.010 · Cited by 3,637
Heating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Reduction and analysis of SANS and USANS data using IGOR Pro
Kline, S. R. (2006) · Journal of Applied Crystallography · doi:10.1107/s0021889806035059 · Cited by 1,862
The cellular and molecular basis of hyperthermia
Hildebrandt, B. (2002) · Critical Reviews in Oncology/Hematology · doi:10.1016/s1040-8428(01)00179-2 · Cited by 1,718
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Heating the patient: a promising approach?
van der Zee, J. (2002) · Annals of Oncology · doi:10.1093/annonc/mdf280 · Cited by 1,220
Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
Dewhirst, M. W., Viglianti, B. L., Lora-Michiels, M., Hanson, M., & Hoopes, P. J. (2003) · International Journal of Hyperthermia · doi:10.1080/0265673031000119006 · Cited by 1,014
Self-citationTargeted pharmaceutical nanocarriers for cancer therapy and imaging
Torchilin, V. P. (2007) · The AAPS Journal · doi:10.1208/aapsj0902015 · Cited by 762
Gupta, A. K., Naregalkar, R. R., Vaidya, V. D., & Gupta, M. (2007) · Nanomedicine · doi:10.2217/17435889.2.1.23 · Cited by 708
Tsuji, J. S., Maynard, A. D., Howard, P. C., James, J. T., Lam, C.-W., Warheit, D. B., & Santamaria, A. B. (2006) · Toxicological Sciences · doi:10.1093/toxsci/kfi339 · Cited by 474
Statistical mechanics of chain molecules
Volkenstein, M. (1970) · Biopolymers · doi:10.1002/bip.1970.360090311 · Cited by 446
Johannsen, M., Gneveckow, U., Taymoorian, K., Thiesen, B., Waldöfner, N., Scholz, R., Jung, K., Jordan, A., Wust, P., & Loening, S. A. (2007) · International Journal of Hyperthermia · doi:10.1080/02656730601175479 · Cited by 382
Bourrinet, P., Bengele, H. H., Bonnemain, B., Dencausse, A., Idee, J.-M., Jacobs, P. M., & Lewis, J. M. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000197669.80475.dd · Cited by 339
Functionalized Magnetite Nanoparticles—Synthesis, Properties, and Bio-Applications
Majewski, P., & Thierry, B. (2007) · Critical Reviews in Solid State and Materials Sciences · doi:10.1080/10408430701776680 · Cited by 289
Metallic Iron Nanoparticles for MRI Contrast Enhancement and Local Hyperthermia
Hadjipanayis, C. G., Bonder, M. J., Balakrishnan, S., Wang, X., Mao, H., & Hadjipanayis, G. C. (2008) · Small · doi:10.1002/smll.200800261 · Cited by 286
Design and performance of a thermal-neutron double-crystal diffractometer for USANS at NIST
Barker, J. G., Glinka, C. J., Moyer, J. J., Kim, M. H., Drews, A. R., & Agamalian, M. (2005) · Journal of Applied Crystallography · doi:10.1107/s0021889805032103 · Cited by 225
DeNardo, S. J., DeNardo, G. L., Miers, L. A., Natarajan, A., Foreman, A. R., Gruettner, C., Adamson, G. N., & Ivkov, R. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-1004-0022 · Cited by 200
Self-citationIvkov, R., DeNardo, S. J., Daum, W., Foreman, A. R., Goldstein, R. C., Nemkov, V. S., & DeNardo, G. L. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-1004-0016 · Cited by 186
Self-citationSpin disorder and magnetic anisotropy in Fe3O4 nanoparticles
Lima, E., Brandl, A. L., Arelaro, A. D., & Goya, G. F. (2006) · Journal of Applied Physics · doi:10.1063/1.2191471 · Cited by 184
Use of magnetic nanoparticle heating in the treatment of breast cancer
Hilger, I., Hergt, R., & Kaiser, W. A. (2005) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20055018 · Cited by 170
Grüttner, C., Müller, K., Teller, J., Westphal, F., Foreman, A. R., & Ivkov, R. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.10.1151 · Cited by 162
Self-citationDeNardo, S. J., DeNardo, G. L., Natarajan, A., Miers, L. A., Foreman, A. R., Gruettner, C., Adamson, G. N., & Ivkov, R. (2007) · PubMed · Cited by 143
Self-citationMagnetic-Field-Induced Assemblies of Cobalt Nanoparticles
Cheng, G., Romero, D. B., Fraser, G. T., & Walker, A. R. H. (2005) · Langmuir · doi:10.1021/la0506473 · Cited by 141
Thermoregulatory responses to RF energy absorption
Adair, E. R., & Black, D. R. (2003) · Bioelectromagnetics · doi:10.1002/bem.10133 · Cited by 117
NanoFerrite Particle Based Radioimmunonanoparticles: Binding Affinity and In Vivo Pharmacokinetics
Natarajan, A., Gruettner, C., Ivkov, R., DeNardo, G. L., Mirick, G., Yuan, A., Foreman, A., & DeNardo, S. J. (2008) · Bioconjugate Chemistry · doi:10.1021/bc800015n · Cited by 111
Self-citationSize and Concentration Effects on High Frequency Hysteresis of Iron Oxide Nanoparticles
Eggeman, A. S., Majetich, S. A., Farrell, D. F., & Pankhurst, Q. A. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.894127 · Cited by 106
Dennis, C. L., Jackson, A., Borchers, J. A., Ivkov, R., Foreman, A. R., Lau, J. W., Goernitz, E., & Gruettner, C. (2008) · Journal of Applied Physics · doi:10.1063/1.2837647 · Cited by 105
Self-citationDeNardo, G. L., Natarajan, A., Hok, S., Perkins, J., Cosman, M., DeNardo, S. J., Lightstone, F. C., Mirick, G. R., Miers, L. A., & Balhorn, R. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.041095 · Cited by 102
Particle size effect on phase and magnetic properties of polymer-coated magnetic nanoparticles
Balakrishnan, S., Bonder, M. J., & Hadjipanayis, G. C. (2008) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2008.08.055 · Cited by 82
Magnetic anisotropy in Fe3O4—PVA nanocomposites as a result of Fe3O4-nanoparticles chains formation
Андреевна, Н. А., Smirnov, E. V., & Gendler, T. S. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.10.119 · Cited by 23
Intratumoral iron oxide nanoparticle hyperthermia and radiation cancer treatment
Hoopes, P. J., Strawbridge, R. R., Gibson, U. J., Zeng, Q., Pierce, Z. E., Savellano, M. D., Tate, J. A., Ogden, J., Baker, I. A., Ivkov, R., et al. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.706302 · Cited by 16
Self-citation
Cited by
The big picture on nanomedicine: the state of investigational and approved nanomedicine products
Etheridge, M. L., Campbell, S. A., Erdman, A. G., Haynes, C. L., Wolf, S. M., & McCullough, J. (2013) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2012.05.013 · Cited by 1,088
“Iron oxide particles are used in MR contrast(79,80) and cancer thermal therapies.(75,81) Colloidal gold is being used in systemic delivery of therapeutic biologicals(82) and for cancer thermal therapies.”
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
Heating efficiency in magnetic nanoparticle hyperthermia
Deatsch, A. E., & Evans, E. E. (2014) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2013.11.006 · Cited by 811
Martinez-Boubeta, C., Simeonidis, K., Makridis, A., Angelakeris, M., Iglesias, O., Guardia, P., Cabot, A., Yedra, L., Estradé, S., Peiró, F., et al. (2013) · Scientific Reports · doi:10.1038/srep01652 · Cited by 539
Magnetic particle hyperthermia—a promising tumour therapy?
Dutz, S., & Hergt, R. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/45/452001 · Cited by 525
Metadata
- Authors
- Dennis, C. L., Jackson, A. J., Borchers, J. A., Hoopes, P. J., Strawbridge, R., Foreman, A. R., van Lierop, J., Grüttner, C., & Ivkov, R.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2009-09-03
- Volume
- 20
- Issue
- 39
- Pages
- 395103
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2003581316
- Cited by
- 254
- References
- 32
- FWCI
- 8.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.