Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 342

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Molecular-receptor-specific, non-toxic, near-infrared-emitting Au cluster-protein nanoconjugates for targeted cancer imaging

Open access
Retnakumari, Archana, Setua, Sonali, Menon, Deepthy, Ravindran, Prasanth, Muhammed, Habeeb, Pradeep, Thalappil, Nair, Shantikumar, Koyakutty, Manzoor·2010·Nanotechnology

Abstract

Molecular-receptor-targeted imaging of folate receptor positive oral carcinoma cells using folic-acid-conjugated fluorescent Au(25) nanoclusters (Au NCs) is reported. Highly fluorescent Au(25) clusters were synthesized by controlled reduction of Au(+) ions, stabilized in bovine serum albumin (BSA), using a green-chemical reducing agent, ascorbic acid (vitamin-C). For targeted-imaging-based detection of cancer cells, the clusters were conjugated with folic acid (FA) through amide linkage with the BSA shell. The bioconjugated clusters show excellent stability over a wide range of pH from 4 to 14 and fluorescence efficiency of approximately 5.7% at pH 7.4 in phosphate buffer saline (PBS), indicating effective protection of nanoclusters by serum albumin during the bioconjugation reaction and cell-cluster interaction. The nanoclusters were characterized for their physico-chemical properties, toxicity and cancer targeting efficacy in vitro. X-ray photoelectron spectroscopy (XPS) suggests binding energies correlating to metal Au 4f(7/2) approximately 83.97 eV and Au 4f(5/2) approximately 87.768 eV. Transmission electron microscopy and atomic force microscopy revealed the formation of individual nanoclusters of size approximately 1 nm and protein cluster aggregates of size approximately 8 nm. Photoluminescence studies show bright fluorescence with peak maximum at approximately 674 nm with the spectral profile covering the near-infrared (NIR) region, making it possible to image clusters at the 700-800 nm emission window where the tissue absorption of light is minimum. The cell viability and reactive oxygen toxicity studies indicate the non-toxic nature of the Au clusters up to relatively higher concentrations of 500 microg ml(-1). Receptor-targeted cancer detection using Au clusters is demonstrated on FR(+ve) oral squamous cell carcinoma (KB) and breast adenocarcinoma cell MCF-7, where the FA-conjugated Au(25) clusters were found internalized in significantly higher concentrations compared to the negative control cell lines. This study demonstrates the potential of using non-toxic fluorescent Au nanoclusters for the targeted imaging of cancer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-4484/21/5/055103

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 342

Metadata

Authors
Retnakumari, A., Setua, S., Menon, D., Ravindran, P., Muhammed, H., Pradeep, T., Nair, S., & Koyakutty, M.
Venue
Nanotechnology
Published
2009-12-21
Volume
21
Issue
5
Pages
055103
ISSN
  • 0957-4484 (ISSN-L)
  • 1361-6528
OpenAlex
W2104348641
Cited by
342
References
32
FWCI
11.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Molecular-receptor-specific, non-toxic, near-infrared-emitting Au cluster-protein nanoconjugates for targeted cancer imaging. https://app.cochat.ai/papers/10.1088/0957-4484/21/5/055103
The paper
Retnakumari, A., Setua, S., Menon, D., Ravindran, P., Muhammed, H., Pradeep, T., Nair, S., & Koyakutty, M. (2010). Molecular-receptor-specific, non-toxic, near-infrared-emitting Au cluster-protein nanoconjugates for targeted cancer imaging. Nanotechnology. https://doi.org/10.1088/0957-4484/21/5/055103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.