The DOI matches its Crossref record.
PMMA to SU-8 bonding for polymer based lab-on-a-chip systems with integrated optics
Open accessAbstract
An adhesive bonding technique for wafer-level sealing of SU-8 based lab-on-a-chip microsystems with integrated optical components is presented. Microfluidic channels and optical components, e.g. waveguides, are fabricated in cross-linked SU-8 and sealed with a Pyrex glass substrate by means of an intermediate layer of 950k molecular weight poly-methylmethacrylate (PMMA). Due to a lower refractive index of PMMA ( n = 1.49 at λ = 600–900 nm) this bonding technique preserves waveguiding in the cross-linked SU-8 structures ( n = 1.59 at λ = 633 nm) in combination with good sealing of the microfluidic channels. The bonding strength dependence on bonding temperature and bonding force is investigated. A maximum bonding strength of 16 MPa is achieved at bonding temperatures between 110 °C and 120 °C, at a bonding force of 2000 N on a 4 inch wafer. The optical propagation loss of multi-mode 10 µm (thickness) × 30 µm (width) SU-8 waveguides is measured. The propagation loss in PMMA bonded waveguide structures is more than 5 dB cm −1 lower, at wavelengths between 600 nm and 900 nm, than in similar structures bonded by an intermediate layer of SU-8. Furthermore 950k PMMA shows no tendency to flow into the bonded structures during bonding because of its high viscosity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Niklaus, F., Stemme, G., Lu, J. Q., & Gutmann, R. J. (2006) · Journal of Applied Physics · doi:10.1063/1.2168512 · Cited by 472
Cyclic olefin polymers: emerging materials for lab-on-a-chip applications
Nunes, P. S., Ohlsson, P. D., Ordeig, O., & Kutter, J. P. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0605-4 · Cited by 434
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Polymer Fiber Probes Enable Optical Control of Spinal Cord and Muscle Function In Vivo
Lu, C., Froriep, U. P., Koppes, R. A., Canales, A., Caggiano, V., Selvidge, J., Bizzi, E., & Anikeeva, P. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201401266 · Cited by 85
Metadata
- Authors
- Bilenberg, B., Nielsen, T., Clausen, B., & Kristensen, A.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2004-04-20
- Volume
- 14
- Issue
- 6
- Pages
- 814-818
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2035757080
- Cited by
- 166
- References
- 0
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PMMA to SU-8 bonding for polymer based lab-on-a-chip systems with integrated optics. https://app.cochat.ai/papers/10.1088/0960-1317/14/6/008
- The paper
- Bilenberg, B., Nielsen, T., Clausen, B., & Kristensen, A. (2004). PMMA to SU-8 bonding for polymer based lab-on-a-chip systems with integrated optics. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/14/6/008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.