The DOI matches its Crossref record.
Development of polyimide flexible tactile sensor skin
Abstract
We present the development of a polyimide-based two-dimensional tactile sensing array realized using a novel inverted fabrication technique. Thermal silicon oxide or Pyrex® substrates are treated such that their surfaces are OH group terminated, allowing good adhesion between such substrates and a spun-on polyimide film during processing through what are suspected to be hydrogen bonds that can be selectively broken when release is desired. The release of the continuous polyimide film is rapidly accomplished by breaking these bonds. This process results in robust, low-cost and continuous polymer-film devices. The developed sensor skin contains an array of membrane-based tactile sensors (taxels). Micromachined thin-film metal strain gauges are positioned on the edges of polyimide membranes. The change in resistance from each strain gauge resulting from normal forces applied to tactile bumps on the top of the membranes is used to image force distribution. Response of an individual taxel is characterized. The effective gauge factor of the taxels is found to be approximately 1.3. Sensor array output is experimentally obtained. The demonstrated devices are robust enough for direct contact with humans, everyday objects and contaminants without undue care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tactile sensing for dexterous in-hand manipulation in robotics—A review
Yousef, H., Boukallel, M., & Althoefer, K. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.038 · Cited by 784
Kim, D.-H., Lu, N., Ghaffari, R., Kim, Y.-S., Lee, S. P., Xu, L., Wu, J., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 770
The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies
Ward-Cherrier, B., Pestell, N., Cramphorn, L., Winstone, B., Giannaccini, M. E., Rossiter, J., & Lepora, N. F. (2018) · Soft Robotics · doi:10.1089/soro.2017.0052 · Cited by 587
Flexible Organic Electronics in Biology: Materials and Devices
Liao, C., Zhang, M., Yao, M. Y., Hua, T., Li, L., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201402625 · Cited by 438
A Flexible Polymer Tactile Sensor: Fabrication and Modular Expandability for Large Area Deployment
Lee, H.-K., Chang, S.-I., & Yoon, E. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.886021 · Cited by 396
Metadata
- Authors
- Engel, J., Chen, J., & Liu, C.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2003-02-24
- Volume
- 13
- Issue
- 3
- Pages
- 359-366
- ISSN
- 0960-1317 (ISSN-L)
- OpenAlex
- W2157459335
- Cited by
- 291
- References
- 0
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of polyimide flexible tactile sensor skin. https://app.cochat.ai/papers/10.1088/0960-1317/13/3/302
- The paper
- Engel, J., Chen, J., & Liu, C. (2003). Development of polyimide flexible tactile sensor skin. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/13/3/302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.