The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Intrinsically stretchable transparent electrodes based on silver-nanowire–crosslinked-polyacrylate composites
Abstract
Stretchable transparent composites have been synthesized consisting of a silver nanowire (AgNW) network embedded in the surface layer of a crosslinked poly(acrylate) matrix. The interpenetrating networks of AgNWs and the crosslinked polymer matrix lead to high surface conductivity, high transparency, and rubbery elasticity. The presence of carboxylic acid groups on the polymer chains enhances the bonding between AgNWs and the polymer matrix, and further increases the stretchability of the composites. The sheet resistance of the composite electrode increases by only 2.3 times at 50% strain. Repeated stretching to 50% strain and relaxation only causes a small increase of the sheet resistance after 600 cycles. The morphology of the composites during reversible stretching and relaxation has been investigated to expound the conductivity changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Silver nanowire-polymer composite electrodes for efficient polymer solar cells
Yu, Z., Li, L., Zhang, Q., Hu, W., & Pei, Q. (2011) · Advanced Materials · doi:10.1002/adma.201101992 · Cited by 352
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Stretchable, Transparent, Ionic Conductors
Keplinger, C., Sun, J.-Y., Foo, C. C., Rothemund, P., Whitesides, G. M., & Suo, Z. (2013) · Science · doi:10.1126/science.1240228 · Cited by 1,754
Elastomeric polymer light-emitting devices and displays
Liang, J., Li, L., Niu, X., Yu, Z., & Pei, Q. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.242 · Cited by 973
Self-citationWearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
Recent Progress on Stretchable Electronic Devices with Intrinsically Stretchable Components
Trung, T. Q., & Lee, N. (2017) · Advanced Materials · doi:10.1002/adma.201603167 · Cited by 497
Metadata
- Authors
- Hu, W., Niu, X., Li, L., Yun, S., Yu, Z., & Pei, Q.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2012-08-10
- Volume
- 23
- Issue
- 34
- Pages
- 344002
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2039659572
- Cited by
- 191
- References
- 1
- FWCI
- 11.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intrinsically stretchable transparent electrodes based on silver-nanowire–crosslinked-polyacrylate composites. https://app.cochat.ai/papers/10.1088/0957-4484/23/34/344002
- The paper
- Hu, W., Niu, X., Li, L., Yun, S., Yu, Z., & Pei, Q. (2012). Intrinsically stretchable transparent electrodes based on silver-nanowire–crosslinked-polyacrylate composites. Nanotechnology. https://doi.org/10.1088/0957-4484/23/34/344002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.