A magnetically driven PDMS micropump with ball check-valves
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
In this paper, we present a low-cost, PDMS-membrane micropump with two one-way ball check-valves for lab-on-a-chip and microfluidic applications. The micropump consists of two functional PDMS layers, one holding the ball check-valves and an actuating chamber, and the other covering the chamber and holding a miniature permanent magnet on top for actuation. An additional PDMS layer is used to cover the top magnet, and thereby encapsulate the entire device. A simple approach was used to assemble a high-performance ball check-valve using a micropipette and heat shrink tubing. The micropump can be driven by an external magnetic force provided by another permanent magnet or an integrated coil. In the first driving scheme, a small do motor (6 mm in diameter and 15 mm in length) with a neodymium-iron-boron permanent magnet embedded in its shaft was used to actuate the membrane-mounted magnet. This driving method yielded a large pumping rate with very low power consumption. A maximum pumping rate of 774 μ L min(-1) for deionized water was achieved at the input power of 13 mW, the highest pumping rate reported in the literature for micropumps at such power consumptions. Alternatively, we actuated the micropump with a 10-turn planar coil fabricated on a PC board. This method resulted in a higher pumping rate of 1 mL min(-1) for deionized water. Although more integratable and compact, the planar microcoil driving technique has a much higher power consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Micromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
Jo, B.-H., Van Lerberghe, L. M., Motsegood, K. M., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825780 · Cited by 1,098
A ferrofluidic magnetic micropump
Hatch, A., Kamholz, A. E., Holman, G., Yager, P., & Bohringer, K. F. (2001) · Journal of Microelectromechanical Systems · doi:10.1109/84.925748 · Cited by 339
Micro magnetic silicone elastomer membrane actuator
Khoo, M., & Liu, C. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(00)00559-8 · Cited by 194
Micropumps: summarizing the first two decades
Woias, P. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.443069 · Cited by 86 · cited 3×
“Bartels mP5 [15] Positive Plastic polyphenyl 18 × 15 × 3 mm3 50–3000 μl min−1 50 kPa 45 mW displacement sulphon ThinXXS MDP1304 [16] Positive Metal and plastic 26 × 25 × 13 mm3 6.”
BackgroundMethodInfluentialModelling of micropumps using unimorph piezoelectric actuator and ball valves
Accoto, D., Carrozza, M. C., & Dario, P. (2000) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/10/2/329 · Cited by 51
Cited by
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
MEMS-based micropumps in drug delivery and biomedical applications
Nisar, A., Afzulpurkar, N., Mahaisavariya, B., & Tuantranont, A. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.064 · Cited by 614
Current micropump technologies and their biomedical applications
Amirouche, F., Zhou, Y., & Johnson, T. (2009) · Microsystem Technologies · doi:10.1007/s00542-009-0804-7 · Cited by 332
Recent trends in mechanical micropumps and their applications: A review
Mohith, S., Karanth, P. N., & Kulkarni, S. M. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.04.009 · Cited by 188
Micro-fluidic actuation using magnetic artificial cilia
Fahrni, F., Prins, M. W. J., & van IJzendoorn, L. J. (2009) · Lab on a Chip · doi:10.1039/b908578e · Cited by 169
Yoo, J., Chung, G., & Park, Y. (2025) · Advanced Materials · doi:10.1002/adma.202419504 · Cited by 13
Metadata
- Authors
- Pan, T., McDonald, S. J., Kai, E. M., & Ziaie, B.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2005-03-31
- Volume
- 15
- Issue
- 5
- Pages
- 1021-1026
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2076096431
- Cited by
- 164
- References
- 9
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.