Abstract
This paper describes a method for fabricating microfluidic devices in a photodefinable epoxy (SU-8). This technique is compatible with, and complementary to, conventional fabrication techniques. It allows microstructures formed in SU-8 to be bonded to produce sealed microfluidic channels. A micromixer fabricated entirely in SU-8, using this technique, for performing liquid-phase reactions is shown to be suitable for visible spectroscopy. This fabrication method also allows the incorporation of materials that are often difficult to integrate. By fabricating hybrid devices that incorporate quartz windows, we demonstrate that these devices are compatible with organic solvents and that in situ ultraviolet detection in a microfluidic system is possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
SU-8: a low-cost negative resist for MEMS
Lorenz, H., Despont, M., Fahrni, N., LaBianca, N., Renaud, P., & Vettiger, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/010 · Cited by 979
High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Negative photoresists for optical lithography
Shaw, J. M., Gelorme, J. D., LaBianca, N. C., Conley, W. E., & Holmes, S. J. (1997) · IBM Journal of Research and Development · doi:10.1147/rd.411.0081 · Cited by 345
Rapid prototyping of complex structures with feature sizes larger than 20 μm
Qin, D., Xia, Y., & Whitesides, G. M. (1996) · Advanced Materials · doi:10.1002/adma.19960081110 · Cited by 269 · cited 2×
“rapid prototyping method we used to make the masks [ 21 ].”
MethodRoom-Temperature Imprinting Method for Plastic Microchannel Fabrication
Xu, J., Locascio, L. E., Gaitan, M., & Lee, C. S. (2000) · Analytical Chemistry · doi:10.1021/ac991216q · Cited by 177 · cited 1×
“Many replication techniques exist for forming plastics at the microscale: embossing [5]; casting [6]; injection molding [7]; and imprinting [ 8 ].”
BackgroundSimple and low cost fabrication of embedded micro-channels by using a new thick-film photoplastic
Guérin, L., Bossel, M., Demierre, M., Calmes, S., & Renaud, P. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1997.635730 · Cited by 146
Buried microchannels in photopolymer for delivering of solutions to neurons in a network
Heuschkel, M. O., Guérin, L., Buisson, B., Bertrand, D., & Renaud, P. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00071-9 · Cited by 109
Cited by
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Chemistry in Microstructured Reactors
Jähnisch, K., Hessel, V., Löwe, H., & Baerns, M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300577 · Cited by 1,286
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Metadata
- Authors
- Jackman, R. J., Floyd, T. M., Ghodssi, R., Schmidt, M. A., & Jensen, K. F.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2001-04-20
- Volume
- 11
- Issue
- 3
- Pages
- 263-269
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2000186646
- Cited by
- 220
- References
- 8
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.